;; Sample INI file for IceCAP 4.3.
;;
;; IceCAP is MICROSOFT CONFIDENTIAL, and should not be distributed except
;; under NDA.
;;
;; To customize your IceCAP runs, copy this file to your working directory
;; or to your Windows directory and make the appropriate changes.
;;
[IceCAP]
;;
;;****************************************************************************
;; The Profile= value is read once for each process that starts. HOWEVER, the
;; Global value (third parameter) is read only ONCE, when the logger starts.
;;****************************************************************************
;;
;;
;; Profile sets the initial profiling state for the Thread, Process, and
;; Global levels.
;; Syntax is: Profile=On|Off[,On|Off,[On|Off|Never]]. Default is On,On,On.
;;
;; IceCAP 3.6 syntax works fine for setting the thread-level default value.
;; Note that we only support Never at the Global level.
;;
; Profile=On
; Profile=Off
;;
;; IceCAP 4.x allows greater flexibility, to control all three levels.
;;
; Profile=On,On,On
; Profile=On,Off,On
; Profile=On,On,Off
; Profile=Off,Off,Never
;;
;;
;;****************************************************************************
;; The following settings are read ONCE when the logger is initializing.
;; These are global settings which are ONLY read from the [IceCAP] section
;; of the INI file. For any of the sample settings below, remove the comment
;; indicator ";" at the beginning of the line to make use of the setting.
;;****************************************************************************
;;
;; DataCompression determines whether or not the logger compresses the
;; collected data. Note that compression takes additional cpu cycles which
;; may effect the performance of the profiled application. Default is None.
;; Note: At this time, Aggressive is the same as Standard.
;;
; DataCompression=None
; DataCompression=Standard
; DataCompression=Aggressive
;;
;;
;; InMemoryCollection determines whether or not to put the IceCAP logger
;; into a special mode where no data is written until either the profiled
;; application terminates or until the current ICP file is closed. Note
;; that opening an new ICP file will result in the second data set also
;; being collected in memory if the first was collected that way.
;; Default is Off.
;;
; InMemoryCollection=Off
; InMemoryCollection=On
;;
;;
;; EnableUIDisplay determines whether or not the logger loads its UI
;; components to show the the current profiling state and allow control
;; over profiling. Default is On.
;;
; EnableUIDisplay=Off
; EnableUIDisplay=On
;;
;;
;; Shutdown specifies whether, when the logger is started automatically, it
;; will shut down automatically ("Automatic", the default) or whether it
;; will continue running until manually shut down ("Manual"). The latter
;; behavior is useful when profiling a dynamically loaded component which
;; is loaded and unloaded and reloaded over the course of a single scenario.
;;
; Shutdown=Automatic
; Shutdown=Manual
;;
;;
;; MaxProcesses specifies the maximum number of processes which can be
;; profiled simultaneously. By default, this is 8.
;;
; MaxProcesses=8
;;
;;
;; MaxThreads specifies the maximum number of threads which can be profiled
;; simultaneously (across multiple processes). By default, this is 32 on
;; machines with 128MB of memory and is adjusted on a sliding scale for
;; machines with more RAM.
;;
; MaxThreads=64
;;
;;
;; NumberOfBuffers specifies the maximum number of buffers which can be in
;; use at one time. By default, this is set to the (MaxThreads + 1) (one
;; buffer per thread plus one extra for the index). This value must be
;; larger than MaxThreads or an error message will be issued.
;
NumberOfBuffers=256
;;
;;
;; SizeOfBuffers specifies the size (in "K") of I/O buffers to be used to
;; collecting profile data. By default, this is 64 (64k or 65535 bytes).
;; On a system with limited disks but plenty of available RAM, it may be
;; useful to increase the buffer size (keeping in mind that this is the
;; size used PER THREAD being profiled). Maximum size is 1024 (1 megabyte).
;; Minimum size is 4.
;;
; SizeOfBuffers=64
;;
;;
;; ClearProcessSecurityACL controls whether any special handling is done
;; relative to the ACL of a process handle. This may be necessary in
;; some cases when redirecting output to a new ICP file during a profile
;; run. Three settings are supported: 'default' (which is the default),
;; 'standard', and 'impersonating'. Default will not cause any special
;; ACL handling to take place. Standard should be used to clear process
;; security for a standard service application. Impersonating should be
;; used to clear process security for a service which is impersonating
;; another user. We recommend contacting ICAPSUP before making use of
;; these settings if you are unsure about whether or not they are needed.
;;
; ClearProcessSecurityACL=default
; ClearProcessSecurityACL=standard
; ClearProcessSecurityACL=impersonating
;;
;;
;;****************************************************************************
;; The following settings are IceCAP-specific (i.e. don't apply if collecting
;; data for DLP, and are read ONCE when the logger is initializing. These
;; settings must be contained in the [IceCAP] section as well.
;;****************************************************************************
;;
;; P6PerfCounter specifies an additional P6 performance counter whose value
;; is to be collected in addition to time. The optional qualifier specifies
;; to which Ring the counter should apply (0 for Kernel, 3 for User, * or
;; blank for all). By default, this option collects no additional data. If
;; data is collected, it will be recorded in the User1 counter value slot.
;; If the P6 counter C0,* is added, IceCAP analysis will automatically
;; calculate CPI for you. (ie. P6PerfCounter=C0,*)
;;
; P6PerfCounter=24,*
;;
;;
;; For some P6 Performance Counters, a Unit Mask can be used to fine-tune
;; what is being collected. To allow users to specify this unit mask, the
;; following new INI setting has been added. Default value is 0.
;;
; P6PerfCounterUnitMask=0
; P6PerfCounterUnitMask=f
;;
;; UserCounter specifies one or more optional additional user-defined
;; counters whose value should be recorded with the IceCAP time (and
;; possibly P6 counter) data. At present, IceCAP supports a maximum of 15
;; user counter values, which includes a P6 counter if one is being
;; recorded. To specify a user counter, the user specifies a DLL name,
;; a counterinfo function name, and a counter initialization function
;; name. See the IceCAP documentation for additional info about
;; writing a User counter.
;;
; UserCounter=NTUserPerf.dll,GetNtCounterInfo,InitNtCounters
;;
;;
;; CollectPFEvents determines whether page fault data is collected and if so,
;; for which processes. It can take the following values:
;; all - pagefault data is collected for all processes in the system
;; profiled - pagefault data is collected only for profiled processes
;; none - default - no pagefault data is collected
;; Note: If you are collecting kernel-mode profiles, CollectPFEvents=profiled
;; will have the same effect of CollectPFEvents=all.
;;
; CollectPFEvents=all
; CollectPFEvents=profiled
; CollectPFEvents=none
;;
;;
;; If CollectPFEvents is not set to 'none', then the PageFaultCategory setting
;; determines what types of page faults are recorded. It can take one or more
;; of the following values (comma separated):
;; Hard (default), Transition, DemandZero, CopyOnWrite, Guard,
;; Soft (equivalent to "Transition, DemandZero,CopyOnWrite,Guard"),
;; All (equivalent to all of the above)
;; Note: Due to a bug in WMI, we cannot collect guard page fault data. This
;; bug exists in Windows 2000 and current Whistler builds, and it is not
;; expected to be fixed in the near term.
;;
; PageFaultCategory=Hard
; PageFaultCategory=Transition
; PageFaultCategory=Soft
; PageFaultCategory=All
;;
;; If CollectPFEvents is not set to 'none', then the WMIBuffers setting determines
;; the number of buffers that the WMI subsystem will allocate for its own use.
;; The size of the buffers is the specified below. The default is 32 buffers.
;;
; WMIBuffers=32
;;
;;
;; If CollectPFEvents is not set to 'none', then the WMIBufferSize setting
;; determines the size (in K) of the buffers that the WMI subsystem will
;; allocate for its own use. The default is 4K buffers.
;;
; WMIBufferSize=4
;;
;;
;;
;;****************************************************************************
;; The following fields are read ONCE when the logger is initializing. If
;; the logger is started manually, they will be read from the [IceCAP] section.
;; If the logger is started from an instrumented process, it will first look
;; for a section with that process's base application name ([WinWord] for
;; example), then if it doesn't find the entry, it will look in the [IceCAP]
;; section.
;;****************************************************************************
;;
;; DetectKernelTransitions determines whether or not a P6/PII performance
;; counter is used to track transitions between user mode and kernel mode.
;; By default, this is On for P6/PII processors, and Off for vanilla
;; Pentium processors. By turning this off, only Elapsed time can be
;; measured. It can, however, reduce collection overhead as a result.
;;
; DetectKernelTransitions=On
; DetectKernelTransitions=Off
;;
;;
;; Output overrides the path and/or filename used for the log file (ICP
;; file). For additional details, please refer to the documentation.
;;
; Output=C:\ICPFILES
; Output=C:\ICPFILES\SCENARIO1.ICP
;;
;; Additional, application-specific sections can be added to specify profile
;; settings for specific processes.
;;
[WinWord]
;;
; Profile=On
; Profile=Off
;;