Leaked source code of windows server 2003
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

111 lines
3.2 KiB

/*---------------------------------------------------------------------------
File: RebootComputer.cpp
Comments: Implementation of COM object to reboot a remote computer.
(c) Copyright 1999, Mission Critical Software, Inc., All Rights Reserved
Proprietary and confidential to Mission Critical Software, Inc.
REVISION LOG ENTRY
Revision By: Christy Boles
Revised on 02/15/99 11:21:40
---------------------------------------------------------------------------
*/
// RebootComputer.cpp : Implementation of CRebootComputer
#include "stdafx.h"
#include "WorkObj.h"
#include "Reboot.h"
#include "UString.hpp"
#include "ResStr.h"
//#import "\bin\McsVarSetMin.tlb" no_namespace
#import "VarSet.tlb" no_namespace rename("property", "aproperty")
/////////////////////////////////////////////////////////////////////////////
// CRebootComputer
#include "BkupRstr.hpp"
STDMETHODIMP
CRebootComputer::Reboot(
BSTR Computer, // in - name of computer to reboot
DWORD delay // in - delay in seconds before rebooting
)
{
HRESULT hr = S_OK;
DWORD rc;
rc = ComputerShutDown((WCHAR*)Computer,NULL,delay,TRUE,m_bNoChange);
if ( rc )
{
hr = HRESULT_FROM_WIN32(rc);
}
return hr;
}
STDMETHODIMP
CRebootComputer::get_NoChange(
BOOL * pVal // out- flag, whether to actually reboot when reboot is called (or to do dry-run)
)
{
(*pVal) = m_bNoChange;
return S_OK;
}
STDMETHODIMP
CRebootComputer::put_NoChange(
BOOL newVal // in - flag, whether to really reboot, or to do a dry run
)
{
m_bNoChange = newVal;
return S_OK;
}
// RebootComputer WorkNode: Reboots a remote computer, with an optional delay
// This function is not currently used by the domain migrator product, but provides
// and alternate way for clients to use this COM object
//
// VarSet Syntax:
// Input:
// RebootComputer.Computer: <ComputerName>
// RebootComputer.Message: <Message> (optional)
// RebootComputer.Delay: <number-of-seconds> (optional, default=0)
// RebootComputer.Restart: <Yes|No> (optional, default=Yes)
STDMETHODIMP
CRebootComputer::Process(
IUnknown * pWorkItem // in - varset containing settings
)
{
HRESULT hr = S_OK;
IVarSetPtr pVarSet = pWorkItem;
DWORD delay = 0;
BOOL restart = TRUE;
_bstr_t computer = pVarSet->get(L"RebootComputer.Computer");
_bstr_t message = pVarSet->get(L"RebootComputer.Message");
_bstr_t text = pVarSet->get(L"RebootComputer.Restart");
if ( !UStrICmp(text,GET_STRING(IDS_No)) )
{
restart = FALSE;
}
delay = (LONG)pVarSet->get(L"RebootComputer.Delay");
if ( computer.length() )
{
DWORD rc = ComputerShutDown((WCHAR*)computer,(WCHAR*)message,delay,restart,FALSE);
if ( rc )
{
hr = HRESULT_FROM_WIN32(rc);
}
}
return hr;
}