Leaked source code of windows server 2003
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

195 lines
5.6 KiB

// EdtRulEl.cpp : implementation file
//
#include "stdafx.h"
#include "certmap.h"
#include "EdtRulEl.h"
extern "C"
{
#include <wincrypt.h>
#include <schannel.h>
}
#include "Iismap.hxx"
#include "Iiscmr.hxx"
#ifdef _DEBUG
#define new DEBUG_NEW
#undef THIS_FILE
static char THIS_FILE[] = __FILE__;
#endif
/////////////////////////////////////////////////////////////////////////////
// CEditRuleElement dialog
//---------------------------------------------------------------------------
CEditRuleElement::CEditRuleElement(CWnd* pParent /*=NULL*/)
: CDialog(CEditRuleElement::IDD, pParent)
{
//{{AFX_DATA_INIT(CEditRuleElement)
m_sz_criteria = _T("");
m_int_field = -1;
m_sz_subfield = _T("");
m_bool_match_case = FALSE;
//}}AFX_DATA_INIT
}
//---------------------------------------------------------------------------
void CEditRuleElement::DoDataExchange(CDataExchange* pDX)
{
CDialog::DoDataExchange(pDX);
//{{AFX_DATA_MAP(CEditRuleElement)
DDX_Control(pDX, IDC_SUBFIELD, m_ccombobox_subfield);
DDX_Control(pDX, IDC_FIELDS, m_ccombobox_field);
DDX_Text(pDX, IDC_CRITERIA, m_sz_criteria);
DDX_CBIndex(pDX, IDC_FIELDS, m_int_field);
DDX_CBString(pDX, IDC_SUBFIELD, m_sz_subfield);
DDX_Check(pDX, IDC_CHK_CAPITALIZATION, m_bool_match_case);
//}}AFX_DATA_MAP
}
//---------------------------------------------------------------------------
BEGIN_MESSAGE_MAP(CEditRuleElement, CDialog)
//{{AFX_MSG_MAP(CEditRuleElement)
ON_CBN_SELCHANGE(IDC_FIELDS, OnSelchangeFields)
ON_EN_CHANGE(IDC_SUBFIELD, OnChangeSubfield)
ON_BN_CLICKED(IDC_BTN_HELP, OnBtnHelp)
//}}AFX_MSG_MAP
ON_COMMAND(ID_HELP_FINDER, OnBtnHelp)
ON_COMMAND(ID_HELP, OnBtnHelp)
ON_COMMAND(ID_CONTEXT_HELP, OnBtnHelp)
ON_COMMAND(ID_DEFAULT_HELP, OnBtnHelp)
END_MESSAGE_MAP()
/////////////////////////////////////////////////////////////////////////////
// CEditRuleElement message handlers
//---------------------------------------------------------------------------
BOOL CEditRuleElement::OnInitDialog()
{
CString sz;
// call the parental oninitdialog
BOOL f = CDialog::OnInitDialog();
// initialize the elements in the drop-list
// loop the list of CERT_FIELD_IDs, adding each to the drop-list
for ( UINT id = CERT_FIELD_ISSUER; id < CERT_FIELD_LAST; id++ )
{
// bug 154957 requests that we no longer support mapping on the
// serial number. This makes sense anyway as mapping to the serial
// numbers is better off done as 1::1 mapping. If the bug doesn't
// make this conclusion clear enough upon reading, it is the
// interpretation that MikeHow has handed down.
if ( id == CERT_FIELD_SERIAL_NUMBER )
continue;
// get the string associated with the id
sz = MapIdToField( (CERT_FIELD_ID)id );
m_ccombobox_field.AddString( sz );
}
// initialize the list of known subfields
id = 0;
//
// UNICODE conversion -- RonaldM
//
LPCSTR psz;
while ( psz = EnumerateKnownSubFields(id) )
{
CString str(psz);
// append it to the drop-list
m_ccombobox_subfield.AddString( str );
// increment id
id++;
}
UpdateData( FALSE );
// store the initial value of the sub-field
m_szTempSubStorage = m_sz_subfield;
// make sure to check the subfields
OnSelchangeFields();
// return the answer
return f;
}
//---------------------------------------------------------------------------
// make sure that, if there is a sub-field, that it is valid
//
void CEditRuleElement::OnOK()
{
UpdateData( TRUE );
//
// UNICODE/ANSI conversion - RonaldM
//
USES_CONVERSION;
// test the sub-field flag for the newly selected field type
DWORD flags = GetIdFlags( (CERT_FIELD_ID)m_int_field );
BOOL fSubs = flags & CERT_FIELD_FLAG_CONTAINS_SUBFIELDS;
// if there are sub-fields, test their validity
if ( fSubs )
{
CString szTest(MapSubFieldToAsn1( T2A((LPTSTR)(LPCTSTR)m_sz_subfield) ));
// if there is NO match, tell the user
if ( szTest.IsEmpty() )
{
AfxMessageBox( IDS_INVALID_SUBFIELD );
return;
}
}
// it is valid
CDialog::OnOK();
}
//---------------------------------------------------------------------------
void CEditRuleElement::OnSelchangeFields()
{
UpdateData( TRUE );
// test the sub-field flag for the newly selected field type
DWORD flags = GetIdFlags( (CERT_FIELD_ID)m_int_field );
BOOL fSubs = flags & CERT_FIELD_FLAG_CONTAINS_SUBFIELDS;
// set the correct enable state
BOOL fWasEnabled = m_ccombobox_subfield.EnableWindow( fSubs );
// restore the value if necessary
if ( fSubs )
{
m_sz_subfield = m_szTempSubStorage;
UpdateData( FALSE );
}
else
{
m_szTempSubStorage = m_sz_subfield;
m_sz_subfield.Empty();
UpdateData( FALSE );
}
}
//---------------------------------------------------------------------------
void CEditRuleElement::OnChangeSubfield()
{
m_szTempSubStorage = m_sz_subfield;
}
//---------------------------------------------------------------------------
void CEditRuleElement::OnBtnHelp()
{
WinHelpDebug( HIDD_CERTMAP_RUL_ELEMENT );
WinHelp( HIDD_CERTMAP_RUL_ELEMENT );
}