Copyright (c) 1992 Microsoft Corporation
|
|
|
|
Module Name:
|
|
|
|
ne3200sw.h
|
|
|
|
Abstract:
|
|
|
|
Software specific values for the Novell NE3200 NDIS 3.0 driver.
|
|
|
|
Author:
|
|
|
|
Keith Moore (KeithMo) 08-Jan-1991
|
|
|
|
Environment:
|
|
|
|
Architecturally, there is an assumption in this driver that we are
|
|
on a little endian machine.
|
|
|
|
Notes:
|
|
|
|
optional-notes
|
|
|
|
Revision History:
|
|
|
|
|
|
--*/
|
|
|
|
#ifndef _NE3200SOFTWARE_
|
|
#define _NE3200SOFTWARE_
|
|
|
|
#include <ndis.h>
|
|
#include <ne3200hw.h>
|
|
|
|
//
|
|
// Debugging flags. This buffer is used to record whenever the driver
|
|
// does something important. If there is a bug, then this buffer
|
|
// can be viewed from the debugger and an effective trace of events
|
|
// can be found.
|
|
//
|
|
|
|
#if DBG
|
|
|
|
#define IF_NE3200DBG(flag) if (NE3200Debug & (NE3200_DEBUG_ ## flag))
|
|
|
|
//
|
|
// Macro for putting a character in the buffer.
|
|
//
|
|
#define IF_LOG(ch) { \
|
|
UCHAR lp = Adapter->LogPlace; \
|
|
Adapter->LogPlace++; \
|
|
Adapter->Log[(UCHAR)(lp+3)] = (UCHAR)'\0'; \
|
|
Adapter->Log[lp] = (ch); \
|
|
}
|
|
|
|
//
|
|
// Debug flag, determines what debug information is kept around
|
|
//
|
|
extern ULONG NE3200Debug;
|
|
|
|
//
|
|
// Possible values for the above flag
|
|
//
|
|
#define NE3200_DEBUG_DUMP_LOOKAHEAD 0x00000001 // dump lookahead buffer
|
|
#define NE3200_DEBUG_DUMP_TRANSFER 0x00000002 // dump transfer buffer
|
|
#define NE3200_DEBUG_DUMP_SEND 0x00000004 // dump send packet
|
|
#define NE3200_DEBUG_DUMP_COMMAND 0x00000008 // dump command block & buffer
|
|
|
|
#define NE3200_DEBUG_ACQUIRE 0x00000010 // NE3200AcquireCommandBlock activity
|
|
#define NE3200_DEBUG_SUBMIT 0x00000020 // NE3200SubmitCommandBlock activity
|
|
#define NE3200_DEBUG_ASSIGN 0x00000040 // NE3200AssignPacketToCommandBlock activity
|
|
#define NE3200_DEBUG_RECEIVE 0x00000080 // ProcessReceiveInterrupts activity
|
|
|
|
#define NE3200_DEBUG_LOUD 0x00000100 // print things
|
|
#define NE3200_DEBUG_VERY_LOUD 0x00000200 // print lots of things
|
|
|
|
#define DPrint1(fmt) DbgPrint(fmt)
|
|
#define DPrint2(fmt,v1) DbgPrint(fmt,v1)
|
|
#define DPrint3(fmt,v1,v2) DbgPrint(fmt,v1,v2)
|
|
#define DPrint4(fmt,v1,v2,v3) DbgPrint(fmt,v1,v2,v3)
|
|
|
|
#else // DBG
|
|
|
|
#define IF_LOG(ch)
|
|
|
|
#define IF_NE3200DBG(flag) if (0)
|
|
#define DPrint1(fmt)
|
|
#define DPrint2(fmt,v1)
|
|
#define DPrint3(fmt,v1,v2)
|
|
#define DPrint4(fmt,v1,v2,v3)
|
|
|
|
#endif // DBG
|
|
|
|
//
|
|
// Keep symbols for internal functions
|
|
//
|
|
#define STATIC
|
|
|
|
//
|
|
// NDIS version of this driver
|
|
//
|
|
#define NE3200_NDIS_MAJOR_VERSION 3
|
|
#define NE3200_NDIS_MINOR_VERSION 0
|
|
|
|
|
|
extern NDIS_PHYSICAL_ADDRESS MinusOne;
|
|
|
|
//
|
|
// Macro for allocating memory
|
|
//
|
|
#define NE3200_ALLOC_PHYS(_Status, _pBuffer, _Length) \
|
|
{ \
|
|
*(_Status) = NdisAllocateMemory( \
|
|
(PVOID*)(_pBuffer), \
|
|
(_Length), \
|
|
0, \
|
|
MinusOne); \
|
|
}
|
|
|
|
//
|
|
// Macro for freeing memory
|
|
//
|
|
#define NE3200_FREE_PHYS(_Buffer) NdisFreeMemory((_Buffer), 0, 0)
|
|
|
|
|
|
//
|
|
// Macro for moving memory around
|
|
//
|
|
#define NE3200_MOVE_MEMORY(Destination,Source,Length) NdisMoveMemory(Destination,Source,Length)
|
|
|
|
//
|
|
// Size of ethernet header
|
|
//
|
|
#define NE3200_HEADER_SIZE 14
|
|
|
|
//
|
|
// Size of lookahead buffer for loopback packets
|
|
//
|
|
#define NE3200_SIZE_OF_LOOPBACK 256
|
|
|
|
|
|
//
|
|
// The implementation of RESET.
|
|
//
|
|
// The NE3200 must be "held by the hand" during the reset & download
|
|
// operations. Typically, the reset (or download) is initiated and
|
|
// the status ports are POLLED, waiting for pass/fail status. This
|
|
// is unacceptable in NT.
|
|
//
|
|
// To handle this cleanly in NT, the reset & download operations will
|
|
// be controlled by a state machine. This state machine will be
|
|
// contained by a flag and driven by a Timer Object.
|
|
//
|
|
// This ENUM represents the current state of the reset operation.
|
|
//
|
|
typedef enum _NE3200_RESET_STATE {
|
|
|
|
NE3200ResetStateStarting,
|
|
NE3200ResetStateResetting,
|
|
NE3200ResetStateDownloading,
|
|
NE3200ResetStateReloadAddress,
|
|
NE3200ResetStateComplete
|
|
|
|
} NE3200_RESET_STATE, *PNE3200_RESET_STATE;
|
|
|
|
//
|
|
// This ENUM represents the result of the reset operation.
|
|
//
|
|
typedef enum _NE3200_RESET_RESULT {
|
|
|
|
NE3200ResetResultSuccessful,
|
|
NE3200ResetResultResetFailure,
|
|
NE3200ResetResultResetTimeout,
|
|
NE3200ResetResultInitializationFailure,
|
|
NE3200ResetResultInitializationTimeout,
|
|
NE3200ResetResultInvalidState,
|
|
NE3200ResetResultResources
|
|
|
|
} NE3200_RESET_RESULT, *PNE3200_RESET_RESULT;
|
|
|
|
|
|
struct _NE3200_ADAPTER;
|
|
|
|
//
|
|
// This structure defines the global data needed by the driver.
|
|
//
|
|
typedef struct _NE3200_GLOBAL_DATA {
|
|
|
|
//
|
|
// We need to allocate a buffer to contain the MAC.BIN code to be
|
|
// downloaded to the NE3200 adapter(s). This field will contain
|
|
// the virtual address of this buffer.
|
|
//
|
|
PVOID MacBinVirtualAddress;
|
|
NDIS_PHYSICAL_ADDRESS MacBinPhysicalAddress;
|
|
|
|
//
|
|
// Chain of Adapters
|
|
//
|
|
LIST_ENTRY AdapterList;
|
|
|
|
//
|
|
// The handle of the adapter used for the allocaton of
|
|
// the MAC.BIN buffer (the first one added for this MAC).
|
|
//
|
|
NDIS_HANDLE MacBinAdapterHandle;
|
|
|
|
//
|
|
// Handle to our driver
|
|
//
|
|
NDIS_HANDLE NE3200DriverHandle;
|
|
|
|
//
|
|
// Handle for NdisTerminateWrapper
|
|
//
|
|
NDIS_HANDLE NE3200NdisWrapperHandle;
|
|
|
|
//
|
|
// This field contains the actual length (in bytes) of MAC.BIN.
|
|
//
|
|
USHORT MacBinLength;
|
|
|
|
} NE3200_GLOBAL_DATA, *PNE3200_GLOBAL_DATA;
|
|
|
|
//
|
|
// In addition to the Command Block fields which the NE3200
|
|
// defines, we need some additional fields for our own purposes.
|
|
// To ensure that these fields are properly aligned (and to
|
|
// ensure that the actual Command Block is properly aligned)
|
|
// we'll defined a Super Command Block. This structure will
|
|
// contain a "normal" NE3200 Command Block plus some additional
|
|
// fields.
|
|
//
|
|
typedef struct _NE3200_SUPER_COMMAND_BLOCK {
|
|
|
|
//
|
|
// The actual NE3200 Command Block.
|
|
//
|
|
NE3200_COMMAND_BLOCK Hardware;
|
|
|
|
//
|
|
// This contains the physical address of the above Command Block.
|
|
//
|
|
NDIS_PHYSICAL_ADDRESS Self;
|
|
|
|
//
|
|
// Points to the packet from which data is being transmitted
|
|
// through this Command Block.
|
|
//
|
|
PNDIS_PACKET OwningPacket;
|
|
|
|
//
|
|
// This tells if the command block is a public or private command block.
|
|
//
|
|
PUINT AvailableCommandBlockCounter;
|
|
|
|
//
|
|
// This contains the virtual address of the next pending command.
|
|
//
|
|
struct _NE3200_SUPER_COMMAND_BLOCK *NextCommand;
|
|
|
|
//
|
|
// Is this from a set
|
|
//
|
|
BOOLEAN Set;
|
|
|
|
//
|
|
// This field is used to timestamp the command blocks
|
|
// as they are placed into the command queue. If a
|
|
// block fails to execute, the adapter will get a kick in the ass to
|
|
// start it up again.
|
|
//
|
|
BOOLEAN Timeout;
|
|
|
|
//
|
|
// If this is a public (adapter-wide) command block, then
|
|
// this will contain this block's index into the adapter's
|
|
// command queue.
|
|
//
|
|
USHORT CommandBlockIndex;
|
|
|
|
//
|
|
// Count of the number of times we have retried a command.
|
|
//
|
|
UCHAR TimeoutCount;
|
|
|
|
//
|
|
// When a packet is submitted to the hardware we record
|
|
// here whether it used adapter buffers and if so, the buffer
|
|
// index.
|
|
//
|
|
BOOLEAN UsedNE3200Buffer;
|
|
UINT NE3200BuffersIndex;
|
|
|
|
} NE3200_SUPER_COMMAND_BLOCK, *PNE3200_SUPER_COMMAND_BLOCK;
|
|
|
|
//
|
|
// In addition to the Receive Entry fields which the NE3200
|
|
// defines, we need some additional fields for our own purposes.
|
|
// To ensure that these fields are properly aligned (and to
|
|
// ensure that the actual Receive Entry is properly aligned)
|
|
// we'll defined a Super Receive Entry. This structure will
|
|
// contain a "normal" NE3200 Receive Entry plus some additional
|
|
// fields.
|
|
//
|
|
typedef struct _NE3200_SUPER_RECEIVE_ENTRY {
|
|
|
|
//
|
|
// The actual NE3200 Receive Entry.
|
|
//
|
|
NE3200_RECEIVE_ENTRY Hardware;
|
|
|
|
//
|
|
// This contains the physical address of the above Receive Entry.
|
|
//
|
|
NDIS_PHYSICAL_ADDRESS Self;
|
|
|
|
//
|
|
// This contains the virtual address of the next
|
|
// Receive Entry in the Receive Queue.
|
|
//
|
|
struct _NE3200_SUPER_RECEIVE_ENTRY *NextEntry;
|
|
|
|
//
|
|
// This contains the virtual address of this Receive Entry's
|
|
// frame buffer.
|
|
//
|
|
PVOID ReceiveBuffer;
|
|
NDIS_PHYSICAL_ADDRESS ReceiveBufferPhysical;
|
|
|
|
//
|
|
// Points to an NDIS buffer which describes this buffer
|
|
//
|
|
PNDIS_BUFFER FlushBuffer;
|
|
|
|
} NE3200_SUPER_RECEIVE_ENTRY, *PNE3200_SUPER_RECEIVE_ENTRY;
|
|
|
|
|
|
|
|
//
|
|
// This record type is inserted into the MiniportReserved portion
|
|
// of the packet header when the packet is going through the
|
|
// staged allocation of buffer space prior to the actual send.
|
|
//
|
|
typedef struct _NE3200_RESERVED {
|
|
|
|
//
|
|
// Points to the next packet in the chain of queued packets
|
|
// being allocated or waiting for the finish of transmission.
|
|
//
|
|
PNDIS_PACKET Next;
|
|
|
|
//
|
|
// If TRUE then the packet caused an adapter buffer to
|
|
// be allocated.
|
|
//
|
|
BOOLEAN UsedNE3200Buffer;
|
|
|
|
//
|
|
// If the previous field was TRUE then this gives the
|
|
// index into the array of adapter buffer descriptors that
|
|
// contains the old packet information.
|
|
//
|
|
UCHAR NE3200BuffersIndex;
|
|
|
|
//
|
|
// Gives the index of the Command Block as well as the
|
|
// command block to packet structure.
|
|
//
|
|
USHORT CommandBlockIndex;
|
|
|
|
} NE3200_RESERVED,*PNE3200_RESERVED;
|
|
|
|
//
|
|
// This macro will return a pointer to the NE3200 reserved portion
|
|
// of a packet given a pointer to a packet.
|
|
//
|
|
#define PNE3200_RESERVED_FROM_PACKET(Packet) \
|
|
((PNE3200_RESERVED)((Packet)->MiniportReserved))
|
|
|
|
//
|
|
// If an ndis packet does not meet the hardware contraints then
|
|
// an adapter buffer will be allocated. Enough data will be copied
|
|
// out of the ndis packet so that by using a combination of the
|
|
// adapter buffer and remaining ndis buffers the hardware
|
|
// constraints are satisfied.
|
|
//
|
|
// In the NE3200_ADAPTER structure three threaded lists are kept in
|
|
// one array. One points to a list of NE3200_BUFFER_DESCRIPTORS
|
|
// that point to small adapter buffers. Another is for medium sized
|
|
// buffers and the last for full sized (large) buffers.
|
|
//
|
|
// The allocation is controlled via a free list head and
|
|
// the free lists are "threaded" by a field in the adapter buffer
|
|
// descriptor.
|
|
//
|
|
typedef struct _NE3200_BUFFER_DESCRIPTOR {
|
|
|
|
//
|
|
// A physical pointer to a small, medium, or large buffer.
|
|
//
|
|
NDIS_PHYSICAL_ADDRESS PhysicalNE3200Buffer;
|
|
|
|
//
|
|
// A virtual pointer to a small, medium, or large buffer.
|
|
//
|
|
PVOID VirtualNE3200Buffer;
|
|
|
|
//
|
|
// Flush buffer
|
|
//
|
|
PNDIS_BUFFER FlushBuffer;
|
|
|
|
//
|
|
// Threads the elements of an array of these descriptors into
|
|
// a free list. -1 implies no more entries in the list.
|
|
//
|
|
INT Next;
|
|
|
|
//
|
|
// Holds the amount of space (in bytes) available in the buffer
|
|
//
|
|
UINT BufferSize;
|
|
|
|
//
|
|
// Holds the length of data placed into the buffer. This
|
|
// can (and likely will) be less that the actual buffers
|
|
// length.
|
|
//
|
|
UINT DataLength;
|
|
|
|
} NE3200_BUFFER_DESCRIPTOR,*PNE3200_BUFFER_DESCRIPTOR;
|
|
|
|
//
|
|
// This is the main structure for each adapter.
|
|
//
|
|
typedef struct _NE3200_ADAPTER {
|
|
|
|
#if DBG
|
|
PUCHAR LogAddress;
|
|
#endif
|
|
|
|
PUCHAR SystemDoorbellInterruptPort;
|
|
PUCHAR SystemDoorbellMaskPort;
|
|
|
|
//
|
|
// Flag that when enabled lets routines know that a reset
|
|
// is in progress.
|
|
//
|
|
BOOLEAN ResetInProgress;
|
|
|
|
//
|
|
// TRUE when a receive interrupt is received
|
|
//
|
|
BOOLEAN ReceiveInterrupt;
|
|
|
|
BOOLEAN InterruptsDisabled;
|
|
|
|
//
|
|
// Handle given by NDIS when the widget was initialized.
|
|
//
|
|
NDIS_HANDLE MiniportAdapterHandle;
|
|
|
|
//
|
|
// Pointer to the head of the Receive Queue.
|
|
//
|
|
PNE3200_SUPER_RECEIVE_ENTRY ReceiveQueueHead;
|
|
|
|
//
|
|
// Pointer to the tail of the Receive Queue.
|
|
//
|
|
PNE3200_SUPER_RECEIVE_ENTRY ReceiveQueueTail;
|
|
|
|
//
|
|
// Packet counts
|
|
//
|
|
UINT GoodReceives;
|
|
|
|
//
|
|
// Pointer to the next command to complete execution.
|
|
//
|
|
PNE3200_SUPER_COMMAND_BLOCK FirstCommandOnCard;
|
|
|
|
//
|
|
// Pointers to an array of adapter buffer descriptors.
|
|
// The array will actually be threaded together by
|
|
// three free lists. The lists will be for small,
|
|
// medium and full sized packets.
|
|
//
|
|
PNE3200_BUFFER_DESCRIPTOR NE3200Buffers;
|
|
|
|
//
|
|
// List head for the adapters buffers. If the list
|
|
// head is equal to -1 then there are no free elements
|
|
// on the list.
|
|
//
|
|
INT NE3200BufferListHead;
|
|
|
|
UINT GoodTransmits;
|
|
|
|
//
|
|
// Is there an outstanding request
|
|
//
|
|
BOOLEAN RequestInProgress;
|
|
|
|
//
|
|
// Is this a packet resubmission?
|
|
//
|
|
BOOLEAN PacketResubmission;
|
|
|
|
//
|
|
// Pointer to the most recently submitted command.
|
|
//
|
|
PNE3200_SUPER_COMMAND_BLOCK LastCommandOnCard;
|
|
|
|
//
|
|
// Pointer to the first command waiting to be put on the list to the card.
|
|
//
|
|
PNE3200_SUPER_COMMAND_BLOCK FirstWaitingCommand;
|
|
|
|
//
|
|
// Pointer to the last command waiting to be put on the list to the card.
|
|
//
|
|
PNE3200_SUPER_COMMAND_BLOCK LastWaitingCommand;
|
|
|
|
PUCHAR BaseMailboxPort;
|
|
|
|
//
|
|
// Total number of Command Blocks in the PublicCommandQueue.
|
|
//
|
|
UINT NumberOfPublicCommandBlocks;
|
|
|
|
//
|
|
// Number of available Command Blocks in the Command Queue.
|
|
//
|
|
UINT NumberOfAvailableCommandBlocks;
|
|
|
|
//
|
|
// Pointer to the next available Command Block.
|
|
//
|
|
PNE3200_SUPER_COMMAND_BLOCK NextCommandBlock;
|
|
|
|
PNE3200_SUPER_COMMAND_BLOCK LastCommandBlockAllocated;
|
|
//----
|
|
//
|
|
// Used for filter and statistics operations
|
|
//
|
|
PNE3200_SUPER_COMMAND_BLOCK PublicCommandQueue;
|
|
NDIS_PHYSICAL_ADDRESS PublicCommandQueuePhysical;
|
|
|
|
//
|
|
// Used for padding short packets
|
|
//
|
|
PUCHAR PaddingVirtualAddress;
|
|
NDIS_PHYSICAL_ADDRESS PaddingPhysicalAddress;
|
|
|
|
//
|
|
// Points to the card multicast entry table
|
|
//
|
|
PUCHAR CardMulticastTable;
|
|
NDIS_PHYSICAL_ADDRESS CardMulticastTablePhysical;
|
|
|
|
//
|
|
// Holds the interrupt object for this adapter.
|
|
//
|
|
NDIS_MINIPORT_INTERRUPT Interrupt;
|
|
|
|
//
|
|
// Current packet filter on adapter
|
|
//
|
|
UINT CurrentPacketFilter;
|
|
|
|
//
|
|
// Is this the initial initialization reset?
|
|
//
|
|
BOOLEAN InitialInit;
|
|
|
|
//
|
|
// These variables hold information about a pending request.
|
|
//
|
|
PUINT BytesWritten;
|
|
PUINT BytesNeeded;
|
|
NDIS_OID Oid;
|
|
PVOID InformationBuffer;
|
|
UINT InformationBufferLength;
|
|
|
|
//
|
|
// The EISA Slot Number for this adapter.
|
|
//
|
|
USHORT EisaSlot;
|
|
|
|
//
|
|
// The I/O Base address of the adapter.
|
|
//
|
|
ULONG AdapterIoBase;
|
|
|
|
//
|
|
// Various mapped I/O Port Addresses for this adapter.
|
|
//
|
|
PUCHAR ResetPort;
|
|
PUCHAR SystemInterruptPort;
|
|
PUCHAR LocalDoorbellInterruptPort;
|
|
|
|
//
|
|
// Count of CheckForHang calls that have occurred without
|
|
// a receive interrupt.
|
|
//
|
|
UCHAR NoReceiveInterruptCount;
|
|
|
|
//
|
|
// TRUE when a send interrupt is received
|
|
//
|
|
BOOLEAN SendInterrupt;
|
|
|
|
//
|
|
// Should we use an alternative address
|
|
//
|
|
BOOLEAN AddressChanged;
|
|
|
|
//
|
|
// The network address from the hardware.
|
|
//
|
|
CHAR NetworkAddress[NE3200_LENGTH_OF_ADDRESS];
|
|
CHAR CurrentAddress[NE3200_LENGTH_OF_ADDRESS];
|
|
|
|
//
|
|
// Pointer to the Receive Queue.
|
|
//
|
|
PNE3200_SUPER_RECEIVE_ENTRY ReceiveQueue;
|
|
NDIS_PHYSICAL_ADDRESS ReceiveQueuePhysical;
|
|
|
|
//
|
|
// Pointer to the Command Queue.
|
|
//
|
|
PNE3200_SUPER_COMMAND_BLOCK CommandQueue;
|
|
NDIS_PHYSICAL_ADDRESS CommandQueuePhysical;
|
|
|
|
//
|
|
// Next free public command block
|
|
//
|
|
UINT NextPublicCommandBlock;
|
|
|
|
//
|
|
// Total number of Command Blocks in the Command Queue.
|
|
//
|
|
UINT NumberOfCommandBlocks;
|
|
|
|
//
|
|
// Total number of Receive Buffers.
|
|
//
|
|
UINT NumberOfReceiveBuffers;
|
|
|
|
//
|
|
// Total number of Transmit Buffers.
|
|
//
|
|
UINT NumberOfTransmitBuffers;
|
|
|
|
//
|
|
// The Flush buffer pool
|
|
//
|
|
PNDIS_HANDLE FlushBufferPoolHandle;
|
|
|
|
//
|
|
// Is the reset to be done asynchronously?
|
|
//
|
|
BOOLEAN ResetAsynchronous;
|
|
|
|
//
|
|
// Used to store the command block for asynchronous resetting.
|
|
//
|
|
PNE3200_SUPER_COMMAND_BLOCK ResetHandlerCommandBlock;
|
|
|
|
//
|
|
// Index of the receive ring descriptor that started the
|
|
// last packet not completely received by the hardware.
|
|
//
|
|
UINT CurrentReceiveIndex;
|
|
|
|
//
|
|
// Counters to hold the various number of errors/statistics for both
|
|
// reception and transmission.
|
|
//
|
|
|
|
//
|
|
// Packet counts
|
|
//
|
|
UINT TransmitsQueued;
|
|
|
|
//
|
|
// Count of transmit errors
|
|
//
|
|
UINT RetryFailure;
|
|
UINT LostCarrier;
|
|
UINT UnderFlow;
|
|
UINT NoClearToSend;
|
|
UINT Deferred;
|
|
UINT OneRetry;
|
|
UINT MoreThanOneRetry;
|
|
|
|
//
|
|
// Count of receive errors
|
|
//
|
|
UINT CrcErrors;
|
|
UINT AlignmentErrors;
|
|
UINT OutOfResources;
|
|
UINT DmaOverruns;
|
|
|
|
//
|
|
// This holds the current state of the reset operation.
|
|
//
|
|
NE3200_RESET_STATE ResetState;
|
|
|
|
//
|
|
// This hold the result of the reset operation.
|
|
//
|
|
NE3200_RESET_RESULT ResetResult;
|
|
|
|
//
|
|
// This is a timeout counter. Before a timed operation is
|
|
// started, a positive value is placed in this field. Every
|
|
// time the particular state is entered in the ResetDpc, this
|
|
// value is decremented. If this value becomes zero, then
|
|
// the operation has timed-out and the adapter is toast.
|
|
//
|
|
UINT ResetTimeoutCounter;
|
|
|
|
//
|
|
// This timer object will be used to queue the deferred processing routine
|
|
//
|
|
NDIS_MINIPORT_TIMER DeferredTimer;
|
|
|
|
//
|
|
// This timer is for handling resets from when the card is dead.
|
|
//
|
|
NDIS_MINIPORT_TIMER ResetTimer;
|
|
|
|
//
|
|
// Place for holding command block for pending commands during
|
|
// reset processing.
|
|
//
|
|
PNE3200_SUPER_COMMAND_BLOCK ResetCommandBlock;
|
|
|
|
//
|
|
// This is a pointer to the Configuration Block for this
|
|
// adapter. The Configuration Block will be modified during
|
|
// changes to the packet filter.
|
|
//
|
|
PNE3200_CONFIGURATION_BLOCK ConfigurationBlock;
|
|
NDIS_PHYSICAL_ADDRESS ConfigurationBlockPhysical;
|
|
|
|
//
|
|
// This points to the next adapter registered for the same Mac
|
|
//
|
|
LIST_ENTRY AdapterList;
|
|
|
|
#if DBG
|
|
UCHAR Log[256];
|
|
UCHAR LogPlace;
|
|
#endif
|
|
|
|
} NE3200_ADAPTER,*PNE3200_ADAPTER;
|
|
|
|
//
|
|
// Given a MiniportContextHandle return the PNE3200_ADAPTER
|
|
// it represents.
|
|
//
|
|
#define PNE3200_ADAPTER_FROM_CONTEXT_HANDLE(Handle) \
|
|
((PNE3200_ADAPTER)(Handle))
|
|
|
|
//
|
|
// Procedures which do error logging
|
|
//
|
|
|
|
typedef enum _NE3200_PROC_ID{
|
|
allocateAdapterMemory,
|
|
initialInit,
|
|
setConfigurationBlockAndInit,
|
|
registerAdapter,
|
|
openAdapter,
|
|
wakeUpDpc,
|
|
resetDpc
|
|
}NE3200_PROC_ID;
|
|
|
|
//
|
|
// Error log codes.
|
|
//
|
|
#define NE3200_ERRMSG_ALLOC_MEM (ULONG)0x01
|
|
#define NE3200_ERRMSG_INIT_INTERRUPT (ULONG)0x02
|
|
#define NE3200_ERRMSG_NO_DELAY (ULONG)0x03
|
|
#define NE3200_ERRMSG_INIT_DB (ULONG)0x04
|
|
#define NE3200_ERRMSG_OPEN_DB (ULONG)0x05
|
|
#define NE3200_ERRMSG_BAD_STATE (ULONG)0x06
|
|
#define NE3200_ERRMSG_ (ULONG)0x06
|
|
|
|
|
|
//
|
|
// Define our block of global data. The actual data resides in NE3200.C.
|
|
//
|
|
extern NE3200_GLOBAL_DATA NE3200Globals;
|
|
|
|
#include <ne3200pr.h>
|
|
|
|
#endif // _NE3200SOFTWARE_
|