[Responses]
|
|
; This section is temporary.
|
|
|
|
;-----------------------------------------------------------------------------
|
|
[SprintNet, Standard]
|
|
|
|
DEFAULTOFF=
|
|
MAXCARRIERBPS=9600
|
|
MAXCONNECTBPS=9600
|
|
|
|
|
|
; The next two lines ignore logon banners
|
|
COMMAND=
|
|
OK=<ignore>
|
|
|
|
|
|
; The @ characters sets the SprintNet PAD for 8 databit communication.
|
|
COMMAND=@
|
|
NoResponse
|
|
|
|
|
|
; The D character requests a 9600 speed.
|
|
COMMAND=D<cr>
|
|
; We dont care about the response so we ignore it (unless modem has hung up).
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
; A carriage return to initialize the PAD read/write buffers
|
|
COMMAND=<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
; Set X.3 settings on the PAD which make it work well with RAS. Broken into
|
|
; two parts since the line is too long.
|
|
COMMAND=SET 1:0,2:0,3:0,4:1,5:0,6:1,7:0,8:0,9:0,10:0<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
; Set the other half of X.3 parameters
|
|
COMMAND=SET 12:0,13:0,14:0,15:0,16:0,17:0,18:0,19:0,20:0,22:0<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
; Finally try to call RAS X25 server
|
|
COMMAND=C <x25address>*<UserData><cr>
|
|
|
|
CONNECT=<match>" CONNECT"
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
|
|
ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
|
|
|
|
|
|
; CONNECT response means that the connection completed fine.
|
|
; ERROR_DIAGNOISTICS response means connection attempt failed - the X25
|
|
; DIAGNOSTIC information will be extracted from the response and sent to the
|
|
; user.
|
|
; ERROR_NO_CARRIER means that the remote modem hung up.
|
|
; ERROR resonses are for generic failures.
|
|
|
|
;-----------------------------------------------------------------------------
|
|
[SprintNet, Alternate]
|
|
|
|
; Connections can be made more reliably in some SprintNet locations if
|
|
; there are some delays near the beginning of the pad.inf entry. As a
|
|
; general rule of thumb use this entry with older, slower (2400 bps)
|
|
; locations.
|
|
|
|
|
|
DEFAULTOFF=
|
|
MAXCARRIERBPS=9600
|
|
MAXCONNECTBPS=9600
|
|
|
|
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
|
|
; The @ characters sets the SprintNet PAD for 8 databit communication.
|
|
COMMAND=@
|
|
NoResponse
|
|
|
|
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
|
|
; The D character requests a 9600 speed.
|
|
COMMAND=D<cr>
|
|
; We dont care about the response so we ignore it (unless modem has hung up).
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
; A carriage return to initialize the PAD read/write buffers
|
|
COMMAND=<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
; Set X.3 settings on the PAD which make it work well with RAS. Broken into
|
|
; two parts since the line is too long.
|
|
COMMAND=SET 1:0,2:0,3:0,4:1,5:0,6:1,7:0,8:0,9:0,10:0<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
; Set the other half of X.3 parameters
|
|
COMMAND=SET 12:0,13:0,14:0,15:0,16:0,17:0,18:0,19:0,20:0,22:0<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
; Finally try to call RAS X25 server
|
|
COMMAND=C <x25address>*<UserData><cr>
|
|
|
|
CONNECT=<match>" CONNECT"
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
|
|
ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
|
|
|
|
|
|
; CONNECT response means that the connection completed fine.
|
|
; ERROR_DIAGNOISTICS response means connection attempt failed - the X25
|
|
; DIAGNOSTIC information will be extracted from the response and sent to the
|
|
; user.
|
|
; ERROR_NO_CARRIER means that the remote modem hung up.
|
|
; ERROR resonses are for generic failures.
|
|
|
|
;-----------------------------------------------------------------------------
|
|
[InfoNet]
|
|
|
|
DEFAULTOFF=
|
|
MAXCARRIERBPS=2400
|
|
MAXCONNECTBPS=2400
|
|
|
|
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
|
|
COMMAND=<cr>
|
|
; We dont care about the response so we ignore it (unless modem has hung up).
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
COMMAND=<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
COMMAND=X<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
; Set X.3 settings on the PAD which make it work well with RAS. Broken into
|
|
; two parts since the line is too long.
|
|
COMMAND=SET 1:126,2:1,3:0,4:1,5:0,6:1,7:0,8:0,9:0,10:0<cr>
|
|
NoResponse
|
|
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
; Set the other half of X.3 parameters
|
|
COMMAND=SET 12:0,13:0,14:0,15:0,16:0,17:0,18:0,19:0,20:0,21:0,22:0<cr>
|
|
NoResponse
|
|
|
|
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
; Try to call RAS X25 server
|
|
COMMAND=<x25address><cr><lf>
|
|
|
|
OK=<match>"COM"
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
|
|
|
|
|
|
; CONNECT response means that the connection completed fine.
|
|
; ERROR_DIAGNOISTICS response means connection attempt failed - the X25
|
|
; DIAGNOSTIC information will be extracted from the response and sent
|
|
; to the user.
|
|
; ERROR_NO_CARRIER means that the remote modem hung up.
|
|
; ERROR resonses are for generic failures.
|
|
|
|
|
|
; Finally set no escape and no echo
|
|
COMMAND=SET 1:0,2:0<cr>
|
|
NoResponse
|
|
|
|
;-----------------------------------------------------------------------------
|
|
[InfoNet, Alternate]
|
|
|
|
DEFAULTOFF=
|
|
MAXCARRIERBPS=9600
|
|
MAXCONNECTBPS=9600
|
|
|
|
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
|
|
COMMAND=<cr>
|
|
; We dont care about the response so we ignore it (unless modem has hung up).
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
COMMAND=<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
COMMAND=X<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
; Set X.3 settings on the PAD which make it work well with RAS. Broken into
|
|
; two parts since the line is too long.
|
|
;COMMAND=SET 1:126,2:1,3:0,4:1,5:0,6:1,7:0,8:0,9:0,10:0<cr>
|
|
COMMAND=SET 1:126,2:1,3:0,4:1,5:0,6:1,7:2,9:0,10:0<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR=<match>"ERR"
|
|
OK=<ignore>
|
|
|
|
|
|
; Set the other half of X.3 parameters
|
|
COMMAND=SET 12:0,13:0,14:0,15:0,16:127,17:24,18:18,19:0,20:0,21:0,22:0<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR=<match>"ERR"
|
|
OK=<ignore>
|
|
|
|
; Try to call RAS X25 server
|
|
COMMAND=<x25address><cr><lf>
|
|
OK=<ignore>
|
|
|
|
OK=<match>"COM"
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
|
|
ERROR=<match>"ERR"
|
|
|
|
|
|
; CONNECT response means that the connection completed fine.
|
|
; ERROR_DIAGNOISTICS response means connection attempt failed - the X25
|
|
; DIAGNOSTIC information will be extracted from the response and sent
|
|
; to the user.
|
|
; ERROR_NO_CARRIER means that the remote modem hung up.
|
|
; ERROR resonses are for generic failures.
|
|
|
|
|
|
; Finally set no escape and no echo
|
|
COMMAND=SET 1:0,2:0<cr>
|
|
NoEcho
|
|
ERROR=<match>"ERR"
|
|
CONNECT=<ignore>
|
|
|
|
[Transpac]
|
|
|
|
DEFAULTOFF=
|
|
MAXCARRIERBPS=2400
|
|
MAXCONNECTBPS=2400
|
|
|
|
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
; We dont care about the response so we ignore it (unless modem has hung up).
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<match>"TRANSPAC"
|
|
|
|
; Set X.3 settings on the PAD which make it work well with RAS. Broken into
|
|
; two parts since the line is too long.
|
|
COMMAND=SET 1:1,2:1,3:0,4:1,5:0,6:1,7:0,9:0,10:0<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR=<match>"ERR"
|
|
OK=<ignore>
|
|
|
|
|
|
; Set the other half of X.3 parameters
|
|
COMMAND=SET 12:0,13:0,14:0,15:0,16:127,17:24,18:18,19:0,20:0,21:0,22:0<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR=<match>"ERR"
|
|
OK=<ignore>
|
|
|
|
; Try to call RAS X25 server
|
|
COMMAND=<x25address><cr><lf>
|
|
OK=<ignore>
|
|
|
|
OK=<match>"COM"
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
|
|
|
|
|
|
; CONNECT response means that the connection completed fine.
|
|
; ERROR_DIAGNOISTICS response means connection attempt failed - the X25
|
|
; DIAGNOSTIC information will be extracted from the response and sent
|
|
; to the user.
|
|
; ERROR_NO_CARRIER means that the remote modem hung up.
|
|
; ERROR resonses are for generic failures.
|
|
|
|
|
|
; Finally set no escape and no echo
|
|
COMMAND=SET 1:0,2:0<cr>
|
|
NoEcho
|
|
CONNECT=<ignore>
|
|
|
|
|
|
;-----------------------------------------------------------------------------
|
|
[Eicon X.PAD]
|
|
|
|
DEVICETYPE=pad
|
|
DEFAULTOFF=
|
|
|
|
MAXCARRIERBPS=1200
|
|
MAXCONNECTBPS=1200
|
|
|
|
;
|
|
; INIT section.
|
|
;
|
|
COMMAND_INIT=PAR 2<cr>
|
|
NoEcho
|
|
OK=par 2:<ignore>
|
|
ERROR_DIAGNOSTICS=CLR <Diagnostics>
|
|
ERROR=ERR<ignore>
|
|
|
|
;
|
|
; LISTEN section.
|
|
;
|
|
COMMAND_LISTEN=
|
|
NoEcho
|
|
CONNECT=<match>"COM"
|
|
ERROR_DIAGNOSTICS=CLR <Diagnostics>
|
|
ERROR=ERR<ignore>
|
|
|
|
;
|
|
; CALL section.
|
|
;
|
|
COMMAND_DIAL=<x25address><cr><lf>
|
|
NoEcho
|
|
CONNECT=<match>"COM"
|
|
ERROR_DIAGNOSTICS=CLR CONF <cr><lf>CLR<Diagnostics>
|
|
ERROR_DIAGNOSTICS=CLR <Diagnostics>
|
|
ERROR=ERR<ignore>
|
|
|
|
;-----------------------------------------------------------------------------
|
|
[Compuserve]
|
|
|
|
; Disclaimer:
|
|
; This script has been included for customer convenience, but has NOT been
|
|
; fully verified to work under all circumstances. Microsoft makes NO guarantees
|
|
; as to the performance of this script. Please contact Microsoft
|
|
; PSS NT support if you have problems or questions.
|
|
|
|
DEFAULTOFF=
|
|
MAXCARRIERBPS=9600
|
|
MAXCONNECTBPS=9600
|
|
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
COMMAND=<cr>
|
|
OK=<ignore>
|
|
|
|
COMMAND=+<cr>
|
|
OK=<match>"Host Name:"
|
|
|
|
COMMAND=<x25address><cr>
|
|
CONNECT=<match>"Connected"
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
|
|
ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
|
|
|
|
|
|
;-----------------------------------------------------------------------------------
|
|
[SITA Group Network]
|
|
|
|
; Disclaimer:
|
|
; This script has been included for customer convenience, but has NOT been
|
|
; fully verified to work under all circumstances. Microsoft makes NO guarantees
|
|
; as to the performance of this script. Please contact Microsoft
|
|
; PSS NT support if you have problems or questions.
|
|
; PLEASE SEE COMMENTS BELOW REGARDING USAGE OF THE "User Data:"
|
|
; and "Facilities:" FIELDS IN RAS WHEN USING THIS SITA SCRIPT.
|
|
|
|
DEFAULTOFF=
|
|
MAXCARRIERBPS=9600
|
|
MAXCONNECTBPS=9600
|
|
|
|
COMMAND=...<cr>
|
|
OK=<match>"SITA NETWORK:"
|
|
|
|
; Enter your NUI number in the Remote Access program's X.25 Settings "User Data:" field.
|
|
COMMAND=<UserData><cr>
|
|
OK=<ignore>
|
|
|
|
; Enter your x.25 password in the Remote Access program's X.25 Settings "Facilities:" field.
|
|
COMMAND=<Facilities><cr>
|
|
OK=<match>"active"
|
|
ERROR_DIAGNOSTICS=<cr><lf><cr><lf><lf><Diagnostics>
|
|
ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
|
|
|
|
COMMAND=PROF 6<cr>
|
|
NoResponse
|
|
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
COMMAND=SET 2:1<cr>
|
|
OK=<ignore>
|
|
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
COMMAND=SET 4:1,6:1,16:0,17:0,18:0,19:0,21:0<cr>
|
|
OK=<ignore>
|
|
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
COMMAND=SET 118:0,119:0,120:0<cr>
|
|
OK=<ignore>
|
|
|
|
COMMAND=PAR?<cr>
|
|
OK=<ignore>
|
|
|
|
COMMAND=SET 2:0<cr>
|
|
NoResponse
|
|
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
COMMAND=<x25address><cr>
|
|
CONNECT=<match>"connected"
|
|
;CONNECT=<ignore>
|
|
ERROR_DIAGNOSTICS=<cr><lf><cr><lf><lf><Diagnostics>
|
|
ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
|
|
|
|
;-----------------------------------------------------------------------------------
|
|
[Alascom/Tymnet/MCI]
|
|
|
|
; Disclaimer:
|
|
; This script has been included for customer convenience, but has NOT been
|
|
; fully verified to work under all circumstances. Microsoft makes NO guarantees
|
|
; as to the performance of this script. Please contact Microsoft
|
|
; PSS NT support if you have problems or questions.
|
|
; NOTE: Whether your X.25 account is set up for a single x.121 identifier or a
|
|
; username/password combination, they both are entered in the Remote Access program's
|
|
; "X.25 Settings" dialog box in the "X.121 Address:" field.
|
|
; A username and password combination is entered simply by separating them with a
|
|
; SEMICOLON, e.g.: John;mypass
|
|
; where "John" is the username and "mypass" is the password.
|
|
|
|
DEFAULTOFF=
|
|
MAXCARRIERBPS=9600
|
|
MAXCONNECTBPS=9600
|
|
|
|
; The "o" changes the terminal identifer so that the x.25 network responses are
|
|
; readable and don't appear as garbage. No carriage return is required after it.
|
|
COMMAND=o
|
|
OK=<match>"log in:"
|
|
ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
|
|
ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
|
|
|
|
; Note: The "<h08>" represents a Ctrl-H or Backspace character which turns the
|
|
; echo facility in the x.25 network off which interferes with RAS operation.
|
|
COMMAND=<h08><x25address><cr>
|
|
CONNECT=<match>"connected"
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
|
|
ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
|
|
|
|
[Telematics]
|
|
|
|
DEFAULTOFF=
|
|
MAXCARRIERBPS=19200
|
|
MAXCONNECTBPS=19200
|
|
|
|
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=<cr>
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=<cr>
|
|
|
|
;The next line will initiate AUTOBAUD/AUTOPARITY with the
|
|
;Telematics PAD
|
|
COMMAND=..<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<match>"*"
|
|
|
|
|
|
; Finally try to call RAS X25 server
|
|
COMMAND=<x25address><cr>
|
|
|
|
CONNECT=<match>"com"
|
|
|
|
|
|
[InfoNet X25]
|
|
|
|
DEFAULTOFF=
|
|
MAXCARRIERBPS=2400
|
|
MAXCONNECTBPS=2400
|
|
|
|
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
|
|
; The next line will give a delay of 2 secs - allowing the PAD to initialize
|
|
COMMAND=
|
|
NoResponse
|
|
|
|
|
|
COMMAND=<cr>
|
|
; We dont care about the response so we ignore it (unless modem has hung up).
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
COMMAND=<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
|
|
COMMAND=SET 2:1<cr>
|
|
NoResponse
|
|
|
|
COMMAND=X<cr>
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
OK=<ignore>
|
|
|
|
; Try to call RAS X25 server
|
|
COMMAND=<x25address><cr><lf>
|
|
|
|
OK=<match>"COM"
|
|
ERROR_NO_CARRIER=<match>"NO CARRIER"
|
|
ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
|
|
|
|
|
|
; CONNECT response means that the connection completed fine.
|
|
; ERROR_DIAGNOISTICS response means connection attempt failed - the X25
|
|
; DIAGNOSTIC information will be extracted from the response and sent
|
|
; to the user.
|
|
; ERROR_NO_CARRIER means that the remote modem hung up.
|
|
; ERROR resonses are for generic failures.
|