// File:
|
|
|
|
//
|
|
|
|
// Module: MS SNMP Provider
|
|
|
|
//
|
|
|
|
// Purpose:
|
|
|
|
//
|
|
|
|
// Copyright (c) 1997-2001 Microsoft Corporation, All Rights Reserved
|
|
//
|
|
//***************************************************************************
|
|
|
|
#include "precomp.h"
|
|
#include <provexpt.h>
|
|
#include <snmptempl.h>
|
|
#include <snmpmt.h>
|
|
#include <typeinfo.h>
|
|
#include <process.h>
|
|
#include <objbase.h>
|
|
#include <stdio.h>
|
|
#include <wbemidl.h>
|
|
#include <snmplog.h>
|
|
#include <snmpcl.h>
|
|
#include <snmpcont.h>
|
|
#include <snmptype.h>
|
|
#include <snmpauto.h>
|
|
#include <snmpevt.h>
|
|
#include <snmpthrd.h>
|
|
#include <snmpobj.h>
|
|
|
|
#include <smir.h>
|
|
#include <notify.h>
|
|
|
|
#include <evtdefs.h>
|
|
#include <evtthrd.h>
|
|
#include <evtmap.h>
|
|
#include <evtprov.h>
|
|
#include <evtreft.h>
|
|
|
|
extern CEventProviderWorkerThread* g_pWorkerThread ;
|
|
|
|
CReferentMapper::CReferentMapper()
|
|
{
|
|
}
|
|
|
|
|
|
CReferentMapper::~CReferentMapper()
|
|
{
|
|
}
|
|
|
|
HRESULT CReferentMapper::GetTypeAndIndexQuals(const wchar_t* prop, CIMTypeStruct& type, ULONG& index)
|
|
{
|
|
IWbemClassObject* propObj = NULL;
|
|
GetClassInstance(&propObj);
|
|
|
|
if (NULL == propObj)
|
|
{
|
|
return WBEM_E_FAILED;
|
|
}
|
|
|
|
IWbemQualifierSet* pQuals = NULL;
|
|
HRESULT result = propObj->GetPropertyQualifierSet((wchar_t*)prop, &pQuals);
|
|
|
|
if (FAILED(result))
|
|
{
|
|
return result;
|
|
}
|
|
|
|
VARIANT v;
|
|
result = pQuals->Get(EVENT_VBINDEX_QUAL, 0, &v, NULL);
|
|
|
|
if (FAILED(result))
|
|
{
|
|
pQuals->Release();
|
|
return result;
|
|
}
|
|
|
|
if (VT_I4 != v.vt)
|
|
{
|
|
VariantClear(&v);
|
|
return WBEM_E_FAILED;
|
|
}
|
|
|
|
index = v.lVal;
|
|
VariantClear(&v);
|
|
result = pQuals->Get(EVENT_CIMTYPE_QUAL, 0, &v, NULL);
|
|
pQuals->Release();
|
|
|
|
if (FAILED(result))
|
|
{
|
|
return result;
|
|
}
|
|
|
|
if (VT_BSTR != v.vt)
|
|
{
|
|
VariantClear(&v);
|
|
return WBEM_E_FAILED;
|
|
}
|
|
|
|
#ifdef WHITESPACE_IN_CIMTYPE
|
|
//Get rid of whitespace...
|
|
CString cimtype;
|
|
wchar_t* tmp = wcstok(v.bstrVal, WHITE_SPACE_CHARS);
|
|
|
|
while (NULL != tmp)
|
|
{
|
|
cimtype += tmp;
|
|
tmp = wcstok(NULL, WHITE_SPACE_CHARS);
|
|
}
|
|
#else //WHITESPACE_IN_CIMTYPE
|
|
CString cimtype = v.bstrVal;
|
|
#endif //WHITESPACE_IN_CIMTYPE
|
|
|
|
VariantClear(&v);
|
|
|
|
//determine if we're an object. If so get the classname...
|
|
CString temp = cimtype.Left(OBJECT_STR_LEN);
|
|
temp.MakeLower();
|
|
|
|
if (temp == OBJECT_STR)
|
|
{
|
|
type.strType = cimtype.Mid(OBJECT_STR_LEN, cimtype.GetLength());
|
|
type.fObject = TRUE;
|
|
}
|
|
else
|
|
{
|
|
type.fObject = FALSE;
|
|
}
|
|
|
|
return WBEM_NO_ERROR;
|
|
}
|
|
|
|
HRESULT CReferentMapper::GetSpecificPropertyValue(long lNumElements, MYWBEM_NAME_ELEMENT *aElements,
|
|
long lFlags, VARIANT *pvValue)
|
|
{
|
|
if ((lNumElements <= 0) || (NULL == aElements) || (NULL == pvValue))
|
|
{
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GetSpecificPropertyValue invalid parms\r\n");
|
|
)
|
|
|
|
return WBEM_E_INVALID_PARAMETER;
|
|
}
|
|
|
|
HRESULT status = WBEM_E_FAILED;
|
|
|
|
//specific properties after first two varbinds
|
|
if ((0 == aElements[0].m_nType) && (m_vbs.length > 2))
|
|
{
|
|
//first check it has the correct VBIndex and CIMType qualifiers...
|
|
CIMTypeStruct proptype;
|
|
ULONG propvbindex;
|
|
|
|
if (FAILED(GetTypeAndIndexQuals(aElements[0].Element.m_wszPropertyName,
|
|
proptype, propvbindex)))
|
|
{
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GetSpecificPropertyValue failed to get index quals\r\n");
|
|
)
|
|
return status;
|
|
}
|
|
|
|
if (propvbindex >= m_vbs.length)
|
|
{
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GetSpecificPropertyValue invalid index return TRUE\r\n");
|
|
)
|
|
return WBEM_NO_ERROR;
|
|
}
|
|
|
|
//we're zero indexed in this world!
|
|
propvbindex--;
|
|
|
|
if (lNumElements == 1)
|
|
{
|
|
if (m_vbs.vbs[propvbindex].fDone)
|
|
{
|
|
//we've done this one already,
|
|
//just get the property value and return it...
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GetSpecificPropertyValue return value\r\n");
|
|
)
|
|
return m_object->Get(aElements[0].Element.m_wszPropertyName, 0, pvValue, 0, 0);
|
|
}
|
|
|
|
if (proptype.fObject)
|
|
{
|
|
//get the embedded class object in full for the property asked for
|
|
IWbemClassObject* pObj = NULL;
|
|
if (SUCCEEDED(CreateEmbeddedProperty(&pObj, propvbindex,
|
|
aElements[0].Element.m_wszPropertyName, proptype.strType)))
|
|
{
|
|
//created the property, set the variant value and return successfully
|
|
//NOTE: as soon as the variant is cleared, the object will be released
|
|
pvValue->vt = VT_UNKNOWN;
|
|
pvValue->punkVal = pObj;
|
|
}
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GetSpecificPropertyValue return value\r\n");
|
|
)
|
|
return WBEM_NO_ERROR;
|
|
}
|
|
else
|
|
{
|
|
//MUST be an embedded property otherwise fail!
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GetSpecificPropertyValue invlaid params\r\n");
|
|
)
|
|
return WBEM_E_FAILED;
|
|
}
|
|
}
|
|
#ifdef FILTERING
|
|
|
|
will not compile as there are still a couple of TO DOs left undone...
|
|
|
|
else if (0 == aElements[1].m_nType)
|
|
{
|
|
if (lNumElements == 2)
|
|
{
|
|
//TO DO:
|
|
//======
|
|
//get a single property value of the embedded object
|
|
}
|
|
else if ((lNumElements == 3) && (1 == aElements[1].m_nType))
|
|
{
|
|
//TO DO:
|
|
//======
|
|
//only if we're an array property of the embedded object
|
|
}
|
|
}
|
|
#endif //FILTERING
|
|
|
|
}
|
|
|
|
return status;
|
|
}
|
|
|
|
|
|
HRESULT CReferentMapper::CreateEmbeddedProperty(IWbemClassObject** ppObj,
|
|
ULONG index,
|
|
const wchar_t* propertyName,
|
|
const wchar_t* className)
|
|
{
|
|
if (NULL == ppObj)
|
|
{
|
|
//invalid out parameter
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::CreateEmbeddedProperty invalid parameter\r\n");
|
|
)
|
|
return WBEM_E_INVALID_PARAMETER;
|
|
}
|
|
|
|
IWbemClassObject* pClass = NULL;
|
|
|
|
//specify no correlation to the class provider
|
|
IWbemContext *pCtx = NULL;
|
|
|
|
HRESULT result = CoCreateInstance(CLSID_WbemContext, NULL,
|
|
CLSCTX_INPROC_SERVER | CLSCTX_LOCAL_SERVER,
|
|
IID_IWbemContext, (void**)&pCtx);
|
|
|
|
if (SUCCEEDED(result))
|
|
{
|
|
VARIANT vCtx;
|
|
VariantInit (&vCtx);
|
|
vCtx.vt = VT_BOOL;
|
|
vCtx.boolVal = VARIANT_FALSE;
|
|
result = pCtx->SetValue(WBEM_CLASS_CORRELATE_CONTEXT_PROP, 0, &vCtx);
|
|
VariantClear(&vCtx);
|
|
|
|
if (FAILED(result))
|
|
{
|
|
pCtx->Release();
|
|
pCtx = NULL;
|
|
}
|
|
}
|
|
else
|
|
{
|
|
pCtx = NULL;
|
|
}
|
|
|
|
BSTR t_className = SysAllocString(className);
|
|
result = m_nspace->GetObject(t_className, pCtx, &pClass);
|
|
SysFreeString(t_className);
|
|
|
|
if (pCtx != NULL)
|
|
{
|
|
pCtx->Release();
|
|
}
|
|
|
|
if (FAILED(result))
|
|
{
|
|
return result;
|
|
}
|
|
|
|
result = pClass->SpawnInstance(0, ppObj);
|
|
|
|
if (FAILED(result))
|
|
{
|
|
pClass->Release();
|
|
return result;
|
|
}
|
|
|
|
//set the varbind as decoded and make sure the notification instance has been created...
|
|
IWbemClassObject* ptmpObj = NULL;
|
|
GetClassInstance(&ptmpObj);
|
|
|
|
if (NULL == m_object)
|
|
{
|
|
pClass->Release();
|
|
return WBEM_E_FAILED;
|
|
}
|
|
|
|
m_vbs.vbs[index].fDone = TRUE;
|
|
WbemSnmpClassObject snmpObj;
|
|
WbemSnmpErrorObject errorObj;
|
|
|
|
if (!snmpObj.Set(errorObj, pClass, FALSE))
|
|
{
|
|
pClass->Release();
|
|
(*ppObj)->Release();
|
|
*ppObj = NULL;
|
|
return WBEM_E_FAILED;
|
|
}
|
|
|
|
snmpObj.SetIsClass(FALSE);
|
|
snmpObj.ResetProperty () ;
|
|
WbemSnmpProperty *snmpProp = snmpObj.NextProperty ();
|
|
|
|
//set all properties to NULL...
|
|
while (snmpProp != NULL)
|
|
{
|
|
snmpProp->SetValue(*ppObj, (SnmpValue*)NULL);
|
|
snmpProp = snmpObj.NextProperty ();
|
|
}
|
|
|
|
snmpProp = snmpObj.FindProperty((wchar_t*)propertyName);
|
|
|
|
if (NULL == snmpProp)
|
|
{
|
|
pClass->Release();
|
|
(*ppObj)->Release();
|
|
*ppObj = NULL;
|
|
return WBEM_E_FAILED;
|
|
}
|
|
|
|
BOOL bSetKeyValue = FALSE;
|
|
|
|
if (!snmpProp->SetValue(&(m_vbs.vbs[index].pVarBind->GetValue())))
|
|
{
|
|
snmpProp->AddQualifier ( WBEM_QUALIFIER_TYPE_MISMATCH ) ;
|
|
WbemSnmpQualifier *qualifier = snmpProp->FindQualifier ( WBEM_QUALIFIER_TYPE_MISMATCH ) ;
|
|
|
|
if ( qualifier )
|
|
{
|
|
VARIANT tmp_V;
|
|
VariantInit(&tmp_V);
|
|
tmp_V.vt = VT_BOOL;
|
|
tmp_V.boolVal = VARIANT_TRUE;
|
|
qualifier->SetValue(tmp_V);
|
|
VariantClear(&tmp_V);
|
|
}
|
|
}
|
|
else
|
|
{
|
|
WbemSnmpQualifier *qualifier = snmpProp->FindQualifier ( WBEM_QUALIFIER_KEY ) ;
|
|
|
|
if ( qualifier )
|
|
{
|
|
VARIANT tmp_V;
|
|
VariantInit(&tmp_V);
|
|
|
|
if (qualifier->GetValue(tmp_V))
|
|
{
|
|
if ((VT_BOOL == tmp_V.vt) && (VARIANT_TRUE == tmp_V.boolVal))
|
|
{
|
|
bSetKeyValue = TRUE;
|
|
}
|
|
}
|
|
|
|
VariantClear(&tmp_V);
|
|
}
|
|
}
|
|
|
|
//have set the property, now set the key properties...
|
|
//first get the instance info...
|
|
const SnmpObjectIdentifier& id = m_vbs.vbs[index].pVarBind->GetInstance();
|
|
IWbemQualifierSet* pQuals = NULL;
|
|
result = pClass->GetPropertyQualifierSet((wchar_t*)propertyName, &pQuals);
|
|
|
|
if (FAILED(result))
|
|
{
|
|
pClass->Release();
|
|
(*ppObj)->Release();
|
|
*ppObj = NULL;
|
|
return WBEM_E_FAILED;
|
|
}
|
|
|
|
VARIANT v;
|
|
result = pQuals->Get(OID_ATTRIBUTE, 0, &v, NULL);
|
|
pQuals->Release();
|
|
|
|
if ((FAILED(result)) || (VT_BSTR != v.vt))
|
|
{
|
|
pClass->Release();
|
|
VariantClear(&v);
|
|
(*ppObj)->Release();
|
|
*ppObj = NULL;
|
|
return WBEM_E_FAILED;
|
|
}
|
|
|
|
SnmpObjectIdentifierType propoidtype(v.bstrVal);
|
|
VariantClear(&v);
|
|
|
|
if (!propoidtype.IsValid())
|
|
{
|
|
pClass->Release();
|
|
(*ppObj)->Release();
|
|
*ppObj = NULL;
|
|
return WBEM_E_FAILED;
|
|
}
|
|
|
|
SnmpObjectIdentifier propoid(propoidtype.GetValue(), propoidtype.GetValueLength());
|
|
SnmpObjectIdentifier* prefix = id.Cut(propoid);
|
|
BOOL fsuccess = FALSE;
|
|
SnmpObjectIdentifier* instinfo = new SnmpObjectIdentifier ( NULL , 0 ) ;
|
|
|
|
if ((prefix != NULL) && (*prefix == propoid))
|
|
{
|
|
fsuccess = id.Suffix(propoid.GetValueLength(),*instinfo);
|
|
|
|
if (instinfo->GetValue() == NULL)
|
|
{
|
|
fsuccess = FALSE;
|
|
snmpProp->AddQualifier ( WBEM_QUALIFIER_TYPE_MISMATCH ) ;
|
|
WbemSnmpQualifier *qualifier = snmpProp->FindQualifier ( WBEM_QUALIFIER_TYPE_MISMATCH ) ;
|
|
|
|
if ( qualifier )
|
|
{
|
|
VARIANT tmp_V;
|
|
VariantInit(&tmp_V);
|
|
tmp_V.vt = VT_BOOL;
|
|
tmp_V.boolVal = VARIANT_TRUE;
|
|
qualifier->SetValue(tmp_V);
|
|
VariantClear(&tmp_V);
|
|
}
|
|
}
|
|
}
|
|
|
|
if (prefix != NULL)
|
|
{
|
|
delete prefix;
|
|
}
|
|
|
|
if ( fsuccess )
|
|
{
|
|
if (snmpObj.IsKeyed())
|
|
{
|
|
snmpObj.ResetKeyProperty() ;
|
|
|
|
while ( fsuccess && (snmpProp = snmpObj.NextKeyProperty()) )
|
|
{
|
|
//set all the key properties using the instance info...
|
|
SnmpInstanceType *decodeValue = snmpProp->GetValue()->Copy();
|
|
SnmpObjectIdentifier t_DecodedValue = decodeValue->Decode(*instinfo) ;
|
|
SnmpObjectIdentifier *decodedObject = new SnmpObjectIdentifier( t_DecodedValue ) ;
|
|
|
|
if (*decodeValue)
|
|
{
|
|
if (!snmpProp->SetValue(decodeValue))
|
|
{
|
|
fsuccess = FALSE;
|
|
}
|
|
}
|
|
else
|
|
{
|
|
fsuccess = FALSE;
|
|
}
|
|
|
|
delete decodeValue ;
|
|
delete instinfo ;
|
|
instinfo = decodedObject ;
|
|
snmpProp = snmpObj.NextKeyProperty();
|
|
}
|
|
|
|
if (fsuccess && instinfo->GetValueLength())
|
|
{
|
|
//instance info left after keys have been set
|
|
fsuccess = FALSE;
|
|
}
|
|
}
|
|
else
|
|
{
|
|
if ( (0 != *(instinfo->GetValue())) || (1 != instinfo->GetValueLength()) )
|
|
{
|
|
//invalid instance info for scalar...
|
|
fsuccess = FALSE;
|
|
}
|
|
}
|
|
}
|
|
|
|
delete instinfo;
|
|
pClass->Release();
|
|
|
|
if (!fsuccess)
|
|
{
|
|
snmpObj.ResetKeyProperty () ;
|
|
VARIANT tmp_V;
|
|
VariantInit(&tmp_V);
|
|
tmp_V.vt = VT_BOOL;
|
|
tmp_V.boolVal = VARIANT_TRUE;
|
|
|
|
while ( snmpProp = snmpObj.NextKeyProperty () )
|
|
{
|
|
WbemSnmpQualifier *qualifier = NULL ;
|
|
snmpProp->AddQualifier ( WBEM_QUALIFIER_TYPE_MISMATCH ) ;
|
|
|
|
if ( qualifier = snmpProp->FindQualifier ( WBEM_QUALIFIER_TYPE_MISMATCH ) )
|
|
{
|
|
qualifier->SetValue(tmp_V);
|
|
}
|
|
else
|
|
{
|
|
// Problem Here
|
|
}
|
|
}
|
|
|
|
if (snmpProp = snmpObj.FindProperty((wchar_t*)propertyName))
|
|
{
|
|
WbemSnmpQualifier *qualifier = NULL ;
|
|
snmpProp->AddQualifier ( WBEM_QUALIFIER_TYPE_MISMATCH ) ;
|
|
|
|
if ( qualifier = snmpProp->FindQualifier ( WBEM_QUALIFIER_TYPE_MISMATCH ) )
|
|
{
|
|
qualifier->SetValue(tmp_V);
|
|
}
|
|
else
|
|
{
|
|
// Problem Here
|
|
}
|
|
}
|
|
|
|
VariantClear(&tmp_V);
|
|
}
|
|
|
|
//check that setting the key values hasn't altered our value, it may be a key
|
|
if ( bSetKeyValue && (snmpProp = snmpObj.FindProperty((wchar_t*)propertyName)) )
|
|
{
|
|
if (*(snmpProp->GetValue()->GetValueEncoding()) != m_vbs.vbs[index].pVarBind->GetValue())
|
|
{
|
|
//set it back to the varbind value and set the error qualifier on the property
|
|
snmpProp->SetValue(&(m_vbs.vbs[index].pVarBind->GetValue()));
|
|
|
|
WbemSnmpQualifier *qualifier = NULL ;
|
|
snmpProp->AddQualifier ( WBEM_QUALIFIER_VALUE_MISMATCH ) ;
|
|
|
|
if ( qualifier = snmpProp->FindQualifier ( WBEM_QUALIFIER_VALUE_MISMATCH ) )
|
|
{
|
|
VARIANT tmp_V;
|
|
VariantInit(&tmp_V);
|
|
tmp_V.vt = VT_BOOL;
|
|
tmp_V.boolVal = VARIANT_TRUE;
|
|
qualifier->SetValue(tmp_V);
|
|
VariantClear(&tmp_V);
|
|
}
|
|
else
|
|
{
|
|
// Problem Here
|
|
}
|
|
|
|
}
|
|
}
|
|
|
|
//generate class object from snmpObj and return success
|
|
if (snmpObj.Get(errorObj, *ppObj))
|
|
{
|
|
//add the property to the notification object...
|
|
VARIANT vObj;
|
|
vObj.vt = VT_UNKNOWN;
|
|
vObj.punkVal = *ppObj;
|
|
(*ppObj)->AddRef();
|
|
result = m_object->Put((wchar_t*)propertyName, 0, &vObj, 0);
|
|
|
|
if (SUCCEEDED(result))
|
|
{
|
|
VariantClear(&vObj);
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::CreateEmbeddedProperty succeeded\r\n");
|
|
)
|
|
return WBEM_NO_ERROR;
|
|
}
|
|
else
|
|
{
|
|
VariantClear(&vObj);
|
|
(*ppObj)->Release();
|
|
*ppObj = NULL;
|
|
return WBEM_E_FAILED;
|
|
}
|
|
|
|
}
|
|
|
|
return WBEM_E_FAILED;
|
|
}
|
|
|
|
|
|
void CReferentMapper::GenerateInstance(IWbemClassObject** ppInst)
|
|
{
|
|
if (NULL == ppInst)
|
|
{
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GenerateInstance invalid parameter\r\n");
|
|
)
|
|
|
|
//invalid out parameter
|
|
return;
|
|
}
|
|
|
|
//set out parameter to NULL;
|
|
*ppInst = NULL;
|
|
IWbemClassObject *pObj = NULL;
|
|
GetClassInstance(&pObj);
|
|
|
|
if (NULL == pObj)
|
|
{
|
|
//failed to get class instance
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GenerateInstance failed to get class defn\r\n");
|
|
)
|
|
return;
|
|
}
|
|
|
|
//get all the property names and set their values...
|
|
SAFEARRAY* pPropNames;
|
|
HRESULT result = pObj->GetNames(NULL, WBEM_FLAG_NONSYSTEM_ONLY, NULL, &pPropNames);
|
|
|
|
if (FAILED(result))
|
|
{
|
|
//failed to get the property names
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GenerateInstance failed to get property array\r\n");
|
|
)
|
|
return;
|
|
}
|
|
|
|
//time to <insert expletive> around with a safearray...
|
|
//work out the size of the safearray and access the data
|
|
if(SafeArrayGetDim(pPropNames) != 1)
|
|
{
|
|
//wrong dimensions in this array
|
|
SafeArrayDestroy(pPropNames);
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GenerateInstance property array has wrong DIM\r\n");
|
|
)
|
|
return;
|
|
}
|
|
|
|
|
|
LONG arraylen = pPropNames->rgsabound[0].cElements;
|
|
BSTR *pbstr;
|
|
result = SafeArrayAccessData(pPropNames, (void **)&pbstr);
|
|
|
|
if(FAILED(result))
|
|
{
|
|
SafeArrayDestroy(pPropNames);
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GenerateInstance failed to access property array\r\n");
|
|
)
|
|
return;
|
|
}
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GenerateInstance set properties\r\n");
|
|
)
|
|
|
|
BOOL t_bSetProp = FALSE;
|
|
|
|
//iterate through the names and set the properties...
|
|
for (LONG i = 0; i < arraylen; i++)
|
|
{
|
|
VARIANT v;
|
|
MYWBEM_NAME_ELEMENT property_struct;
|
|
property_struct.m_nType = 0; //string value
|
|
property_struct.Element.m_wszPropertyName = pbstr[i];
|
|
result = GetPropertyValue(1, &property_struct, 0, &v);
|
|
|
|
if (FAILED(result))
|
|
{
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GenerateInstance failed to get value for %s\r\n",
|
|
pbstr[i]);
|
|
)
|
|
continue;
|
|
}
|
|
else
|
|
{
|
|
t_bSetProp = TRUE;
|
|
}
|
|
|
|
if ((v.vt != VT_NULL) && (v.vt != VT_EMPTY))
|
|
{
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GenerateInstance setting value for %s\r\n",
|
|
pbstr[i]);
|
|
)
|
|
result = pObj->Put(pbstr[i], 0, &v, 0);
|
|
DebugMacro9(
|
|
if (FAILED(result))
|
|
{
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GenerateInstance failed setting value for %s\r\n",
|
|
pbstr[i]);
|
|
}
|
|
)
|
|
}
|
|
|
|
VariantClear(&v);
|
|
}
|
|
|
|
SafeArrayUnaccessData(pPropNames);
|
|
SafeArrayDestroy(pPropNames);
|
|
|
|
//if a single property has been put send it on....
|
|
if (t_bSetProp)
|
|
{
|
|
pObj->AddRef();
|
|
*ppInst = pObj;
|
|
}
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GenerateInstance finished\r\n");
|
|
)
|
|
}
|
|
|
|
|
|
void CReferentMapper::ResetData()
|
|
{
|
|
//do class specific stuff then call parent class's reset
|
|
|
|
CMapToEvent::ResetData();
|
|
}
|
|
|
|
|
|
BOOL CReferentMapper::GetSpecificClass()
|
|
{
|
|
//Build path of mapper instance...
|
|
CString path(EXTMAPPER_CLASS_PATH_PREFIX);
|
|
path += m_oid;
|
|
path += '\"';
|
|
BSTR pathstr = path.AllocSysString();
|
|
IWbemClassObject *pObj = NULL;
|
|
|
|
HRESULT result = g_pWorkerThread->GetServerWrap ()->GetMapperObject(pathstr, NULL, & pObj );
|
|
|
|
SysFreeString(pathstr);
|
|
|
|
if (result == S_OK)
|
|
{
|
|
VARIANT v;
|
|
VariantInit(&v);
|
|
result = pObj->Get(MAPPER_CLASS_EVENTCLASSPROP, 0, &v, NULL, NULL);
|
|
pObj->Release();
|
|
|
|
if (SUCCEEDED(result) && (VT_BSTR == v.vt))
|
|
{
|
|
m_class = v.bstrVal;
|
|
VariantClear(&v);
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GetSpecificClass got the specific class defn\r\n");
|
|
)
|
|
return TRUE;
|
|
}
|
|
else
|
|
{
|
|
VariantClear(&v);
|
|
}
|
|
}
|
|
DebugMacro9(
|
|
SnmpDebugLog :: s_SnmpDebugLog->WriteFileAndLine (
|
|
__FILE__,__LINE__,
|
|
L"CReferentMapper::GetSpecificClass failed to get specific class defn\r\n");
|
|
)
|
|
return FALSE;
|
|
}
|
|
|
|
|