Leaked source code of windows server 2003
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

939 lines
38 KiB

RFC1230-MIB DEFINITIONS ::= BEGIN
-- IEEE 802.4 Token Bus MIB
IMPORTS
experimental
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212;
-- This MIB Module uses the extended OBJECT-TYPE macro as
-- defined in [9].
dot4 OBJECT IDENTIFIER ::= { experimental 7 }
-- All representations of MAC addresses in this MIB Module
-- use, as a textual convention (i.e. this convention does
-- not affect their encoding), the data type:
MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet
-- address in the
-- "canonical" order
-- defined by IEEE
-- 802.1a.
-- 16-bit addresses, if needed, are represented by setting
-- their upper 4 octets to all 0's, i.e., AAFF would be
-- represented as 00000000AAFF.
-- This specification follows the 802.4 convention of
-- specifying time intervals, which are dependent on the
-- bandwidth of the media, in units of octet time. One
-- octet time is the time taken to transmit eight bits.
-- Representation of such time intervals in this MIB Module
-- use, as a textual convention (i.e., this convention does
-- not affect their encoding), the data type:
OctetTime ::= INTEGER -- the value of a time
-- interval in units of octet
-- time.
-- The 802.4 Operational Table
-- This table contains state and parameter information which
-- is specific to 802.4 interfaces. It is mandatory that
-- systems having 802.4 interfaces implement this table in
-- addition to the generic interfaces table [4,6] and its
-- generic extensions [11].
dot4Table OBJECT-TYPE
SYNTAX SEQUENCE OF Dot4Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains Token Bus interface
parameters and state variables, one entry
per 802.5 interface."
::= { dot4 1 }
dot4Entry OBJECT-TYPE
SYNTAX Dot4Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Token Bus status and operational
parameter values for an 802.4 interface."
INDEX { dot4IfIndex }
::= { dot4Table 1 }
Dot4Entry ::= SEQUENCE {
dot4IfIndex
INTEGER,
dot4Options
INTEGER,
dot4State
INTEGER,
dot4Commands
INTEGER,
dot4MacAddrLen
INTEGER,
dot4NextStation
MacAddress,
dot4PreviousStation
MacAddress,
dot4SlotTime
OctetTime,
dot4LastTokenRotTime
OctetTime,
dot4HiPriTokenHoldTime
OctetTime,
dot4TargetRotTimeClass4
OctetTime,
dot4TargetRotTimeClass2
OctetTime,
dot4TargetRotTimeClass0
OctetTime,
dot4TargetRotTimeRingMaint
OctetTime,
dot4RingMaintTimerInitValue
OctetTime,
dot4MaxInterSolicitCount
INTEGER (16..255),
dot4MaxRetries
INTEGER (0..7),
dot4MinPostSilencePreambLen
INTEGER,
dot4StandardRevision
INTEGER
}
dot4IfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
802.4 interface for which this entry
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6], for the
same interface."
::= { dot4Entry 1 }
dot4Options OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The optional parts of the 802.4
specification which are in use by this
station. The options of the 802.4
specification are represented by the
following values:
1 - Priority
2 - Request-With-Response
The value of this object is given by the
sum of the above representations for
those options in use on this interface.
The value zero indicates that no options
are in use."
::= { dot4Entry 2 }
dot4State OBJECT-TYPE
SYNTAX INTEGER {
other(1),
offline(2),
outOfRing(3),
enteringRing(4),
inRing(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current state of the 802.4
interface. The value of other(1) is
used if the state is unknown
(e.g., due to an error condition)."
::= { dot4Entry 3 }
dot4Commands OBJECT-TYPE
SYNTAX INTEGER {
no-op(1),
enterRing(2),
exitRing(3),
reset(4),
initialize(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object causes the station
to change the state of the interface as
indicated by the specified value. An
initialize(5) command causes the
interfaceto load its operational
parameters from its initialization
parameters; the value of
dot4InitInRingDesired determines
whether the station tries to enter the
logical ring immediately.
Note that the 802.4 specification
suggests a station remain Offline after a
'remote Network Management' reset(4),
until a 'local Network Management'
initialize(5) is performed.
Setting this object to a value of
no-op(1) has no effect. When read,
this object always has the value no-op(1)."
::= { dot4Entry 4 }
dot4MacAddrLen OBJECT-TYPE
SYNTAX INTEGER {
sixteenBit(1),
forty-eightBit(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the size of MAC
addresses interpreted by this station."
::= { dot4Entry 5 }
dot4NextStation OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address of this station's
successor in the logical ring."
::= { dot4Entry 6 }
dot4PreviousStation OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source MAC address of the last token
addressed to this station."
::= { dot4Entry 7 }
dot4SlotTime OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum time any station need wait
for an immediate MAC-level response from
another station.
This value must the same in all stations on
the 802.4 network."
::= { dot4Entry 8 }
dot4LastTokenRotTime OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The observed token rotation time for the
last token rotation, timed from token
arrival to token arrival. A value of
zero indicates that the token is not
rotating."
::= { dot4Entry 9 }
dot4HiPriTokenHoldTime OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum duration for which a station
can hold the token to transmit frames of
access class 6 (if the priority option is
implemented), or of any access class (if
the priority option is not implemented)."
::= { dot4Entry 10 }
dot4TargetRotTimeClass4 OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If the priority scheme is being used,
this value specifies a limit on how long
a station can transmit frames at access
class 4. The limit is measured from the
time the station is able to start
transmitting frames at this access class
on one rotation, to the time it must stop
transmitting frames at this access class
on the next rotation. If the priority
scheme is not being used, this object has
the value 0."
::= { dot4Entry 11 }
dot4TargetRotTimeClass2 OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If the priority scheme is being used,
this value specifies a limit on how long
a station can transmit frames at access
class 2. The limit is measured from the
time the station is able to start
transmitting frames at this access
class on one rotation, to the time it
must stop transmitting frames at this
access class on the next rotation. If
the priority scheme is not being used,
this object has the value 0."
::= { dot4Entry 12 }
dot4TargetRotTimeClass0 OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If the priority scheme is being used,
this value specifies a limit on how long
a station can transmit frames at access
class 0. The limit is measured from the
time the station is able to start
transmitting frames at this access
class on one rotation, to the time it
must stop transmitting frames at this
access class on the next rotation. If
the priority scheme is not being used,
this object has the value 0."
::= { dot4Entry 13 }
dot4TargetRotTimeRingMaint OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value used to limit the duration of a
token rotation. If the duration of a
token rotation exceeds this value, the
station will not open the response window
to solicit for a new successor."
::= { dot4Entry 14 }
dot4RingMaintTimerInitValue OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value to which the
dot4TargetRotTimeRingMaint is set, each
time the station enters the ring.
A large value will cause the station to
solicit successors immediately upon entry
to the ring; a value of zero will cause
the station to defer this solicitation
for at least one token rotation."
::= { dot4Entry 15 }
dot4MaxInterSolicitCount OBJECT-TYPE
SYNTAX INTEGER (16..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of consecutive token
rotations without soliciting for a
successor. If this count expires, the
station opens the response window to
solicit for a successor (providing the
duration of the current token rotation
has not exceeded
dot4TargetRotTimeRingMaint). The least
significant two bits of the count are
determined randomly by the station on a
per-use basis."
::= { dot4Entry 16 }
dot4MaxRetries OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of retries of a
Request-with-Response (RWR) frame. If
the RWR option is not in use, this object
has the value 0."
::= { dot4Entry 17 }
dot4MinPostSilencePreambLen OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum number of octets of preamble
on the first frame transmitted by this
station after a period of 'transmitted'
silence."
::= { dot4Entry 18 }
dot4StandardRevision OBJECT-TYPE
SYNTAX INTEGER {
rev2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Revision number of the 802.4 standard
implemented by this station."
::= { dot4Entry 19 }
-- 802.4 Initialization Table
-- This table contains the parameter information used by an
-- 802.4 interface as the values to be assigned to its
-- operational parameters upon initialization. It is
-- mandatory that systems having 802.4 interfaces implement
-- this table.
dot4InitTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot4InitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains Token Bus
initialization parameters, one entry per
802.4 interface."
::= { dot4 2 }
dot4InitEntry OBJECT-TYPE
SYNTAX Dot4InitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Token Bus initialization
parameters for an 802.4 interface."
INDEX { dot4InitIfIndex }
::= { dot4InitTable 1 }
Dot4InitEntry ::= SEQUENCE {
dot4InitIfIndex
INTEGER,
dot4InitSlotTime
OctetTime,
dot4InitMaxInterSolicitCount
INTEGER (16..255),
dot4InitMaxRetries
INTEGER (0..7),
dot4InitHiPriTokenHoldTime
OctetTime,
dot4InitTargetRotTimeClass4
OctetTime,
dot4InitTargetRotTimeClass2
OctetTime,
dot4InitTargetRotTimeClass0
OctetTime,
dot4InitTargetRotTimeRingMaint
OctetTime,
dot4InitRingMaintTimerInitValue
OctetTime,
dot4InitMinPostSilencePreambLen
INTEGER,
dot4InitInRingDesired
INTEGER
}
dot4InitIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
802.4 interface for which this entry
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6], for
the same interface."
::= { dot4InitEntry 1 }
dot4InitSlotTime OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4SlotTime when the station is
initialized."
::= { dot4InitEntry 2 }
dot4InitMaxInterSolicitCount OBJECT-TYPE
SYNTAX INTEGER (16..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4MaxInterSolicitCount when the station
is initialized."
::= { dot4InitEntry 3 }
dot4InitMaxRetries OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4MaxRetries when the station is
initialized."
::= { dot4InitEntry 4 }
dot4InitHiPriTokenHoldTime OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4HiPriTokenHoldTime when the station
is initialized."
::= { dot4InitEntry 5 }
dot4InitTargetRotTimeClass4 OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4TargetRotTimeClass4 when the station
is initialized."
::= { dot4InitEntry 6 }
dot4InitTargetRotTimeClass2 OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4TargetRotTimeClass2 when the station
is initialized."
::= { dot4InitEntry 7 }
dot4InitTargetRotTimeClass0 OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4TargetRotTimeClass0 when the station
is initialized."
::= { dot4InitEntry 8 }
dot4InitTargetRotTimeRingMaint OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4TargetRotTimeRingMaint when the station
is initialized."
::= { dot4InitEntry 9 }
dot4InitRingMaintTimerInitValue OBJECT-TYPE
SYNTAX OctetTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4RingMaintTimerInitValue when the
station is initialized."
::= { dot4InitEntry 10 }
dot4InitMinPostSilencePreambLen OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value assigned to the object
dot4MinPostSilencePreambLen when the
station is initialized."
::= { dot4InitEntry 11 }
dot4InitInRingDesired OBJECT-TYPE
SYNTAX INTEGER {
inRing(1),
outOfRing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object determines whether the
station will attempt to enter the logical
ring immediately after initialization."
::= { dot4InitEntry 12 }
-- 802.4 Statistics Table
-- This table contains Token Bus statistics, one entry per
-- 802.4 interface. It is mandatory that systems having
-- 802.4 interfaces implement this table.
dot4StatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot4StatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing Token Bus statistics.
All the statistics are defined using the
syntax Counter as 32 bit wrap around
counters. Thus, if an interface's
hardware chip set maintains these
statistics in 16-bit counters, then the
agent must read the hardware's counters
frequently enough to prevent loss of
significance, in order to maintain
a 32-bit counter in software."
::= { dot4 3 }
dot4StatsEntry OBJECT-TYPE
SYNTAX Dot4StatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing the 802.4 statistics
for a particular interface."
INDEX { dot4StatsIfIndex }
::= { dot4StatsTable 1 }
Dot4StatsEntry ::= SEQUENCE {
dot4StatsIfIndex
INTEGER,
dot4StatsTokenPasses
Counter,
dot4StatsTokenHeards
Counter,
dot4StatsNoSuccessors
Counter,
dot4StatsWhoFollows
Counter,
dot4StatsTokenPassFails
Counter,
dot4StatsNonSilences
Counter,
dot4StatsFcsErrors
Counter,
dot4StatsEbitErrors
Counter,
dot4StatsFrameFrags
Counter,
dot4StatsFrameTooLongs
Counter,
dot4StatsOverRuns
Counter,
dot4StatsDupAddresses
Counter
}
dot4StatsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
802.4 interface for which this entry
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6], for the
same interface."
::= { dot4StatsEntry 1 }
dot4StatsTokenPasses OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of times this station has
passed the token."
::= { dot4StatsEntry 2 }
dot4StatsTokenHeards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of tokens heard by this
station."
::= { dot4StatsEntry 3 }
dot4StatsNoSuccessors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the station could
not find a successor while believing
itself not the only station in the ring.
This can signify a faulty transmitter
condition in this station."
::= { dot4StatsEntry 4 }
dot4StatsWhoFollows OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the station has had
to look for a new next station."
::= { dot4StatsEntry 5 }
dot4StatsTokenPassFails OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the station failed in
passing the token to the next station."
::= { dot4StatsEntry 6 }
dot4StatsNonSilences OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of occurrences of non-silence
followed by silence in which a start
delimiter was not detected."
::= { dot4StatsEntry 7 }
dot4StatsFcsErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames received with an
incorrect FCS and the E-bit reset."
::= { dot4StatsEntry 8 }
dot4StatsEbitErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames the station
received with the E-bit set in the
end delimiter."
::= { dot4StatsEntry 9 }
dot4StatsFrameFrags OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of occurrences of receiving a
start delimiter followed by another start
delimiter, an invalid symbol sequence or
silence, without an intervening end
delimiter."
::= { dot4StatsEntry 10 }
dot4StatsFrameTooLongs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that were received
that were larger than the media's MTU."
::= { dot4StatsEntry 11 }
dot4StatsOverRuns OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times a FIFO overrun was
detected in the station."
::= { dot4StatsEntry 12 }
dot4StatsDupAddresses OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times this station
detected another station using the same
MAC address."
::= { dot4StatsEntry 13 }
-- 802.4 Interface Tests
dot4Tests OBJECT IDENTIFIER ::= { dot4 5 }
-- The extensions to the interfaces table proposed in [11]
-- define a table object, ifExtnsTestTable, through which a
-- network manager can instruct an agent to test an interface
-- for various faults. A test to be performed is identified
-- (as the value of ifExtnsTestType) via an OBJECT IDENTIFIER.
-- When a test fails, the object ifExtnsTestCode, defined in
-- [11], may contain a media-specific error-code. For 802.4
-- interfaces, the following is defined as the value of
-- ifExtnsTestCode when a test fails because the modem could
-- not be initialized:
dot4Errors OBJECT IDENTIFIER ::= { dot4 4 }
dot4ModemInitFailed OBJECT IDENTIFIER ::= { dot4Errors 1 }
-- The Full-Duplex Loop Back Test is a common test, defined
-- in [11] as:
--
-- testFullDuplexLoopBack
--
-- Invoking this test on a 802.4 interface causes the
-- interface to check the path from memory through the chip
-- set's serial interface back to memory, thus checking the
-- proper functioning of the transmit and receive machines
-- of the token bus hardware.
-- This test may only be invoked when the interface is
-- the Offline state.
-- The FIFO Path test is defined by:
testFifoPath OBJECT IDENTIFIER ::= { dot4Tests 1 }
-- Invoking this test causes the interface to check the path
-- from memory to the chip set's FIFO and back to memory.
-- This test checks the hosts interface to the token bus
-- hardware. This test may only be invoked when the
-- interface is the Offline state.
-- The External Loopback test is defined by:
testExternalLoopback OBJECT IDENTIFIER ::= { dot4Tests 2 }
-- Invoking this test causes the interface to check the path
-- from memory through the chip set and out onto the network
-- for external (e.g., at the head-end) loopback through the
-- chip set to memory. This test checks the host's interface
-- to the 802.4 network. This test is liable to cause
-- serious disruption if invoked on an operational network.
-- 802.4 Hardware Chip Sets
dot4ChipSets OBJECT IDENTIFIER ::= { dot4 6 }
-- The extensions to the interfaces table proposed in [11]
-- define an object, ifExtnsChipSet, with the syntax of
-- OBJECT IDENTIFIER, to identify the hardware chip set in
-- use by an interface. That definition specifies just
-- one applicable object identifier:
--
-- unknownChipSet
--
-- for use as the value of ifExtnsChipSet when the specific
-- chip set is unknown.
--
-- This MIB defines the following for use as values of
-- ifExtnsChipSet:
-- for use as values of ifExtnsChipSet
-- Motorola 68824 Token Bus Controller
chipSetMc68824 OBJECT IDENTIFIER ::= { dot4ChipSets 1 }
END