You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
224 lines
5.8 KiB
224 lines
5.8 KiB
//=========== (C) Copyright 2015 Valve, L.L.C. All rights reserved. ===========
|
|
//
|
|
// The copyright to the contents herein is the property of Valve, L.L.C.
|
|
// The contents may be used and/or copied only with the written permission of
|
|
// Valve, L.L.C., or in accordance with the terms and conditions stipulated in
|
|
// the agreement/contract under which the contents have been supplied.
|
|
//
|
|
// Shares dynamic loading of COM/ole32/oleaut32 out of tier0.
|
|
//=============================================================================
|
|
|
|
#include "tier0/platform_com.h"
|
|
#include "tier0/threadtools.h"
|
|
|
|
#ifdef PLATFORM_WINDOWS
|
|
|
|
typedef int32 ThreadInitOnce_t;
|
|
typedef class CSysModule* PlatModule_t;
|
|
#define PLAT_MODULE_INVALID ( (PlatModule_t)0 )
|
|
|
|
static PlatCOMFunctions_t g_COMFunctions;
|
|
static PlatModule_t g_hCOM;
|
|
static ThreadInitOnce_t g_COMFunctionsInit;
|
|
|
|
static const char *g_COMFunctionNames[] =
|
|
{
|
|
"CoInitializeEx",
|
|
"CoUninitialize",
|
|
"CoCreateInstance",
|
|
"CoTaskMemAlloc",
|
|
"CoTaskMemRealloc",
|
|
"CoTaskMemFree",
|
|
};
|
|
|
|
enum PlatGetProcAddressesFlags_t
|
|
{
|
|
k_nPlatGetProcAddresses_Default = 0x00000000,
|
|
k_nPlatGetProcAddresses_Optional = 0x00000001,
|
|
};
|
|
|
|
// Plat_GetProcAddresses copied from Source2 platform.cpp
|
|
// Added here to avoid changing platform.h...
|
|
void *Plat_GetProcAddresses( const char *pModuleName,
|
|
int nNames,
|
|
const char **pNames,
|
|
size_t nTotalPointerBytes,
|
|
void *pPointers,
|
|
size_t nTotalFlagsBytes,
|
|
uint32 *pFlags,
|
|
bool bFailFatal )
|
|
{
|
|
if ( (nTotalPointerBytes & (sizeof( void* ) - 1)) != 0 )
|
|
{
|
|
Plat_FatalError( "%s: invalid pointer byte count\n", __FUNCTION__ );
|
|
}
|
|
if ( (size_t)nNames != nTotalPointerBytes / sizeof( void* ) )
|
|
{
|
|
Plat_FatalError( "%s: different number of names and pointers\n", __FUNCTION__ );
|
|
}
|
|
if ( (nTotalFlagsBytes & (sizeof( *pFlags ) - 1)) != 0 )
|
|
{
|
|
Plat_FatalError( "%s: invalid flag byte count\n", __FUNCTION__ );
|
|
}
|
|
if ( pFlags )
|
|
{
|
|
if ( (size_t)nNames != nTotalFlagsBytes / sizeof( *pFlags ) )
|
|
{
|
|
Plat_FatalError( "%s: different number of names and flags\n", __FUNCTION__ );
|
|
}
|
|
}
|
|
|
|
HMODULE hModule = ::LoadLibrary( pModuleName );
|
|
if ( hModule == 0 )
|
|
{
|
|
if ( bFailFatal )
|
|
{
|
|
int nErr = GetLastError();
|
|
Plat_FatalError( "%s: unable to load '%s', error %d\n", __FUNCTION__, pModuleName, nErr );
|
|
}
|
|
|
|
return NULL;
|
|
}
|
|
|
|
void** pFunc = (void**)pPointers;
|
|
for ( int i = 0; i < nNames; i++ )
|
|
{
|
|
uint32 nFlags = pFlags ? pFlags[i] : 0;
|
|
*pFunc = ::GetProcAddress( hModule, pNames[i] );
|
|
if ( !*pFunc &&
|
|
(nFlags & k_nPlatGetProcAddresses_Optional) == 0 )
|
|
{
|
|
if ( bFailFatal )
|
|
{
|
|
Plat_FatalError( "%s: unable to find %s in '%s'\n", __FUNCTION__, pNames[i], pModuleName );
|
|
}
|
|
|
|
::FreeLibrary( hModule );
|
|
memset( pPointers, 0, nTotalPointerBytes );
|
|
return NULL;
|
|
}
|
|
|
|
pFunc++;
|
|
}
|
|
|
|
return hModule;
|
|
}
|
|
|
|
static bool Plat_LoadCOM_Once( ThreadInitOnce_t *pMarker )
|
|
{
|
|
const char *pCOMName = "ole32.dll";
|
|
g_hCOM = (PlatModule_t)Plat_GetProcAddresses( pCOMName,
|
|
ARRAYSIZE( g_COMFunctionNames ),
|
|
g_COMFunctionNames,
|
|
sizeof( g_COMFunctions ),
|
|
&g_COMFunctions,
|
|
0,
|
|
NULL,
|
|
false );
|
|
// We always succeed in this routine as we
|
|
// handle failure at a higher level.
|
|
return true;
|
|
}
|
|
|
|
PlatCOMFunctions_t *Plat_LoadCOM()
|
|
{
|
|
ThreadInitOnceCall( &g_COMFunctionsInit, Plat_LoadCOM_Once );
|
|
return &g_COMFunctions;
|
|
}
|
|
|
|
PlatCOMFunctions_t *Plat_CheckCOM()
|
|
{
|
|
if ( g_hCOM == PLAT_MODULE_INVALID )
|
|
{
|
|
return NULL;
|
|
}
|
|
|
|
return &g_COMFunctions;
|
|
}
|
|
|
|
PlatCOMFunctions_t *Plat_RequireCOM()
|
|
{
|
|
if ( g_hCOM == PLAT_MODULE_INVALID )
|
|
{
|
|
Plat_FatalError( "Unable to load COM\n" );
|
|
}
|
|
|
|
return &g_COMFunctions;
|
|
}
|
|
|
|
void Plat_UnloadCOM()
|
|
{
|
|
// We do not unload COM currently but we have a stub
|
|
// that callers should use so that we can drop in unloading
|
|
// if we need it in the future.
|
|
}
|
|
|
|
static PlatOleAutFunctions_t g_OleAutFunctions;
|
|
static PlatModule_t g_hOleAut;
|
|
static ThreadInitOnce_t g_OleAutFunctionsInit;
|
|
|
|
static const char *g_OleAutFunctionNames[] =
|
|
{
|
|
"VariantInit",
|
|
"VariantClear",
|
|
"VariantCopy",
|
|
"SysAllocString",
|
|
"SysAllocStringByteLen",
|
|
"SysAllocStringLen",
|
|
"SysFreeString",
|
|
"SysReAllocString",
|
|
"SysReAllocStringLen",
|
|
"SysStringByteLen",
|
|
"SysStringLen",
|
|
};
|
|
|
|
static bool Plat_LoadOleAut_Once( ThreadInitOnce_t *pMarker )
|
|
{
|
|
const char *pOleAutName = "oleaut32.dll";
|
|
g_hOleAut = (PlatModule_t)Plat_GetProcAddresses( pOleAutName,
|
|
ARRAYSIZE( g_OleAutFunctionNames ),
|
|
g_OleAutFunctionNames,
|
|
sizeof( g_OleAutFunctions ),
|
|
&g_OleAutFunctions,
|
|
0,
|
|
NULL,
|
|
false );
|
|
// We always succeed in this routine as we
|
|
// handle failure at a higher level.
|
|
return true;
|
|
}
|
|
|
|
PlatOleAutFunctions_t *Plat_LoadOleAut()
|
|
{
|
|
ThreadInitOnceCall( &g_OleAutFunctionsInit, Plat_LoadOleAut_Once );
|
|
return &g_OleAutFunctions;
|
|
}
|
|
|
|
PlatOleAutFunctions_t *Plat_CheckOleAut()
|
|
{
|
|
if ( g_hOleAut == PLAT_MODULE_INVALID )
|
|
{
|
|
return NULL;
|
|
}
|
|
|
|
return &g_OleAutFunctions;
|
|
}
|
|
|
|
PlatOleAutFunctions_t *Plat_RequireOleAut()
|
|
{
|
|
if ( g_hOleAut == PLAT_MODULE_INVALID )
|
|
{
|
|
Plat_FatalError( "Unable to load oleaut32\n" );
|
|
}
|
|
|
|
return &g_OleAutFunctions;
|
|
}
|
|
|
|
void Plat_UnloadOleAut()
|
|
{
|
|
// We do not unload oleaut32 currently but we have a stub
|
|
// that callers should use so that we can drop in unloading
|
|
// if we need it in the future.
|
|
}
|
|
|
|
#endif // #ifdef PLATFORM_WINDOWS
|