Leaked source code of windows server 2003
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

117 lines
3.3 KiB

PAGE,132
;***************************************************************************
;*
;* DLLENTRY.ASM
;*
;* TOOLHELP.DLL Entry code
;*
;* This module generates a code segment called INIT_TEXT.
;* It initializes the local heap if one exists and then calls
;* the C routine LibMain() which should have the form:
;* BOOL FAR PASCAL LibMain(HANDLE hInstance,
;* WORD wDataSeg,
;* WORD cbHeap,
;* LPSTR lpszCmdLine);
;*
;* The result of the call to LibMain is returned to Windows.
;* The C routine should return TRUE if it completes initialization
;* successfully, FALSE if some error occurs.
;*
;**************************************************************************
INCLUDE TOOLPRIV.INC
extrn LocalInit:FAR
extrn GlobalUnwire:FAR
sBegin CODE
assumes CS,CODE
externNP ToolHelpLibMain
externNP HelperReleaseSelector
externNP NotifyUnInit
externNP InterruptUnInit
?PLM=0
externA <_acrtused> ;Ensures that Win DLL startup code is linked
?PLM=1
; LibEntry
;
; KERNEL calls this when the TOOLHELP is loaded the first time
cProc LibEntry, <PUBLIC,FAR>
cBegin
push di ;Handle of the module instance
push ds ;Library data segment
push cx ;Heap size
push es ;Command line segment
push si ;Command line offset
;** If we have some heap then initialize it
jcxz callc ;Jump if no heap specified
;** Call the Windows function LocalInit() to set up the heap
;** LocalInit((LPSTR)start, WORD cbHeap);
xor ax,ax
cCall LocalInit <ds, ax, cx>
or ax,ax ;Did it do it ok ?
jz error ;Quit if it failed
;** Invoke our initialization routine
callc:
call ToolHelpLibMain ;Invoke the 'C' routine (result in AX)
jmp SHORT exit
error:
pop si ;Clean up stack on a LocalInit error
pop es
pop cx
pop ds
pop di
exit:
cEnd
; WEP
; Windows Exit Procedure
cProc WEP, <FAR,PUBLIC>, <si,di,ds>
parmW wState
cBegin
;** Make sure our DS is safe
mov ax,_DATA ;Get the DS value
lar cx,ax ;Is it OK?
jz @F
jmp SHORT WEP_Bad ;No
@@: and cx,8a00h ;Clear all but P, Code/Data, R/W bits
cmp cx,8200h ;Is it P, R/W, Code/Data?
jne WEP_Bad ;No
mov ax,_DATA ;Get our DS now
mov ds,ax
;** Uninstall the Register PTrace notifications if necessary
cmp wNotifyInstalled,0
jz @F
cCall NotifyUnInit
@@:
;** Release fault handlers
cmp wIntInstalled,0
jz @F
cCall InterruptUnInit
@@:
;** Release our roving selector
test wTHFlags, TH_WIN30STDMODE
jz @F
cCall HelperReleaseSelector, <wSel>
@@:
WEP_Bad:
mov ax,1
cEnd
sEnd
END LibEntry