Copyright (c) 1992 Microsoft Corporation
|
|
|
|
Module Name:
|
|
|
|
ltreg.c
|
|
|
|
Abstract:
|
|
|
|
This module contains helper routines for reading configuration
|
|
information from the registry.
|
|
|
|
Author:
|
|
|
|
Nikhil Kamkolkar ([email protected])
|
|
Stephen Hou ([email protected])
|
|
|
|
Revision History:
|
|
19 Jun 1992 Initial Version ([email protected])
|
|
|
|
Notes: Tab stop: 4
|
|
--*/
|
|
|
|
#define LTREG_H_LOCALS
|
|
#include "ltmain.h"
|
|
#include "ltreg.h"
|
|
|
|
// Define file id for errorlogging
|
|
#define FILENUM LTREG
|
|
|
|
|
|
UINT
|
|
LtRegGetBusNumber(
|
|
IN NDIS_HANDLE ConfigHandle
|
|
)
|
|
/*++
|
|
|
|
Routine Description:
|
|
|
|
This routine determines the bus number the card is installed on
|
|
|
|
Arguments:
|
|
|
|
ConfigHandle : The handle to the configuration database
|
|
|
|
Return Value:
|
|
|
|
Returns the bus number the card is on. If we do not find the
|
|
relevant information in the database, then 0 is returned.
|
|
|
|
--*/
|
|
{
|
|
NDIS_STATUS Status;
|
|
PNDIS_CONFIGURATION_PARAMETER Parameter;
|
|
|
|
UINT BusNumber = 0;
|
|
|
|
NDIS_STRING Keyword = LT_REG_KEY_BUS_NUMBER_STRING;
|
|
|
|
NdisReadConfiguration(
|
|
&Status,
|
|
&Parameter,
|
|
ConfigHandle,
|
|
&Keyword,
|
|
NdisParameterInteger);
|
|
|
|
if (Status == NDIS_STATUS_SUCCESS)
|
|
{
|
|
BusNumber = (UINT)Parameter->ParameterData.IntegerData;
|
|
}
|
|
|
|
return(BusNumber);
|
|
}
|
|
|
|
|
|
NDIS_STATUS
|
|
LtRegGetBusType(
|
|
IN NDIS_HANDLE ConfigHandle,
|
|
OUT PNDIS_INTERFACE_TYPE BusType
|
|
)
|
|
/*++
|
|
|
|
Routine Description:
|
|
|
|
This routine determines the type of bus the card is installed on
|
|
|
|
Arguments:
|
|
|
|
ConfigHandle : The handle to the configuration database
|
|
BusType : On return, the bus type is stored here
|
|
|
|
Return Value:
|
|
|
|
NDIS_STATUS_SUCCESS : if successfully read from the config database
|
|
NDIS_STATUS_FAILURE : if unable to find the information in the config
|
|
database
|
|
|
|
--*/
|
|
{
|
|
NDIS_STATUS Status;
|
|
PNDIS_CONFIGURATION_PARAMETER Parameter;
|
|
|
|
NDIS_STRING Keyword = LT_REG_KEY_BUS_TYPE_STRING;
|
|
|
|
NdisReadConfiguration(
|
|
&Status,
|
|
&Parameter,
|
|
ConfigHandle,
|
|
&Keyword,
|
|
NdisParameterInteger);
|
|
|
|
if (Status == NDIS_STATUS_SUCCESS)
|
|
{
|
|
*BusType = (UINT)Parameter->ParameterData.IntegerData;
|
|
}
|
|
|
|
return(Status);
|
|
}
|
|
|
|
|
|
UCHAR
|
|
LtRegGetNodeId(
|
|
IN NDIS_HANDLE ConfigHandle
|
|
)
|
|
/*++
|
|
|
|
Routine Description:
|
|
|
|
This routine determines the last NodeId used by the card.
|
|
|
|
Arguments:
|
|
|
|
ConfigHandle : The handle to the configuration database
|
|
|
|
Return Value:
|
|
|
|
Returns the last valid NodeId used by the card. If we find that
|
|
the value stored in the configuration info is not valid, then the
|
|
suggested NodeId is returned.
|
|
|
|
--*/
|
|
{
|
|
NDIS_STATUS Status;
|
|
PNDIS_CONFIGURATION_PARAMETER Parameter;
|
|
|
|
NDIS_STRING Keyword = LT_REG_KEY_NODE_ID_STRING;
|
|
UCHAR NodeId = 0;
|
|
|
|
NdisReadConfiguration(
|
|
&Status,
|
|
&Parameter,
|
|
ConfigHandle,
|
|
&Keyword,
|
|
NdisParameterInteger);
|
|
|
|
if (Status == NDIS_STATUS_SUCCESS)
|
|
{
|
|
NodeId = (UCHAR)Parameter->ParameterData.IntegerData;
|
|
if ((NodeId < LT_NODE_ID_MIN) || (NodeId > LT_NODE_ID_MAX))
|
|
{
|
|
|
|
NodeId = 0;
|
|
}
|
|
}
|
|
|
|
return(NodeId);
|
|
}
|
|
|
|
|
|
NDIS_STATUS
|
|
LtRegGetIoBaseAddr(
|
|
OUT PUINT IoBaseAddress,
|
|
IN NDIS_HANDLE NdisConfigHandle,
|
|
IN NDIS_HANDLE ConfigHandle,
|
|
IN NDIS_INTERFACE_TYPE BusType
|
|
)
|
|
/*++
|
|
|
|
Routine Description:
|
|
|
|
This routine determines the port addresses used to communicate
|
|
with the card.
|
|
|
|
Arguments:
|
|
|
|
IoBaseAddress : On return, the I/O port address is stored here
|
|
ConfigHandle : The handle to the configuration database
|
|
SlotNumber : For MCA machines, the indicates the slot the card is in
|
|
BusType : The type of bus the card is located on
|
|
|
|
Return Value:
|
|
|
|
NDIS_STATUS_SUCCESS : if successful
|
|
NDIS_STATUS_ADAPTER_NOT_FOUND : if running on a MCA machine and
|
|
the adapter cannot be located
|
|
NDIS_STATUS_BAD_CHARACTERISTICS : if the I/O base is not within
|
|
the legal range
|
|
|
|
--*/
|
|
{
|
|
NDIS_MCA_POS_DATA McaData;
|
|
NDIS_STATUS Status;
|
|
PNDIS_CONFIGURATION_PARAMETER Parameter;
|
|
|
|
NDIS_STRING Keyword = LT_REG_KEY_IO_BASE_ADDRESS_STRING;
|
|
UINT SlotNumber = 0;
|
|
|
|
// If BusType is NdisInterfaceMca, then we read the MCA POS info to
|
|
// get our parameters. Otherwise, we just read the registry.
|
|
|
|
if (BusType == NdisInterfaceMca)
|
|
{
|
|
NdisReadMcaPosInformation(
|
|
&Status,
|
|
NdisConfigHandle,
|
|
&SlotNumber,
|
|
&McaData);
|
|
|
|
// *IoBaseAddress = (UINT)(McaData.PosData2 | (McaData.PosData3 << 8));
|
|
*IoBaseAddress = LT_DECODE_ADDR_FROM_POSDATA(McaData);
|
|
|
|
DBGPRINT(DBG_COMP_REGISTRY, DBG_LEVEL_FATAL,
|
|
("LtRegGetIoBaseAddr: Base %lx. %lx.%lx.%lx.%lx, Id - %lx\n",
|
|
*IoBaseAddress, McaData.PosData1, McaData.PosData2,
|
|
McaData.PosData3, McaData.PosData4, McaData.AdapterId));
|
|
|
|
if ((Status != NDIS_STATUS_SUCCESS) || (McaData.AdapterId != LT_MCA_POS_ID))
|
|
{
|
|
Status = NDIS_STATUS_ADAPTER_NOT_FOUND;
|
|
}
|
|
|
|
}
|
|
else
|
|
{
|
|
NdisReadConfiguration(
|
|
&Status,
|
|
&Parameter,
|
|
ConfigHandle,
|
|
&Keyword,
|
|
NdisParameterHexInteger);
|
|
|
|
if (Status == NDIS_STATUS_SUCCESS)
|
|
{
|
|
*IoBaseAddress = (UINT)Parameter->ParameterData.IntegerData;
|
|
}
|
|
}
|
|
|
|
if ((Status == NDIS_STATUS_SUCCESS) &&
|
|
((*IoBaseAddress < LT_IO_BASE_ADDRESS_MIN) ||
|
|
(*IoBaseAddress > LT_IO_BASE_ADDRESS_MAX)))
|
|
{
|
|
DBGPRINT(DBG_COMP_REGISTRY, DBG_LEVEL_FATAL,
|
|
("LtRegGetIoBaseAddr: invalid value found for %s\n", LT_REG_KEY_IO_BASE_ADDRESS));
|
|
|
|
Status = NDIS_STATUS_BAD_CHARACTERISTICS;
|
|
}
|
|
|
|
return(Status);
|
|
}
|
|
|
|
|