/* DEMOUPS - UPS Minidriver Sample
* Copyright (C) Microsoft Corporation, 2001, All rights reserved.
* Copyright (C) American Power Conversion, 2001, All rights reserved.
*
* THIS CODE AND INFORMATION IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY
* KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR
* PURPOSE.
*
* File: demoups.cpp
*
* Author: Stephen Berard
*
* Description:
* Demo UPS Minidriver implementation. This minidriver provides
* a basic framework for a UPS Minidriver.
*
* Revision History:
* 26Jun2001 Created
*/
#include <windows.h>
#include "demoups.h"
// Global value used to indicate that the UPS state has changed
HANDLE theStateChangedEvent;
// Global handle to DLL module
HINSTANCE theDLLModuleHandle;
/**
* DllMain
*
* Description:
* This method is called when the DLL is loaded or unloaded.
*
* Parameters:
* aHandle: the DLL module handle
* aReason: flag indicating the reason why the entry point was called
* aReserved: reserved
*
* Returns:
* TRUE
*
*/
BOOL APIENTRY DllMain(HINSTANCE aHandle, DWORD aReason, LPVOID aReserved) {
switch (aReason) {
// DLL initialization code goes here
case DLL_PROCESS_ATTACH:
theDLLModuleHandle = aHandle;
DisableThreadLibraryCalls(theDLLModuleHandle);
break;
case DLL_THREAD_ATTACH:
case DLL_THREAD_DETACH:
case DLL_PROCESS_DETACH:
break;
}
return TRUE;
}
/**
* UPSInit
*
* Description:
* Must be the first method called in the interface. This method should do
* any initialization required and obtain the initial UPS state.
*
* Parameters:
* None
*
* Returns:
* UPS_INITOK: successful initialization
* UPS_INITUNKNOWNERROR: failed initialization
*
*/
UPSMINIDRIVER_API DWORD UPSInit() {
DWORD init_err = UPS_INITOK;
theStateChangedEvent = CreateEvent(NULL, FALSE, FALSE, NULL);
if (!theStateChangedEvent) {
init_err = UPS_INITUNKNOWNERROR;
}
return init_err;
}
/**
* UPSStop
*
* Description:
* Stops monitoring of the UPS. This method should perform any necessary
* cleanup.
*
* Parameters:
* None
*
* Returns:
* None
*
*/
UPSMINIDRIVER_API void UPSStop(void) {
UPSCancelWait();
if (theStateChangedEvent) {
CloseHandle(theStateChangedEvent);
theStateChangedEvent = NULL;
}
}
/**
* UPSWaitForStateChange
*
* Description:
* Blocks until the state of the UPS differs from the value passed in
* via aState or anInterval milliseconds has expired. If anInterval has
* a value of INFINITE this function will never timeout
*
* Parameters:
* aState: defines the state to wait for a change from,
* possible values:
* UPS_ONLINE
* UPS_ONBATTERY
* UPS_LOWBATTERY
* UPS_NOCOMM
*
* anInterval: timeout in milliseconds, or INFINITE for
* no timeout interval
*
* Returns:
* None
*
*/
UPSMINIDRIVER_API void UPSWaitForStateChange(DWORD aState, DWORD anInterval) {
// Wait for the UPS state to change. Typically a separate thread would be
// used to monitor the UPS and then set theStateChangedEvent to indicate
// that the state has changed. In this demo we only report UPS_ONLINE so
// we don't have a monitoring thread.
if (theStateChangedEvent) {
WaitForSingleObject(theStateChangedEvent, anInterval);
}
}
/**
* UPSGetState
*
* Description:
* Returns the current state of the UPS. This demo minidriver always returns
* UPS_ONLINE.
*
* Parameters:
* None
*
* Returns:
* possible values:
* UPS_ONLINE
* UPS_ONBATTERY
* UPS_LOWBATTERY
* UPS_NOCOMM
*
*/
UPSMINIDRIVER_API DWORD UPSGetState(void) {
// Determine the UPS state and return it.
// Demo UPS minidriver always returns Online
return UPS_ONLINE;
}
/**
* UPSCancelWait
*
* Description:
* Interrupts a pending calls to UPSWaitForStateChange without regard to
* timout or state change
*
* Parameters:
* None
*
* Returns:
* None
*
*/
UPSMINIDRIVER_API void UPSCancelWait(void) {
// Send a signal to interupt anything waiting.
if (theStateChangedEvent) {
SetEvent(theStateChangedEvent);
}
}
/**
* UPSTurnOff
*
* Description:
* Attempts to turn off the outlets on the UPS after the specified delay.
* This demo minidriver ignores this call and simply returns.
*
* Parameters:
* aTurnOffDelay: the minimum amount of time to wait before
* turning off the outlets on the UPS
*
* Returns:
* None
*
*/
UPSMINIDRIVER_API void UPSTurnOff(DWORD aTurnOffDelay) {
// Code to power off the UPS goes here
}