|
|
;----------------------------------------------------------------------------- [Responses] ; This section is temporary.
;----------------------------------------------------------------------------- [SprintNet, Standard]
DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600
; The next two lines ignore logon banners COMMAND= OK=<ignore>
; The @ characters sets the SprintNet PAD for 8 databit communication. COMMAND=@ NoResponse
; The D character requests a 9600 speed. COMMAND=D<cr> ; We dont care about the response so we ignore it (unless modem has hung up). ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
; A carriage return to initialize the PAD read/write buffers COMMAND=<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
; Set X.3 settings on the PAD which make it work well with RAS. Broken into ; two parts since the line is too long. COMMAND=SET 1:0,2:0,3:0,4:1,5:0,6:1,7:0,8:0,9:0,10:0<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
; Set the other half of X.3 parameters COMMAND=SET 12:0,13:0,14:0,15:0,16:0,17:0,18:0,19:0,20:0,22:0<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
; Finally try to call RAS X25 server COMMAND=C <x25address>*<UserData><cr>
CONNECT=<match>" CONNECT" ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR_DIAGNOSTICS=<cr><lf><Diagnostics> ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
; CONNECT response means that the connection completed fine. ; ERROR_DIAGNOISTICS response means connection attempt failed - the X25 ; DIAGNOSTIC information will be extracted from the response and sent to the ; user. ; ERROR_NO_CARRIER means that the remote modem hung up. ; ERROR resonses are for generic failures.
;----------------------------------------------------------------------------- [SprintNet, Alternate]
; Connections can be made more reliably in some SprintNet locations if ; there are some delays near the beginning of the pad.inf entry. As a ; general rule of thumb use this entry with older, slower (2400 bps) ; locations.
DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600
; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND= NoResponse
; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND= NoResponse
; The @ characters sets the SprintNet PAD for 8 databit communication. COMMAND=@ NoResponse
COMMAND= NoResponse
; The D character requests a 9600 speed. COMMAND=D<cr> ; We dont care about the response so we ignore it (unless modem has hung up). ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
; A carriage return to initialize the PAD read/write buffers COMMAND=<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
; Set X.3 settings on the PAD which make it work well with RAS. Broken into ; two parts since the line is too long. COMMAND=SET 1:0,2:0,3:0,4:1,5:0,6:1,7:0,8:0,9:0,10:0<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
; Set the other half of X.3 parameters COMMAND=SET 12:0,13:0,14:0,15:0,16:0,17:0,18:0,19:0,20:0,22:0<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
; Finally try to call RAS X25 server COMMAND=C <x25address>*<UserData><cr>
CONNECT=<match>" CONNECT" ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR_DIAGNOSTICS=<cr><lf><Diagnostics> ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
; CONNECT response means that the connection completed fine. ; ERROR_DIAGNOISTICS response means connection attempt failed - the X25 ; DIAGNOSTIC information will be extracted from the response and sent to the ; user. ; ERROR_NO_CARRIER means that the remote modem hung up. ; ERROR resonses are for generic failures.
;----------------------------------------------------------------------------- [InfoNet]
DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=2400
; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND= NoResponse
; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND= NoResponse
COMMAND=<cr> ; We dont care about the response so we ignore it (unless modem has hung up). ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
COMMAND=<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
COMMAND=X<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
; Set X.3 settings on the PAD which make it work well with RAS. Broken into ; two parts since the line is too long. COMMAND=SET 1:126,2:1,3:0,4:1,5:0,6:1,7:0,8:0,9:0,10:0<cr> NoResponse
COMMAND= NoResponse
; Set the other half of X.3 parameters COMMAND=SET 12:0,13:0,14:0,15:0,16:0,17:0,18:0,19:0,20:0,21:0,22:0<cr> NoResponse
COMMAND= NoResponse
; Try to call RAS X25 server COMMAND=<x25address><cr><lf>
OK=<match>"COM" ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
; CONNECT response means that the connection completed fine. ; ERROR_DIAGNOISTICS response means connection attempt failed - the X25 ; DIAGNOSTIC information will be extracted from the response and sent ; to the user. ; ERROR_NO_CARRIER means that the remote modem hung up. ; ERROR resonses are for generic failures.
; Finally set no escape and no echo COMMAND=SET 1:0,2:0<cr> NoResponse
;----------------------------------------------------------------------------- [InfoNet, Alternate]
DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600
; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND= NoResponse
; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND= NoResponse
COMMAND=<cr> ; We dont care about the response so we ignore it (unless modem has hung up). ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
COMMAND=<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
COMMAND=X<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
; Set X.3 settings on the PAD which make it work well with RAS. Broken into ; two parts since the line is too long. ;COMMAND=SET 1:126,2:1,3:0,4:1,5:0,6:1,7:0,8:0,9:0,10:0<cr> COMMAND=SET 1:126,2:1,3:0,4:1,5:0,6:1,7:2,9:0,10:0<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR=<match>"ERR" OK=<ignore>
; Set the other half of X.3 parameters COMMAND=SET 12:0,13:0,14:0,15:0,16:127,17:24,18:18,19:0,20:0,21:0,22:0<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR=<match>"ERR" OK=<ignore>
; Try to call RAS X25 server COMMAND=<x25address><cr><lf> OK=<ignore>
OK=<match>"COM" ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR_DIAGNOSTICS=<cr><lf><Diagnostics> ERROR=<match>"ERR"
; CONNECT response means that the connection completed fine. ; ERROR_DIAGNOISTICS response means connection attempt failed - the X25 ; DIAGNOSTIC information will be extracted from the response and sent ; to the user. ; ERROR_NO_CARRIER means that the remote modem hung up. ; ERROR resonses are for generic failures.
; Finally set no escape and no echo COMMAND=SET 1:0,2:0<cr> NoEcho ERROR=<match>"ERR" CONNECT=<ignore>
[Transpac]
DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=2400
; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND= NoResponse
; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND= NoResponse
; We dont care about the response so we ignore it (unless modem has hung up). ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<match>"TRANSPAC"
; Set X.3 settings on the PAD which make it work well with RAS. Broken into ; two parts since the line is too long. COMMAND=SET 1:1,2:1,3:0,4:1,5:0,6:1,7:0,9:0,10:0<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR=<match>"ERR" OK=<ignore>
; Set the other half of X.3 parameters COMMAND=SET 12:0,13:0,14:0,15:0,16:127,17:24,18:18,19:0,20:0,21:0,22:0<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR=<match>"ERR" OK=<ignore>
; Try to call RAS X25 server COMMAND=<x25address><cr><lf> OK=<ignore>
OK=<match>"COM" ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
; CONNECT response means that the connection completed fine. ; ERROR_DIAGNOISTICS response means connection attempt failed - the X25 ; DIAGNOSTIC information will be extracted from the response and sent ; to the user. ; ERROR_NO_CARRIER means that the remote modem hung up. ; ERROR resonses are for generic failures.
; Finally set no escape and no echo COMMAND=SET 1:0,2:0<cr> NoEcho CONNECT=<ignore>
;----------------------------------------------------------------------------- [Eicon X.PAD]
DEVICETYPE=pad DEFAULTOFF=
MAXCARRIERBPS=1200 MAXCONNECTBPS=1200
; ; INIT section. ; COMMAND_INIT=PAR 2<cr> NoEcho OK=par 2:<ignore> ERROR_DIAGNOSTICS=CLR <Diagnostics> ERROR=ERR<ignore>
; ; LISTEN section. ; COMMAND_LISTEN= NoEcho CONNECT=<match>"COM" ERROR_DIAGNOSTICS=CLR <Diagnostics> ERROR=ERR<ignore>
; ; CALL section. ; COMMAND_DIAL=<x25address><cr><lf> NoEcho CONNECT=<match>"COM" ERROR_DIAGNOSTICS=CLR CONF <cr><lf>CLR<Diagnostics> ERROR_DIAGNOSTICS=CLR <Diagnostics> ERROR=ERR<ignore>
;----------------------------------------------------------------------------- [Compuserve]
; Disclaimer: ; This script has been included for customer convenience, but has NOT been ; fully verified to work under all circumstances. Microsoft makes NO guarantees ; as to the performance of this script. Please contact Microsoft ; PSS NT support if you have problems or questions.
DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600
COMMAND= NoResponse
COMMAND=<cr> OK=<ignore>
COMMAND=+<cr> OK=<match>"Host Name:"
COMMAND=<x25address><cr> CONNECT=<match>"Connected" ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR_DIAGNOSTICS=<cr><lf><Diagnostics> ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
;----------------------------------------------------------------------------------- [SITA Group Network]
; Disclaimer: ; This script has been included for customer convenience, but has NOT been ; fully verified to work under all circumstances. Microsoft makes NO guarantees ; as to the performance of this script. Please contact Microsoft ; PSS NT support if you have problems or questions. ; PLEASE SEE COMMENTS BELOW REGARDING USAGE OF THE "User Data:" ; and "Facilities:" FIELDS IN RAS WHEN USING THIS SITA SCRIPT.
DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600
COMMAND=...<cr> OK=<match>"SITA NETWORK:"
; Enter your NUI number in the Remote Access program's X.25 Settings "User Data:" field. COMMAND=<UserData><cr> OK=<ignore>
; Enter your x.25 password in the Remote Access program's X.25 Settings "Facilities:" field. COMMAND=<Facilities><cr> OK=<match>"active" ERROR_DIAGNOSTICS=<cr><lf><cr><lf><lf><Diagnostics> ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
COMMAND=PROF 6<cr> NoResponse
COMMAND= NoResponse
COMMAND=SET 2:1<cr> OK=<ignore>
COMMAND= NoResponse
COMMAND=SET 4:1,6:1,16:0,17:0,18:0,19:0,21:0<cr> OK=<ignore>
COMMAND= NoResponse
COMMAND=SET 118:0,119:0,120:0<cr> OK=<ignore>
COMMAND=PAR?<cr> OK=<ignore>
COMMAND=SET 2:0<cr> NoResponse
COMMAND= NoResponse
COMMAND=<x25address><cr> CONNECT=<match>"connected" ;CONNECT=<ignore> ERROR_DIAGNOSTICS=<cr><lf><cr><lf><lf><Diagnostics> ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
;----------------------------------------------------------------------------------- [Alascom/Tymnet/MCI]
; Disclaimer: ; This script has been included for customer convenience, but has NOT been ; fully verified to work under all circumstances. Microsoft makes NO guarantees ; as to the performance of this script. Please contact Microsoft ; PSS NT support if you have problems or questions. ; NOTE: Whether your X.25 account is set up for a single x.121 identifier or a ; username/password combination, they both are entered in the Remote Access program's ; "X.25 Settings" dialog box in the "X.121 Address:" field. ; A username and password combination is entered simply by separating them with a ; SEMICOLON, e.g.: John;mypass ; where "John" is the username and "mypass" is the password.
DEFAULTOFF= MAXCARRIERBPS=9600 MAXCONNECTBPS=9600
; The "o" changes the terminal identifer so that the x.25 network responses are ; readable and don't appear as garbage. No carriage return is required after it. COMMAND=o OK=<match>"log in:" ERROR_DIAGNOSTICS=<cr><lf><Diagnostics> ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
; Note: The "<h08>" represents a Ctrl-H or Backspace character which turns the ; echo facility in the x.25 network off which interferes with RAS operation. COMMAND=<h08><x25address><cr> CONNECT=<match>"connected" ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR_DIAGNOSTICS=<cr><lf><Diagnostics> ERROR_DIAGNOSTICS=<lf><cr><lf><Diagnostics>
[Telematics]
DEFAULTOFF= MAXCARRIERBPS=19200 MAXCONNECTBPS=19200
; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND=<cr> ; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND=<cr>
;The next line will initiate AUTOBAUD/AUTOPARITY with the ;Telematics PAD COMMAND=..<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<match>"*"
; Finally try to call RAS X25 server COMMAND=<x25address><cr>
CONNECT=<match>"com"
[InfoNet X25]
DEFAULTOFF= MAXCARRIERBPS=2400 MAXCONNECTBPS=2400
; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND= NoResponse
; The next line will give a delay of 2 secs - allowing the PAD to initialize COMMAND= NoResponse
COMMAND=<cr> ; We dont care about the response so we ignore it (unless modem has hung up). ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
COMMAND=<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
COMMAND=SET 2:1<cr> NoResponse
COMMAND=X<cr> ERROR_NO_CARRIER=<match>"NO CARRIER" OK=<ignore>
; Try to call RAS X25 server COMMAND=<x25address><cr><lf>
OK=<match>"COM" ERROR_NO_CARRIER=<match>"NO CARRIER" ERROR_DIAGNOSTICS=<cr><lf><Diagnostics>
; CONNECT response means that the connection completed fine. ; ERROR_DIAGNOISTICS response means connection attempt failed - the X25 ; DIAGNOSTIC information will be extracted from the response and sent ; to the user. ; ERROR_NO_CARRIER means that the remote modem hung up. ; ERROR resonses are for generic failures.
|