Source code of Windows XP (NT5)
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

201 lines
4.6 KiB

  1. MessageId=10000 SymbolicName=MSG_FIRST
  2. Language=English
  3. .
  4. MessageId=10001 SymbolicName=MSG_OUT_OF_MEMORY
  5. Language=English
  6. The application was unable to allocate sufficient resources.
  7. Please close any other applications.
  8. %0
  9. .
  10. MessageId=10002 SymbolicName=MSG_NOT_AN_ADMINISTRATOR
  11. Language=English
  12. You must be an administrator to run this application.
  13. %0
  14. .
  15. MessageId=10003 SymbolicName=MSG_ALREADY_RUNNING
  16. Language=English
  17. Another copy of this application is already running.
  18. %0
  19. .
  20. MessageId=10004 SymbolicName=MSG_IDENTIFY_SYSPREP
  21. Language=English
  22. Running System Preparation Tool (Sysprep) can modify this computer's security
  23. settings.
  24. If allowed under your license agreement, you may use Sysprep to prepare an installation of Windows that you can deploy to multiple destination computers.
  25. After you run Sysprep, Windows will automatically shut down.
  26. %0
  27. .
  28. MessageId=10005 SymbolicName=MSG_REGISTRY_ERROR
  29. Language=English
  30. An error occurred while trying to update your registry.
  31. Unable to continue.
  32. %0
  33. .
  34. MessageId=10006 SymbolicName=MSG_NO_SUPPORT
  35. Language=English
  36. Setupcl.exe is not present.
  37. Sysprep cannot run on this system.
  38. %0
  39. .
  40. MessageId=10007 SymbolicName=MSG_OS_INCOMPATIBILITY
  41. Language=English
  42. There is an incompatiblity between this tool and the current operating system.
  43. Unable to continue.
  44. %0
  45. .
  46. MessageId=10008 SymbolicName=MSG_USAGE
  47. Language=English
  48. Command Parameter Usage:
  49. -quiet%t%tDo not show confirmation dialog boxes.
  50. -nosidgen%t%tDo not regenerate security ID upon reboot.
  51. -pnp%t%tForce Plug and Play refresh on next reboot.
  52. -reboot%t%tReboot after SYSPREP.EXE has completed.
  53. -noreboot%tShutdown without a reboot.
  54. -clean%t%tClean out critical devices.
  55. -forceshutdown%tForce shutdown instead of poweroff.
  56. -factory%t%tFactory preinstallation.
  57. -reseal%t%tReseal machine after running FACTORY.EXE.
  58. -mini%t%tRun Mini-Setup after reboot.
  59. -activated%tDo not reset grace period for activation.
  60. -bmsd%t%tBuilds list of all available mass storage devices in sysprep.inf.
  61. %0
  62. .
  63. MessageId=10009 SymbolicName=MSG_DOMAIN_INCOMPATIBILITY
  64. Language=English
  65. Sysprep can not be run on a machine which is a member of a network domain.
  66. Please remove the computer from the domain and rerun Sysprep.
  67. %0
  68. .
  69. MessageId=10010 SymbolicName=MSG_CANNOT_RESEAL
  70. Language=English
  71. Sysprep can not reseal a machine that has not been prepared for factory floor pre-installation.
  72. Please run 'sysprep -factory' prior to using the reseal option
  73. %0
  74. .
  75. MessageId=10011 SymbolicName=MSG_NO_FACTORYEXE
  76. Language=English
  77. Sysprep was unable to locate FACTORY.EXE.
  78. Please provide FACTORY.EXE before running 'sysprep -factory'.
  79. %0
  80. .
  81. MessageId=10012 SymbolicName=MSG_NO_MINISETUP
  82. Language=English
  83. Mini-Setup is not available for Personal editions.
  84. %0
  85. .
  86. MessageId=10013 SymbolicName=MSG_SETUPFACTORYFLOOR_ERROR
  87. Language=English
  88. Setup For Factory Floor failed!
  89. %0
  90. .
  91. MessageId=10015 SymbolicName=MSG_RESEAL_ERROR
  92. Language=English
  93. Reseal machine failed!
  94. %0
  95. .
  96. MessageId=10017 SymbolicName=MSG_COMMON_ERROR
  97. Language=English
  98. Common reseal of machine failed!
  99. %0
  100. .
  101. MessageId=10018 SymbolicName=MSG_REARM_ERROR
  102. Language=English
  103. Your grace period limit has been reached and will not be reset.
  104. %0
  105. .
  106. MessageId=10019 SymbolicName=MSG_USAGE_COMBINATIONS
  107. Language=English
  108. Invalid combination of parameters. Usage%:
  109. sysprep -factory [-quiet] [-nosidgen] [-activated] [-noreboot | -reboot | -forceshutdown]
  110. sysprep -reseal [-quiet] [-nosidgen] [-activated] [-mini [-pnp]] [-noreboot | -reboot | -forceshutdown]
  111. sysprep -clean [-quiet]
  112. sysprep -audit [-quiet]
  113. %0
  114. .
  115. MessageId=10020 SymbolicName=MSG_NO_PNP
  116. Language=English
  117. PNP legacy device detection is not available for Personal editions.
  118. %0
  119. .
  120. MessageId=10021 SymbolicName=MSG_DO_GEN_SIDS
  121. Language=English
  122. You chose not to regenerate security identifiers (SIDs) on the next reboot.
  123. If this is an image, you must regenerate SIDs when you reseal.
  124. To continue without regenerating the SIDs, click OK. To go back and change this setting, click Cancel.
  125. %0
  126. .
  127. MessageId=10022 SymbolicName=MSG_DONT_GEN_SIDS
  128. Language=English
  129. You chose to regenerate security identifiers (SIDs) on the next reboot.
  130. You only need to regenerate SIDs if you plan to make an image of the installation after shutdown.
  131. To regenerate SIDs, click OK. To go back and change this setting, click Cancel.
  132. %0
  133. .
  134. MessageId=10023 SymbolicName=MSG_SETDEFAULTS_NOTFOUND
  135. Language=English
  136. Application "%1" (%2) cannot be marked as default because its registration is incomplete.
  137. %0
  138. .
  139. MessageId=10024 SymbolicName=MSG_NOT_ALLOWED
  140. Language=English
  141. The OPK tools have been updated for the version of Windows you are installing.
  142. Please use the updated version, available on the Windows OPK CD.
  143. %0
  144. .