;* $ProjectName: $
|
|
;* $ProjectRevision: $
|
|
;*-----------------------------------------------------------------------------
|
|
;* $Source: z:/pr/cmapiifd/sw/sccmn50m.ms/rcs/sccmlog.mc $
|
|
;* $Revision: 1.1 $
|
|
;*-----------------------------------------------------------------------------
|
|
;* $Author: TBruendl $
|
|
;*-----------------------------------------------------------------------------
|
|
;* History: see EOF
|
|
;*-----------------------------------------------------------------------------
|
|
;*
|
|
;* Copyright © 1996-99 Utimaco Safeware AG
|
|
;******************************************************************************/
|
|
|
|
;#ifndef _SCCMLOG
|
|
;#define _SCCMLOG
|
|
;
|
|
;//
|
|
;// Status values are 32 bit values layed out as follows:
|
|
;//
|
|
;// 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
|
|
;// 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
|
|
;// +---+-+-------------------------+-------------------------------+
|
|
;// |Sev|C| Facility | Code |
|
|
;// +---+-+-------------------------+-------------------------------+
|
|
;//
|
|
;// where
|
|
;//
|
|
;// Sev - is the severity code
|
|
;//
|
|
;// 00 - Success
|
|
;// 01 - Informational
|
|
;// 10 - Warning
|
|
;// 11 - Error
|
|
;//
|
|
;// C - is the Customer code flag
|
|
;//
|
|
;// Facility - is the facility code
|
|
;//
|
|
;// Code - is the facility's status code
|
|
;//
|
|
;
|
|
MessageIdTypedef=NTSTATUS
|
|
|
|
SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS
|
|
Informational=0x1:STATUS_SEVERITY_INFORMATIONAL
|
|
Warning=0x2:STATUS_SEVERITY_WARNING
|
|
Error=0x3:STATUS_SEVERITY_ERROR
|
|
)
|
|
|
|
FacilityNames=(System=0x0
|
|
RpcRuntime=0x2:FACILITY_RPC_RUNTIME
|
|
RpcStubs=0x3:FACILITY_RPC_STUBS
|
|
Io=0x4:FACILITY_IO_ERROR_CODE
|
|
Smartcard=0x10:FACILITY_SCARD
|
|
)
|
|
|
|
MessageId=0x0001 Facility=Io Severity=Error SymbolicName=SCCMN50M_CANT_CREATE_DEVICE
|
|
Language=English
|
|
A new device cannot be created due to an system call failure.
|
|
.
|
|
MessageId=0x0002 Facility=Io Severity=Error SymbolicName=SCCMN50M_NO_MEMORY
|
|
Language=English
|
|
The system does not have enough memory.
|
|
.
|
|
MessageId=0x0003 Facility=Smartcard Severity=Error SymbolicName=SCCMN50M_BUFFER_TOO_SMALL
|
|
Language=English
|
|
An internal i/o buffer is too small.
|
|
.
|
|
MessageId=0x0004 Facility=Io Severity=Error SymbolicName=SCCMN50M_CANT_CONNECT_TO_ASSIGNED_PORT
|
|
Language=English
|
|
Internal error: Cannot connect to assigned serial port.
|
|
.
|
|
MessageId=0x0005 Facility=Io Severity=Error SymbolicName=SCCMN50M_CANT_CREATE_MORE_DEVICES
|
|
Language=English
|
|
The maximum number of devices has already been created.
|
|
A new device cannot be created.
|
|
.
|
|
MessageId=0x0006 Facility=Io Severity=Informational SymbolicName=SCCMN50M_WRONG_LIB_VERSION
|
|
Language=English
|
|
The version of the dependency driver smclib.sys is not compatbile to this driver.
|
|
.
|
|
MessageId=0x0007 Facility=Io Severity=Informational SymbolicName=SCCMN50M_IRQ_BUSY
|
|
Language=English
|
|
The current serial port cannot be used because it uses a shared interrupt which is already in use.
|
|
Please connect the smart card reader to a different serial port.
|
|
.
|
|
;#endif /* _SCCMLOG */
|
|
|
|
;/*****************************************************************************
|
|
;* History:
|
|
;* $Log: sccmlog.mc $
|
|
;* Revision 1.1 2000/03/29 06:07:48 TBruendl
|
|
;* No comment given
|
|
;*
|
|
;* Revision 1.1 1999/02/02 13:34:38 TBruendl
|
|
;* This is the first release (R01.00) of the IFD handler for CardMan running under NT5.0.
|
|
;*
|
|
;*
|
|
;*****************************************************************************/
|
|
|