/* Copyright 1999 American Power Conversion, All Rights Reserved
|
|
*
|
|
* Description:
|
|
* This is the implementation of the policy manager for the native UPS service of Windows 2000.
|
|
*
|
|
* Revision History:
|
|
* dsmith 31Mar1999 Created
|
|
*
|
|
*/
|
|
#include <windows.h>
|
|
#include <lmerr.h>
|
|
|
|
#include "polmgr.h"
|
|
#include "statmach.h"
|
|
#include "driver.h"
|
|
#include "states.h"
|
|
#include "events.h"
|
|
#include "upsreg.h"
|
|
#include "eventlog.h"
|
|
|
|
|
|
|
|
|
|
// Internal Variables
|
|
BOOL theIsInitialized = FALSE;
|
|
BOOL theShutdownPending = FALSE;
|
|
|
|
|
|
/**
|
|
* PolicyManagerInit
|
|
*
|
|
* Description:
|
|
* Initializes the UPS service state machine.
|
|
* exiting.
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* An error code defined in lmerr.h
|
|
*/
|
|
DWORD PolicyManagerInit(){
|
|
DWORD err;
|
|
Initializing_Enter(NO_EVENT);
|
|
err = Initializing_DoWork();
|
|
Initializing_Exit(NO_EVENT);
|
|
if (err == NERR_Success){
|
|
theIsInitialized = TRUE;
|
|
}
|
|
// Log the failure event
|
|
else {
|
|
LogEvent(err, NULL, ERROR_SUCCESS);
|
|
}
|
|
return err;
|
|
}
|
|
|
|
|
|
/**
|
|
* PolicyManagerRun
|
|
*
|
|
* Description:
|
|
* Starts the UPS service state machine and does not return until the service is
|
|
* exiting.
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* None
|
|
*/
|
|
void PolicyManagerRun(){
|
|
if (theIsInitialized){
|
|
RunStateMachine();
|
|
}
|
|
}
|
|
|
|
/**
|
|
* PolicyManagerStop
|
|
*
|
|
* Description:
|
|
* Stops the UPS service state machine if the service is not in the middle of a
|
|
* shutdown sequence.
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* None
|
|
*/
|
|
void PolicyManagerStop(){
|
|
StopStateMachine();
|
|
}
|