Source code of Windows XP (NT5)
You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
|
|
;/*++ BUILD Version: 0001 // Increment this if a change has global effects
; ;Copyright (c) 1993 Microsoft Corporation ; ;Module Name: ; ; scrcp8t.mc ; ;Abstract: ; ; Constant definitions for the I/O error code log values. ; ;Revision History: ; ;--*/ ; ;#ifndef _TLP3TLOG_ ;#define _TLP3TLOG_ ; ;//
;// Status values are 32 bit values layed out as follows:
;//
;// 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
;// 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
;// +---+-+-------------------------+-------------------------------+
;// |Sev|C| Facility | Code |
;// +---+-+-------------------------+-------------------------------+
;//
;// where
;//
;// Sev - is the severity code
;//
;// 00 - Success
;// 01 - Informational
;// 10 - Warning
;// 11 - Error
;//
;// C - is the Customer code flag
;//
;// Facility - is the facility code
;//
;// Code - is the facility's status code
;//
; MessageIdTypedef=NTSTATUS
SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS Informational=0x1:STATUS_SEVERITY_INFORMATIONAL Warning=0x2:STATUS_SEVERITY_WARNING Error=0x3:STATUS_SEVERITY_ERROR )
FacilityNames=(System=0x0 RpcRuntime=0x2:FACILITY_RPC_RUNTIME RpcStubs=0x3:FACILITY_RPC_STUBS Io=0x4:FACILITY_IO_ERROR_CODE Smartcard=0x10:FACILITY_SCARD )
MessageId=0x0001 Facility=Io Severity=Error SymbolicName=TLP3_CANT_CREATE_DEVICE Language=English A new device cannot be created due to a system call failure. . MessageId=0x0002 Facility=Io Severity=Error SymbolicName=TLP3_NO_MEMORY Language=English The system does not have enough memory. . MessageId=0x0003 Facility=Smartcard Severity=Error SymbolicName=TLP3_BUFFER_TOO_SMALL Language=English An internal i/o buffer is too small. . MessageId=0x0004 Facility=Io Severity=Error SymbolicName=TLP3_CANT_CONNECT_TO_ASSIGNED_PORT Language=English Internal error: Cannot connect to assigned serial port. . MessageId=0x0005 Facility=Io Severity=Error SymbolicName=TLP3_CANT_CREATE_MORE_DEVICES Language=English The maximum number of devices has already been created. A new device cannot be created. . MessageId=0x0006 Facility=Io Severity=Informational SymbolicName=TLP3_WRONG_LIB_VERSION Language=English The version of the dependency driver smclib.sys is not compatbile to this driver. . MessageId=0x0007 Facility=Io Severity=Informational SymbolicName=TLP3_IRQ_BUSY Language=English The current serial port cannot be used because it uses a shared interrupt which is already in use. Please connect the smart card reader to a different serial port. . ;#endif /* _TLP3TLOG_ */
|