// Microsoft Windows
// Copyright (C) Microsoft Corporation 1996-2001.
//
// File: wrapper.cpp
//
//----------------------------------------------------------------------------
#include "stdafx.h"
#include "util.h"
#include "resource.h"
#include "winreg.h"
#include "areaprog.h"
#include "wrapper.h"
#include "dsgetdc.h"
typedef DWORD (WINAPI *PFNDSGETDCNAME)(LPCWSTR, LPCWSTR, GUID *, LPCWSTR, ULONG, PDOMAIN_CONTROLLER_INFOW *);
typedef struct { LPCWSTR szProfile; LPCWSTR szDatabase; LPCWSTR szLog; AREA_INFORMATION Area; LPVOID *pHandle; PSCE_AREA_CALLBACK_ROUTINE pCallback; HANDLE hWndCallback; DWORD dwFlags; } ENGINEARGS;
BOOL PostProgressArea( IN HANDLE CallbackHandle, IN AREA_INFORMATION Area, IN DWORD TotalTicks, IN DWORD CurrentTicks );
static BOOL bRangeSet=FALSE;
CRITICAL_SECTION csOpenDatabase; #define OPEN_DATABASE_TIMEOUT INFINITE
//
// Helper functions to call the engine from a secondary thread:
//
DWORD WINAPI InspectSystemEx(LPVOID lpv) {
if ( lpv == NULL ) return ERROR_INVALID_PARAMETER;
ENGINEARGS *ea; SCESTATUS rc; ea = (ENGINEARGS *)lpv;
DWORD dWarning=0; rc = SceAnalyzeSystem(NULL, ea->szProfile, ea->szDatabase, ea->szLog, SCE_UPDATE_DB|SCE_VERBOSE_LOG, ea->Area, ea->pCallback, ea->hWndCallback, &dWarning // this is required (by RPC)
); return rc; }
//
// call to SCE engine to apply the template
//
DWORD WINAPI ApplyTemplateEx(LPVOID lpv) {
if ( lpv == NULL ) return ERROR_INVALID_PARAMETER;
ENGINEARGS *ea; SCESTATUS rc; ea = (ENGINEARGS *)lpv;
rc = SceConfigureSystem(NULL, ea->szProfile, ea->szDatabase, ea->szLog, SCE_OVERWRITE_DB|SCE_VERBOSE_LOG, ea->Area, ea->pCallback, ea->hWndCallback, NULL );
return rc; }
WINBASEAPI BOOL WINAPI TryEnterCriticalSection( LPCRITICAL_SECTION lpCriticalSection );
/*------------------------------------------------------------------------------
Method: OpenDatabaseEx
Synopsis: open database on a separate thread
Arugments:
Returns:
History: a-mthoge 06-09-1998 - Added the _NT4BACK_PORT compile condition. ------------------------------------------------------------------------------*/ DWORD WINAPI OpenDatabaseEx(LPVOID lpv) {
if ( lpv == NULL ) return ERROR_INVALID_PARAMETER;
ENGINEARGS *ea; SCESTATUS rc=0;
if (TryEnterCriticalSection(&csOpenDatabase)) { ea = (ENGINEARGS *)lpv;
rc = SceOpenProfile(ea->szProfile, (SCE_FORMAT_TYPE) ea->dwFlags, // SCE_JET_FORMAT || SCE_JET_ANALYSIS_REQUIRED
ea->pHandle );
LeaveCriticalSection(&csOpenDatabase); } else { rc = SCESTATUS_OTHER_ERROR; } return rc; }
//
// Assign a template to the system without configuring it
//
SCESTATUS AssignTemplate(LPCWSTR szTemplate, LPCWSTR szDatabase, BOOL bIncremental) { SCESTATUS rc;
rc = SceConfigureSystem(NULL, szTemplate, szDatabase, NULL, (bIncremental ? SCE_UPDATE_DB : SCE_OVERWRITE_DB) | SCE_NO_CONFIG | SCE_VERBOSE_LOG, AREA_ALL, NULL, NULL, NULL );
return rc; }
//
// apply a template to the system
//
DWORD ApplyTemplate( LPCWSTR szProfile, LPCWSTR szDatabase, LPCWSTR szLogFile, AREA_INFORMATION Area ) { // Spawn a thread to call the engine & apply the profile, since this can
// take a while and we want to stay responsive & have a change to provide
// feedback.
ENGINEARGS ea; HANDLE hThread=NULL;
ea.szProfile = szProfile; ea.szDatabase = szDatabase; ea.szLog = szLogFile; ea.Area = Area;
//
// this is the progress call back dialog which
// will be passed to SCE client stub for progress
// callback
//
AreaProgress *ap = new AreaProgress; if ( ap ) {
CString strTitle; CString strVerb; strTitle.LoadString(IDS_CONFIGURE_PROGRESS_TITLE); strVerb.LoadString(IDS_CONFIGURE_PROGRESS_VERB);
ap->Create(IDD_ANALYZE_PROGRESS); ap->SetWindowText(strTitle); ap->SetDlgItemText(IDC_VERB,strVerb); ap->ShowWindow(SW_SHOW); bRangeSet = FALSE; }
ea.pCallback = (PSCE_AREA_CALLBACK_ROUTINE)PostProgressArea; ea.hWndCallback = (HANDLE)ap;
hThread = CreateThread(NULL,0,ApplyTemplateEx,&ea,0,NULL);
DWORD dw=0; if ( hThread ) {
MSG msg;
DWORD dwTotalTicks=100; do {
dw = MsgWaitForMultipleObjects(1,&hThread,0,INFINITE,QS_ALLINPUT); while (PeekMessage(&msg,NULL,0,0,PM_REMOVE)) { TranslateMessage(&msg); DispatchMessage(&msg); } } while (WAIT_OBJECT_0 != dw);
GetExitCodeThread(hThread,&dw);
CloseHandle(hThread);
} else {
dw = GetLastError();
CString str; str.LoadString(IDS_CANT_CREATE_THREAD); AfxMessageBox(str); }
//
// free the dialog if it's created
//
if ( ap ) { if ( ap->GetSafeHwnd() ) ap->DestroyWindow(); delete ap; }
return dw; }
//
// post progress
//
BOOL PostProgressArea( IN HANDLE CallbackHandle, IN AREA_INFORMATION Area, IN DWORD TotalTicks, IN DWORD CurrentTicks ) { if ( CallbackHandle ) {
AreaProgress *ap = (AreaProgress *)CallbackHandle;
ap->ShowWindow(SW_SHOW);
if ( !bRangeSet ) { ap->SetMaxTicks(TotalTicks); bRangeSet = TRUE; } ap->SetCurTicks(CurrentTicks); ap->SetArea(Area);
return TRUE;
} else {
return FALSE; } }
//
// inspect a system
//
DWORD InspectSystem( LPCWSTR szProfile, LPCWSTR szDatabase, LPCWSTR szLogFile, AREA_INFORMATION Area ) { // Spawn a thread to call the engine & inspect the system, since this can
// take a while and we want to stay responsive & have a change to provide
// feedback.
ENGINEARGS ea; HANDLE hThread=NULL;
ea.szProfile = szProfile; ea.szDatabase = szDatabase; ea.szLog = szLogFile; ea.Area = Area;
AreaProgress *ap = new AreaProgress; if ( ap ) {
ap->Create(IDD_ANALYZE_PROGRESS); ap->ShowWindow(SW_SHOW); bRangeSet = FALSE; }
ea.pCallback = (PSCE_AREA_CALLBACK_ROUTINE)PostProgressArea; ea.hWndCallback = (HANDLE)ap;
// return InspectSystemEx(&ea);
hThread = CreateThread(NULL,0,InspectSystemEx,&ea,0,NULL); if (!hThread) { DWORD rc = GetLastError();
CString str; str.LoadString(IDS_CANT_CREATE_THREAD); AfxMessageBox(str); // Display an error
if ( ap ) { if ( ap->GetSafeHwnd() ) ap->DestroyWindow(); delete ap; } return rc; }
MSG msg; DWORD dw=0;
DWORD dwTotalTicks=100; int n = 0; do { dw = MsgWaitForMultipleObjects(1,&hThread,0,100,QS_ALLINPUT); while (PeekMessage(&msg,NULL,0,0,PM_REMOVE)) { TranslateMessage(&msg); DispatchMessage(&msg); }
} while (WAIT_OBJECT_0 != dw);
GetExitCodeThread(hThread,&dw);
CloseHandle(hThread);
if ( ap ) { if ( ap->GetSafeHwnd() ) ap->DestroyWindow(); delete ap; }
return dw;
}
BOOL GetProfileDescription(LPCTSTR ProfileName, LPWSTR* Description) // Description must be freed by LocalFree
// This should only be called for INF format profiles
{ PVOID hProfile=NULL; SCESTATUS rc;
if (EngineOpenProfile(ProfileName,OPEN_PROFILE_CONFIGURE,&hProfile) == SCESTATUS_SUCCESS) { rc = SceGetScpProfileDescription( hProfile, Description);
SceCloseProfile(&hProfile);
if ( rc == SCESTATUS_SUCCESS ) { return(TRUE); } else { return(FALSE); } } else { return FALSE; } }
SCESTATUS EngineOpenProfile( LPCWSTR FileName OPTIONAL, int format, PVOID* hProfile ) { SCESTATUS status; ENGINEARGS ea; DWORD dw; HANDLE hThread=NULL; CString str;
if ( !hProfile ) { // do not check !FileName because it's optional now
return SCESTATUS_PROFILE_NOT_FOUND; }
if ( (OPEN_PROFILE_LOCALPOL != format) && !FileName ) { return SCESTATUS_PROFILE_NOT_FOUND; }
ZeroMemory(&ea, sizeof( ENGINEARGS ) );
// This is multithreaded for responsiveness, since a
// crashed jet database can take forever and a day to open.
// If we can open it quickly (where quickly is defined as within
// OPEN_DATABASE_TIMEOUT milliseconds then
if ( (OPEN_PROFILE_ANALYSIS == format) || (OPEN_PROFILE_LOCALPOL == format)) {// JET {
ea.szProfile = FileName; ea.pHandle = hProfile; if (OPEN_PROFILE_LOCALPOL == format) { ea.dwFlags = SCE_JET_FORMAT; } else { ea.dwFlags = SCE_JET_ANALYSIS_REQUIRED; }
#if SPAWN_OPEN_DATABASE_THREAD
hThread = CreateThread(NULL,0,OpenDatabaseEx,&ea,0,NULL);
if ( hThread ) {
dw = MsgWaitForMultipleObjects(1,&hThread,0,OPEN_DATABASE_TIMEOUT,0); if (WAIT_TIMEOUT == dw) { status = SCESTATUS_OTHER_ERROR; } else { GetExitCodeThread(hThread,&status); }
CloseHandle(hThread);
} else { status = GetLastError(); } #else
status = OpenDatabaseEx(&ea); #endif
if( status != SCESTATUS_SUCCESS && *hProfile ){ status = SCESTATUS_INVALID_DATA; }
} else { // INF
status = SceOpenProfile( FileName, SCE_INF_FORMAT, hProfile ); }
if ( status != SCESTATUS_SUCCESS ){ *hProfile = NULL; }
return status; }
void EngineCloseProfile(PVOID* hProfile) { if ( hProfile ) { SceCloseProfile(hProfile); } }
BOOL EngineGetDescription(PVOID hProfile, LPWSTR* Desc) { if ( SceGetScpProfileDescription( hProfile, Desc) != SCESTATUS_SUCCESS ) { return FALSE; } else { return TRUE; } }
BOOL IsDomainController( LPCTSTR pszComputer ) { //
// for remote computers, connect to the remote registry
// currently this api only works for local computer
//
SCE_SERVER_TYPE ServerType = SCESVR_UNKNOWN; SCESTATUS rc = SceGetServerProductType((LPTSTR)pszComputer, &ServerType); return ( (SCESTATUS_SUCCESS == rc) && (SCESVR_DC_WITH_DS == ServerType) ); }
|