You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
171 lines
5.5 KiB
171 lines
5.5 KiB
;/*++ BUILD Version: 0001 // Increment this if a change has global effects
|
|
;
|
|
;Copyright (c) 1992, 1993 Microsoft Corporation
|
|
;
|
|
;Module Name:
|
|
;
|
|
; sermlog.mc
|
|
;
|
|
;Abstract:
|
|
;
|
|
; Constant definitions for the I/O error code log values.
|
|
;
|
|
;Revision History:
|
|
;
|
|
;--*/
|
|
;
|
|
;#ifndef _SERMLOG_
|
|
;#define _SERMLOG_
|
|
;
|
|
;//
|
|
;// Status values are 32 bit values layed out as follows:
|
|
;//
|
|
;// 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
|
|
;// 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
|
|
;// +---+-+-------------------------+-------------------------------+
|
|
;// |Sev|C| Facility | Code |
|
|
;// +---+-+-------------------------+-------------------------------+
|
|
;//
|
|
;// where
|
|
;//
|
|
;// Sev - is the severity code
|
|
;//
|
|
;// 00 - Success
|
|
;// 01 - Informational
|
|
;// 10 - Warning
|
|
;// 11 - Error
|
|
;//
|
|
;// C - is the Customer code flag
|
|
;//
|
|
;// Facility - is the facility code
|
|
;//
|
|
;// Code - is the facility's status code
|
|
;//
|
|
;
|
|
MessageIdTypedef=NTSTATUS
|
|
|
|
SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS
|
|
Informational=0x1:STATUS_SEVERITY_INFORMATIONAL
|
|
Warning=0x2:STATUS_SEVERITY_WARNING
|
|
Error=0x3:STATUS_SEVERITY_ERROR
|
|
)
|
|
|
|
FacilityNames=(System=0x0
|
|
RpcRuntime=0x2:FACILITY_RPC_RUNTIME
|
|
RpcStubs=0x3:FACILITY_RPC_STUBS
|
|
Io=0x4:FACILITY_IO_ERROR_CODE
|
|
Sermouse=0x5:FACILITY_SERMOUSE_ERROR_CODE
|
|
)
|
|
|
|
|
|
|
|
MessageId=0x0001 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_INSUFFICIENT_RESOURCES
|
|
Language=English
|
|
Not enough memory was available to allocate internal storage needed for the device %1.
|
|
.
|
|
|
|
MessageId=0x0002 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_NO_BUFFER_ALLOCATED
|
|
Language=English
|
|
Not enough memory was available to allocate the ring buffer that holds incoming data for %1.
|
|
.
|
|
|
|
MessageId=0x0003 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_REGISTERS_NOT_MAPPED
|
|
Language=English
|
|
The hardware locations for %1 could not be translated to something the memory management system understands.
|
|
.
|
|
|
|
MessageId=0x0004 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_RESOURCE_CONFLICT
|
|
Language=English
|
|
The hardware resources for %1 are already in use by another device.
|
|
.
|
|
|
|
MessageId=0x0005 Facility=Sermouse Severity=Informational SymbolicName=SERMOUSE_NOT_ENOUGH_CONFIG_INFO
|
|
Language=English
|
|
Some firmware configuration information was incomplete, so defaults were used.
|
|
.
|
|
|
|
MessageId=0x0006 Facility=Sermouse Severity=Informational SymbolicName=SERMOUSE_USER_OVERRIDE
|
|
Language=English
|
|
User configuration data is overriding firmware configuration data.
|
|
.
|
|
|
|
MessageId=0x0007 Facility=Sermouse Severity=Warning SymbolicName=SERMOUSE_NO_DEVICEMAP_CREATED
|
|
Language=English
|
|
Unable to create the device map entry for %1.
|
|
.
|
|
|
|
MessageId=0x0008 Facility=Sermouse Severity=Warning SymbolicName=SERMOUSE_NO_DEVICEMAP_DELETED
|
|
Language=English
|
|
Unable to delete the device map entry for %1.
|
|
.
|
|
|
|
MessageId=0x0009 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_NO_INTERRUPT_CONNECTED
|
|
Language=English
|
|
Could not connect the interrupt for %1.
|
|
.
|
|
|
|
MessageId=0x000A Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_INVALID_ISR_STATE
|
|
Language=English
|
|
The ISR has detected an internal state error in the driver for %1.
|
|
.
|
|
|
|
MessageId=0x000C Facility=Sermouse Severity=Informational SymbolicName=SERMOUSE_MOU_BUFFER_OVERFLOW
|
|
Language=English
|
|
The ring buffer that stores incoming mouse data has overflowed (buffer size is configurable via the registry).
|
|
.
|
|
|
|
MessageId=0x000D Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_INVALID_STARTIO_REQUEST
|
|
Language=English
|
|
The Start I/O procedure has detected an internal error in the driver for %1.
|
|
.
|
|
|
|
MessageId=0x000E Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_INVALID_INITIATE_STATE
|
|
Language=English
|
|
The Initiate I/O procedure has detected an internal state error in the driver for %1.
|
|
.
|
|
|
|
MessageId=0x0010 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_MOU_RESET_COMMAND_FAILED
|
|
Language=English
|
|
The mouse reset failed.
|
|
.
|
|
|
|
MessageId=0x0012 Facility=Sermouse Severity=Warning SymbolicName=SERMOUSE_MOU_RESET_RESPONSE_FAILED
|
|
Language=English
|
|
The device sent an incorrect response(s) following a mouse reset.
|
|
.
|
|
|
|
MessageId=0x0016 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_SET_SAMPLE_RATE_FAILED
|
|
Language=English
|
|
Could not set the mouse sample rate.
|
|
.
|
|
|
|
MessageId=0x0017 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_SET_RESOLUTION_FAILED
|
|
Language=English
|
|
Could not set the mouse resolution.
|
|
.
|
|
|
|
MessageId=0x0018 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_MOU_ENABLE_XMIT
|
|
Language=English
|
|
Could not enable transmissions from the mouse.
|
|
.
|
|
|
|
MessageId=0x0019 Facility=Sermouse Severity=Warning SymbolicName=SERMOUSE_NO_SYMLINK_CREATED
|
|
Language=English
|
|
Unable to create the symbolic link for %1.
|
|
.
|
|
|
|
MessageId=0x001A Facility=Sermouse Severity=Warning SymbolicName=SERMOUSE_NO_SUCH_DEVICE
|
|
Language=English
|
|
The serial mouse does not exist or was not detected.
|
|
.
|
|
|
|
MessageId=0x001b Facility=Sermouse Severity=Informational SymbolicName=SERMOUSE_NOT_DETECTABLE
|
|
Language=English
|
|
Cannot detect surprise removal of the mouse on %1.
|
|
.
|
|
|
|
MessageId=0x001c Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_ATTACH_DEVICE_FAILED
|
|
Language=English
|
|
Could not attach to the PnP device stack.
|
|
.
|
|
;#endif /* _SERMLOG_ */
|