Source code of Windows XP (NT5)
You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
|
|
;/*++ BUILD Version: 0001 // Increment this if a change has global effects
; ;Copyright (c) 1991 Microsoft Corporation ; ;Module Name: ; ; pcmciamc.h ; ;Abstract: ; ; Constant definitions for the PCMCIA error values ; ;Author: ; ; Bob Rinne (BobRi) 8-Nov-1994 ; ;Revision History: ; ;--*/ ; ; ;//
;// Status values are 32 bit values layed out as follows:
;//
;// 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
;// 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
;// +---+-+-------------------------+-------------------------------+
;// |Sev|C| Facility | Code |
;// +---+-+-------------------------+-------------------------------+
;//
;// where
;//
;// Sev - is the severity code
;//
;// 00 - Success
;// 01 - Informational
;// 10 - Warning
;// 11 - Error
;//
;// C - is the Customer code flag
;//
;// Facility - is the facility code
;//
;// Code - is the facility's status code
;//
; MessageIdTypedef=NTSTATUS
SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS Informational=0x1:STATUS_SEVERITY_INFORMATIONAL Warning=0x2:STATUS_SEVERITY_WARNING Error=0x3:STATUS_SEVERITY_ERROR )
FacilityNames=(System=0x0 RpcRuntime=0x2:FACILITY_RPC_RUNTIME RpcStubs=0x3:FACILITY_RPC_STUBS Io=0x4:FACILITY_IO_ERROR_CODE Pcmcia=0x6:FACILITY_PCMCIA_ERROR_CODE )
MessageId=0x0001 Facility=Pcmcia Severity=Error SymbolicName=PCMCIA_NO_MEMORY_WINDOW Language=English A memory window for reading the PCCARD configuration could not be found. No PCMCIA PCCARDS were configured. .
MessageId=0x0002 Facility=Pcmcia Severity=Error SymbolicName=PCMCIA_NO_IRQ Language=English An interrupt for a PCMCIA PCCARD could not be allocated. .
MessageId=0x0003 Facility=Pcmcia Severity=Error SymbolicName=PCMCIA_NO_ATA Language=English The IDE compatible PCMCIA disk was not configured. .
MessageId=0x0004 Facility=Pcmcia Severity=Error SymbolicName=PCMCIA_BAD_TUPLE_INFORMATION Language=English The PCMCIA tuple information for the PCCARD in socket %2 could not be parsed. .
MessageId=0x0005 Facility=Pcmcia Severity=Informational SymbolicName=PCMCIA_NO_CONFIGURATION Language=English There is no configuration information for the PCCARD "%2". .
MessageId=0x0006 Facility=Pcmcia Severity=Error SymbolicName=PCMCIA_BAD_IRQ_NETWORK Language=English The IRQ of %2 was selected for a network PCMCIA PCCARD. This IRQ is not supported for PCCARDs on this system. For network service, please change the configuration. .
MessageId=0x0007 Facility=Pcmcia Severity=Error SymbolicName=PCMCIA_NO_CONTROLLER_IRQ Language=English No IRQ available for status change interrupts for PCMCIA controller: this controller will not be able to detect hot insertions/removals of PC-Cards. .
MessageId=0x0008 Facility=Pcmcia Severity=Error SymbolicName=PCMCIA_NO_RESOURCES Language=English The PCMCIA controller failed to start because of unavailable system resources. .
MessageId=0x0009 Facility=Pcmcia Severity=Error SymbolicName=PCMCIA_DEVICE_POWER_ERROR Language=English The PCMCIA controller encountered an error powering up the inserted device. .
MessageId=0x000A Facility=Pcmcia Severity=Error SymbolicName=PCMCIA_DEVICE_ENUMERATION_ERROR Language=English The PCMCIA controller encountered an error reading the device configuration data. .
|