You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
71 lines
2.6 KiB
71 lines
2.6 KiB
/*---------------------------------------------------
|
|
Copyright (c) 1998, Microsoft Corporation
|
|
File: timerval.h
|
|
|
|
Purpose:
|
|
Contains H.323 related timer values. Timer values are only
|
|
used to clean up state in case of client error and are not
|
|
aggressive.
|
|
|
|
History:
|
|
|
|
1. created as cb931pdu.h for q931 consts (rajeevb, 19-Jun-1998)
|
|
2. now contains all timer values for q931 and h245 (rajeevb, 19-Jun-1998)
|
|
|
|
---------------------------------------------------*/
|
|
#ifndef __CB_TIMER_H__
|
|
#define __CB_TIMER_H__
|
|
|
|
// timers defined below are in seconds and indicate
|
|
// the number of seconds to wait before attempting to
|
|
// cleanup
|
|
// these are only loosely based on the H.323 specs in that
|
|
// they are only used to clean-up state and give a long leash
|
|
// to callee's in responding to messages (more than the spec)
|
|
|
|
#ifndef DBG
|
|
// we wait for the callee to respond
|
|
// to a SETUP PDU, we wait for a
|
|
// CALL PROCEEDING, ALERTING, CONNECT or RELEASE COMPLETE PDU
|
|
// the H.225 spec suggests that the caller wait for 4s
|
|
const DWORD Q931_POST_SETUP_TIMER_VALUE = 60000; // 1min
|
|
|
|
// we wait for the callee to respond
|
|
// to a CALL PROCEEDING PDU, we wait for an
|
|
// ALERTING, CONNECT or RELEASE COMPLETE PDU
|
|
// the H.225 spec doesn't define the time to wait for this
|
|
const DWORD Q931_POST_CALL_PROC_TIMER_VALUE = 600000; // 10mins
|
|
|
|
// we wait for the callee to respond
|
|
// to an ALERTING PDU, we wait for a
|
|
// CONNECT or RELEASE COMPLETE PDU
|
|
// the H.225 spec suggests 180s (3mins) of wait for this
|
|
const DWORD Q931_POST_ALERTING_TIMER_VALUE = 600000; // 10mins
|
|
|
|
// we wait for the callee to respond
|
|
// to an OPEN LOGICAL CHANNEL PDU, we wait for a
|
|
// OPEN LOGICAL CHANNEL ACK/REJECT PDU from the callee
|
|
// the caller may send a CLOSE LOGICAL CHANNEL PDU in the meantime
|
|
// which would cause this to be reset
|
|
// I (rajeevb) couldn't find H.245 spec suggestion for this
|
|
const DWORD LC_POST_OPEN_TIMER_VALUE = 600000; // 10mins
|
|
|
|
// we wait for the callee to respond
|
|
// to an CLOSE LOGICAL CHANNEL PDU, we wait for a
|
|
// CLOSE LOGICAL CHANNEL ACK PDU from the callee
|
|
// I (rajeevb) couldn't find H.245 spec suggestion for this
|
|
const DWORD LC_POST_CLOSE_TIMER_VALUE = 600000; // 10mins
|
|
|
|
#else // DBG
|
|
|
|
// Feel free to play around with the Timer values here
|
|
|
|
const DWORD Q931_POST_SETUP_TIMER_VALUE = 60000; // 1min
|
|
const DWORD Q931_POST_CALL_PROC_TIMER_VALUE = 60000; //600000; // 10mins
|
|
const DWORD Q931_POST_ALERTING_TIMER_VALUE = 60001; //600001; // 10mins
|
|
const DWORD LC_POST_OPEN_TIMER_VALUE = 600000; // 10mins
|
|
const DWORD LC_POST_CLOSE_TIMER_VALUE = 600001; // 10mins
|
|
|
|
#endif // DBG
|
|
|
|