package sigtrap;
|
|
|
|
=head1 NAME
|
|
|
|
sigtrap - Perl pragma to enable simple signal handling
|
|
|
|
=cut
|
|
|
|
use Carp;
|
|
|
|
$VERSION = 1.02;
|
|
$Verbose ||= 0;
|
|
|
|
sub import {
|
|
my $pkg = shift;
|
|
my $handler = \&handler_traceback;
|
|
my $saw_sig = 0;
|
|
my $untrapped = 0;
|
|
local $_;
|
|
|
|
Arg_loop:
|
|
while (@_) {
|
|
$_ = shift;
|
|
if (/^[A-Z][A-Z0-9]*$/) {
|
|
$saw_sig++;
|
|
unless ($untrapped and $SIG{$_} and $SIG{$_} ne 'DEFAULT') {
|
|
print "Installing handler $handler for $_\n" if $Verbose;
|
|
$SIG{$_} = $handler;
|
|
}
|
|
}
|
|
elsif ($_ eq 'normal-signals') {
|
|
unshift @_, grep(exists $SIG{$_}, qw(HUP INT PIPE TERM));
|
|
}
|
|
elsif ($_ eq 'error-signals') {
|
|
unshift @_, grep(exists $SIG{$_},
|
|
qw(ABRT BUS EMT FPE ILL QUIT SEGV SYS TRAP));
|
|
}
|
|
elsif ($_ eq 'old-interface-signals') {
|
|
unshift @_,
|
|
grep(exists $SIG{$_},
|
|
qw(ABRT BUS EMT FPE ILL PIPE QUIT SEGV SYS TERM TRAP));
|
|
}
|
|
elsif ($_ eq 'stack-trace') {
|
|
$handler = \&handler_traceback;
|
|
}
|
|
elsif ($_ eq 'die') {
|
|
$handler = \&handler_die;
|
|
}
|
|
elsif ($_ eq 'handler') {
|
|
@_ or croak "No argument specified after 'handler'";
|
|
$handler = shift;
|
|
unless (ref $handler or $handler eq 'IGNORE'
|
|
or $handler eq 'DEFAULT') {
|
|
require Symbol;
|
|
$handler = Symbol::qualify($handler, (caller)[0]);
|
|
}
|
|
}
|
|
elsif ($_ eq 'untrapped') {
|
|
$untrapped = 1;
|
|
}
|
|
elsif ($_ eq 'any') {
|
|
$untrapped = 0;
|
|
}
|
|
elsif ($_ =~ /^\d/) {
|
|
$VERSION >= $_ or croak "sigtrap.pm version $_ required,"
|
|
. " but this is only version $VERSION";
|
|
}
|
|
else {
|
|
croak "Unrecognized argument $_";
|
|
}
|
|
}
|
|
unless ($saw_sig) {
|
|
@_ = qw(old-interface-signals);
|
|
goto Arg_loop;
|
|
}
|
|
}
|
|
|
|
sub handler_die {
|
|
croak "Caught a SIG$_[0]";
|
|
}
|
|
|
|
sub handler_traceback {
|
|
package DB; # To get subroutine args.
|
|
$SIG{'ABRT'} = DEFAULT;
|
|
kill 'ABRT', $$ if $panic++;
|
|
syswrite(STDERR, 'Caught a SIG', 12);
|
|
syswrite(STDERR, $_[0], length($_[0]));
|
|
syswrite(STDERR, ' at ', 4);
|
|
($pack,$file,$line) = caller;
|
|
syswrite(STDERR, $file, length($file));
|
|
syswrite(STDERR, ' line ', 6);
|
|
syswrite(STDERR, $line, length($line));
|
|
syswrite(STDERR, "\n", 1);
|
|
|
|
# Now go for broke.
|
|
for ($i = 1; ($p,$f,$l,$s,$h,$w,$e,$r) = caller($i); $i++) {
|
|
@a = ();
|
|
for $arg (@args) {
|
|
$_ = "$arg";
|
|
s/([\'\\])/\\$1/g;
|
|
s/([^\0]*)/'$1'/
|
|
unless /^(?: -?[\d.]+ | \*[\w:]* )$/x;
|
|
s/([\200-\377])/sprintf("M-%c",ord($1)&0177)/eg;
|
|
s/([\0-\37\177])/sprintf("^%c",ord($1)^64)/eg;
|
|
push(@a, $_);
|
|
}
|
|
$w = $w ? '@ = ' : '$ = ';
|
|
$a = $h ? '(' . join(', ', @a) . ')' : '';
|
|
$e =~ s/\n\s*\;\s*\Z// if $e;
|
|
$e =~ s/[\\\']/\\$1/g if $e;
|
|
if ($r) {
|
|
$s = "require '$e'";
|
|
} elsif (defined $r) {
|
|
$s = "eval '$e'";
|
|
} elsif ($s eq '(eval)') {
|
|
$s = "eval {...}";
|
|
}
|
|
$f = "file `$f'" unless $f eq '-e';
|
|
$mess = "$w$s$a called from $f line $l\n";
|
|
syswrite(STDERR, $mess, length($mess));
|
|
}
|
|
kill 'ABRT', $$;
|
|
}
|
|
|
|
1;
|
|
|
|
__END__
|
|
|
|
=head1 SYNOPSIS
|
|
|
|
use sigtrap;
|
|
use sigtrap qw(stack-trace old-interface-signals); # equivalent
|
|
use sigtrap qw(BUS SEGV PIPE ABRT);
|
|
use sigtrap qw(die INT QUIT);
|
|
use sigtrap qw(die normal-signals);
|
|
use sigtrap qw(die untrapped normal-signals);
|
|
use sigtrap qw(die untrapped normal-signals
|
|
stack-trace any error-signals);
|
|
use sigtrap 'handler' => \&my_handler, 'normal-signals';
|
|
use sigtrap qw(handler my_handler normal-signals
|
|
stack-trace error-signals);
|
|
|
|
=head1 DESCRIPTION
|
|
|
|
The B<sigtrap> pragma is a simple interface to installing signal
|
|
handlers. You can have it install one of two handlers supplied by
|
|
B<sigtrap> itself (one which provides a Perl stack trace and one which
|
|
simply C<die()>s), or alternately you can supply your own handler for it
|
|
to install. It can be told only to install a handler for signals which
|
|
are either untrapped or ignored. It has a couple of lists of signals to
|
|
trap, plus you can supply your own list of signals.
|
|
|
|
The arguments passed to the C<use> statement which invokes B<sigtrap>
|
|
are processed in order. When a signal name or the name of one of
|
|
B<sigtrap>'s signal lists is encountered a handler is immediately
|
|
installed, when an option is encountered it affects subsequently
|
|
installed handlers.
|
|
|
|
=head1 OPTIONS
|
|
|
|
=head2 SIGNAL HANDLERS
|
|
|
|
These options affect which handler will be used for subsequently
|
|
installed signals.
|
|
|
|
=over 4
|
|
|
|
=item B<stack-trace>
|
|
|
|
The handler used for subsequently installed signals outputs a Perl stack
|
|
trace to STDERR and then tries to dump core. This is the default signal
|
|
handler.
|
|
|
|
=item B<die>
|
|
|
|
The handler used for subsequently installed signals calls C<die>
|
|
(actually C<croak>) with a message indicating which signal was caught.
|
|
|
|
=item B<handler> I<your-handler>
|
|
|
|
I<your-handler> will be used as the handler for subsequently installed
|
|
signals. I<your-handler> can be any value which is valid as an
|
|
assignment to an element of C<%SIG>.
|
|
|
|
=back
|
|
|
|
=head2 SIGNAL LISTS
|
|
|
|
B<sigtrap> has a few built-in lists of signals to trap. They are:
|
|
|
|
=over 4
|
|
|
|
=item B<normal-signals>
|
|
|
|
These are the signals which a program might normally expect to encounter
|
|
and which by default cause it to terminate. They are HUP, INT, PIPE and
|
|
TERM.
|
|
|
|
=item B<error-signals>
|
|
|
|
These signals usually indicate a serious problem with the Perl
|
|
interpreter or with your script. They are ABRT, BUS, EMT, FPE, ILL,
|
|
QUIT, SEGV, SYS and TRAP.
|
|
|
|
=item B<old-interface-signals>
|
|
|
|
These are the signals which were trapped by default by the old
|
|
B<sigtrap> interface, they are ABRT, BUS, EMT, FPE, ILL, PIPE, QUIT,
|
|
SEGV, SYS, TERM, and TRAP. If no signals or signals lists are passed to
|
|
B<sigtrap>, this list is used.
|
|
|
|
=back
|
|
|
|
For each of these three lists, the collection of signals set to be
|
|
trapped is checked before trapping; if your architecture does not
|
|
implement a particular signal, it will not be trapped but rather
|
|
silently ignored.
|
|
|
|
=head2 OTHER
|
|
|
|
=over 4
|
|
|
|
=item B<untrapped>
|
|
|
|
This token tells B<sigtrap> to install handlers only for subsequently
|
|
listed signals which aren't already trapped or ignored.
|
|
|
|
=item B<any>
|
|
|
|
This token tells B<sigtrap> to install handlers for all subsequently
|
|
listed signals. This is the default behavior.
|
|
|
|
=item I<signal>
|
|
|
|
Any argument which looks like a signal name (that is,
|
|
C</^[A-Z][A-Z0-9]*$/>) indicates that B<sigtrap> should install a
|
|
handler for that name.
|
|
|
|
=item I<number>
|
|
|
|
Require that at least version I<number> of B<sigtrap> is being used.
|
|
|
|
=back
|
|
|
|
=head1 EXAMPLES
|
|
|
|
Provide a stack trace for the old-interface-signals:
|
|
|
|
use sigtrap;
|
|
|
|
Ditto:
|
|
|
|
use sigtrap qw(stack-trace old-interface-signals);
|
|
|
|
Provide a stack trace on the 4 listed signals only:
|
|
|
|
use sigtrap qw(BUS SEGV PIPE ABRT);
|
|
|
|
Die on INT or QUIT:
|
|
|
|
use sigtrap qw(die INT QUIT);
|
|
|
|
Die on HUP, INT, PIPE or TERM:
|
|
|
|
use sigtrap qw(die normal-signals);
|
|
|
|
Die on HUP, INT, PIPE or TERM, except don't change the behavior for
|
|
signals which are already trapped or ignored:
|
|
|
|
use sigtrap qw(die untrapped normal-signals);
|
|
|
|
Die on receipt one of an of the B<normal-signals> which is currently
|
|
B<untrapped>, provide a stack trace on receipt of B<any> of the
|
|
B<error-signals>:
|
|
|
|
use sigtrap qw(die untrapped normal-signals
|
|
stack-trace any error-signals);
|
|
|
|
Install my_handler() as the handler for the B<normal-signals>:
|
|
|
|
use sigtrap 'handler', \&my_handler, 'normal-signals';
|
|
|
|
Install my_handler() as the handler for the normal-signals, provide a
|
|
Perl stack trace on receipt of one of the error-signals:
|
|
|
|
use sigtrap qw(handler my_handler normal-signals
|
|
stack-trace error-signals);
|
|
|
|
=cut
|