I. PURPOSE
|
|
|
|
This document details a simple test plan for the Windows NT INFO Server
|
|
Performance Counters.
|
|
|
|
|
|
II. OVERVIEW
|
|
|
|
The Windows NT INFO Server Performance Counters may be installed from
|
|
\\KAYAK\RESKIT\INFOCTRS. INSTALL.BAT will install the counters, and
|
|
REMOVE.BAT will remove the counters. These .BAT files *MUST* be run
|
|
from the INFOCTRS directory.
|
|
|
|
Running INSTALL.BAT will install the performance counters. These
|
|
counters are used by PERFMON.EXE to monitor the activity of the
|
|
Windows NT INFO Server. The following attributes may be monitored:
|
|
|
|
0. Bytes Sent/sec
|
|
|
|
This is the rate that data bytes are sent by the INFO
|
|
Server.
|
|
|
|
1. Bytes Received/sec
|
|
|
|
This is the rate that data bytes are received by the
|
|
INFO Server.
|
|
|
|
2. Bytes Total/sec
|
|
|
|
This is sum of Bytes Sent/sec and Bytes Received/sec.
|
|
This is the total rate of bytes transferred by the
|
|
INFO Server.
|
|
|
|
3. Files Sent
|
|
|
|
This is the total number of files sent by the INFO
|
|
Server.
|
|
|
|
4. Files Received
|
|
|
|
This is the total number of files received by the
|
|
INFO Server.
|
|
|
|
5. Files Total
|
|
|
|
This is sum of Files Sent and Files Received. This
|
|
is the total number of files transferred by the INFO
|
|
Server.
|
|
|
|
6. Current Anonymous Users
|
|
|
|
This is number of anonymous users currently connected
|
|
to the INFO Server.
|
|
|
|
7. Current NonAnonymous Users
|
|
|
|
This is number of non-anonymous users currently
|
|
connected to the INFO Server.
|
|
|
|
8. Total Anonymous Users
|
|
|
|
This is total number of anonymous users that have
|
|
ever connected to the INFO Server.
|
|
|
|
9. Total NonAnonymous Users
|
|
|
|
This is total number of non-anonymous users that have
|
|
ever connected to the INFO Server.
|
|
|
|
10. Maximum Anonymous Users
|
|
|
|
This is maximum number of anonymous users
|
|
simultaneously connected to the INFO Server.
|
|
|
|
11. Maximum NonAnonymous Users
|
|
|
|
This is maximum number of non-anonymous users
|
|
simultaneously connected to the INFO Server.
|
|
|
|
12. Current Connections
|
|
|
|
This is the current number of connections to the INFO
|
|
Server.
|
|
|
|
13. Maximum Connections
|
|
|
|
This is maximum number of simultaneous connections to
|
|
the INFO Server.
|
|
|
|
14. Connection Attempts
|
|
|
|
This is the number of connection attempts that have
|
|
been made to the INFO Server.
|
|
|
|
15. Logon Attempts
|
|
|
|
This is the number of logon attempts that have been
|
|
made to the INFO Server.
|
|
|
|
|
|
III. TESTING
|
|
|
|
These tests assume the test machine has TCP/IP installed, but
|
|
does *NOT* yet have the INFO Server installed. Also, LODCTR.EXE,
|
|
UNLODCTR.EXE, and REGINI.EXE must be on the path.
|
|
|
|
These tests also assume the user knows how to run PerfMon.
|
|
|
|
|
|
0. Run INSTALL.BAT from some directory other than INFOCTRS
|
|
(i.e. cd to K:\FOO then execute \INFOCTRS\INSTALL). This
|
|
should fail with an appropriate error message (must be
|
|
run from INFOCTRS directory).
|
|
|
|
1. Do the same thing with REMOVE.BAT. This should also fail.
|
|
|
|
2. From the INFOCTRS directory, run REMOVE.BAT. This should
|
|
fail.
|
|
|
|
3. From the INFOCTRS directory, run INSTALL.BAT. This should
|
|
fail with an appropriate error message (INFO Server not
|
|
installed).
|
|
|
|
NOTE: This will succeed on an IDW installation.
|
|
|
|
4. Run NCPA and install the INFO Server. Reboot.
|
|
|
|
5. From the INFOCTRS directory, run REMOVE.BAT. This should
|
|
fail.
|
|
|
|
6. From the INFOCTRS directory, run INSTALL.BAT. This should
|
|
succeed.
|
|
|
|
8. Run PerfMon & verify that the counters are working.
|
|
Select the INFO Server object and the default counter.
|
|
Then connect to the target machine via the INFO client and
|
|
verify the Bytes Total/sec counter is responding.
|
|
|
|
Also, verify that each of the counters listed in section II
|
|
are visible.
|
|
|
|
7. Run INSTALL.BAT again. This should also succeed.
|
|
|
|
9. Run PerfMon again to verify nothing is messed up.
|
|
|
|
10. Run REMOVE.BAT. This should succeed.
|
|
|
|
11. Run PerfMon to verify the INFO Server object is no longer
|
|
displayed in the "objects" combo box.
|
|
|
|
12. Run INSTALL.BAT again. This should succeed.
|
|
|
|
13. Run PerfMon to verify the counters were reinstalled.
|
|
|
|
14. While PerfMon is running, stop the INFO Server with
|
|
either NET.EXE or the Services applet. PerfMon should
|
|
continue chugging along with no INFO activity displayed.
|
|
|
|
There will be no other indication in PerfMon that the
|
|
service has been stopped.
|
|
|
|
15. While PerfMon is still running, restart the service.
|
|
Verify that PerfMon is now displaying service activity
|
|
by connecting to the server with the INFO client.
|
|
|
|
16. While PerfMon is running, run REMOVE.BAT. This should
|
|
succeed.
|
|
|
|
PerfMon will still allow you to add/remove INFO Server
|
|
counters until you exit the PerfMon app.
|
|
|
|
17. Exit & restart PerfMon. The INFO Server counters should
|
|
not be available.
|