Leaked source code of windows server 2003
You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
|
|
@REM ----------------------------------------------------------------- @REM @REM makewinpeimg.cmd - VijayJ @REM Create the images for the WinPE CD @REM @REM Copyright (c) Microsoft Corporation. All rights reserved. @REM @REM ----------------------------------------------------------------- @if defined _CPCMAGIC goto CPCBegin @perl -x "%~f0" %* @goto :EOF #!perl use strict; use lib $ENV{RAZZLETOOLPATH} . "\\PostBuildScripts"; use lib $ENV{RAZZLETOOLPATH}; use PbuildEnv; use ParseArgs;
sub Usage { print<<USAGE; exit(1) } makewinpeimg [-l <language>]
Create the images for the WinPE CD USAGE
parseargs('?' => \&Usage);
# *** NEXT FEW LINES ARE TEMPLATE *** $ENV{"_CPCMAGIC"}++;exit(system($0)>>8); __END__ :CPCBegin set _CPCMAGIC= setlocal ENABLEDELAYEDEXPANSION ENABLEEXTENSIONS
REM REM *** BEGIN YOUR CMD SCRIPT BELOW *** REM
@echo off REM REM Set local variable's state REM set WINPEBUILDERROR=0 set OldCurrentDirectory=%cd%
REM REM We only create winpe images on fre builds REM if /i "%_BuildType%" == "chk" ( goto :winpe_done )
echo. echo --------------------------------------- echo Beginning WinPE image generation echo --------------------------------------- echo. call logmsg.cmd /t "Beginning WinPE image generation"
REM REM Create the temporary build directory REM call logmsg.cmd "Copying the required WinPE build tools..."
if exist %_NTPOSTBLD%\winpe.build ( rd %_NTPOSTBLD%\winpe.build /s /q )
md %_NTPOSTBLD%\winpe.build cd /d %_NTPOSTBLD%\winpe.build
if errorlevel 1 ( call logmsg.cmd "Error in setting up WinPE build directory" goto :winpe_error )
REM REM Copy the required tools to build WinPE in the temporaray REM build directory REM copy %_NTPOSTBLD%\opk\winpe\* 2>1>nul
if not errorlevel 1 ( copy %_NTPOSTBLD%\opk\tools\%_BUILDARCH%\* 2>1>nul )
if errorlevel 1 ( call logmsg.cmd "Error in copying the WinPE build tools" goto :winpe_error )
REM REM Make sure we are using the tools from <root>\tools\<architecture> REM del bldhives.exe del oemmint.exe
REM REM Now go ahead and create the WinPE image REM call logmsg.cmd "Creating the WinPE image..." call mkimg.cmd "%_NTPOSTBLD%\ads" "%_NTPOSTBLD%\WINPE" > "%_NTPOSTBLD%\build_logs\winpebuild.log"
REM REM Link back the WinPE folder under OPK folder so that we have a self sufficient REM OPK CD with WinPE. REM if not errorlevel 1 ( call logmsg.cmd "Linking the WinPE image to OPK CD..." call compdir.exe /deklnstuw "%_NTPOSTBLD%\WINPE" "%_NTPOSTBLD%\opk" >> "%_NTPOSTBLD%\build_logs\winpebuild.log"
REM REM Rename startopk.cmd as startnet.cmd for OPK WinPE CD. REM
if not errorlevel 1 (
if /i "%_BuildArch%" == "ia64" ( del "%_NTPOSTBLD%\opk\ia64\system32\startnet.cmd" 2>1>nul copy "%_NTPOSTBLD%\opk\winpe\startopk.cmd" "%_NTPOSTBLD%\opk\ia64\system32\startnet.cmd" 2>1>nul ) else if /i "%_BuildArch%" == "amd64" ( del "%_NTPOSTBLD%\opk\amd64\system32\startnet.cmd" 2>1>nul copy "%_NTPOSTBLD%\opk\winpe\startopk.cmd" "%_NTPOSTBLD%\opk\amd64\system32\startnet.cmd" 2>1>nul ) else if /i "%_BuildArch%" == "x86" ( del "%_NTPOSTBLD%\opk\i386\system32\startnet.cmd" 2>1>nul copy "%_NTPOSTBLD%\opk\winpe\startopk.cmd" "%_NTPOSTBLD%\opk\i386\system32\startnet.cmd" 2>1>nul )
)
)
:winpe_error set WINPEBUILDERROR=%errorlevel%
REM REM Remove the build directory REM call logmsg.cmd "Removing WinPE build directory..." cd /d %OldCurrentDirectory%
if exist %_NTPOSTBLD%\winpe.build ( rd %_NTPOSTBLD%\winpe.build /s /q )
call logmsg.cmd /t "Done with WinPE image generation" echo. echo --------------------------------------- echo Done with WinPE image generation echo --------------------------------------- echo.
:winpe_done seterror.exe "%WINPEBUILDERROR%"
|