Source code of Windows XP (NT5)
You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
|
|
;/*++ BUILD Version: 0001 // Increment this if a change has global effects
; ;Copyright (c) 1995 Microsoft Corporation ; ;Module Name: ; ; joylog.mc ; ;Abstract: ; ; Joystick driver error message definitions. ; ;Author: ; ; edbriggs 12-25-1993 ; ;Revision History: ; ;--*/ ; ;#ifndef _JOYLOG_ ;#define _JOYLOG_ ;//
;// Status values are 32 bit values layed out as follows:
;//
;// 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
;// 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
;// +---+-+-------------------------+-------------------------------+
;// |Sev|C| Facility | Code |
;// +---+-+-------------------------+-------------------------------+
;//
;// where
;//
;// Sev - is the severity code
;//
;// 00 - Success
;// 01 - Informational
;// 10 - Warning
;// 11 - Error
;//
;// C - is the Customer code flag
;//
;// Facility - is the facility code
;//
;// Code - is the facility's status code
;//
; MessageIdTypedef=NTSTATUS
SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS Informational=0x1:STATUS_SEVERITY_INFORMATIONAL Warning=0x2:STATUS_SEVERITY_WARNING Error=0x3:STATUS_SEVERITY_ERROR )
FacilityNames=(System=0x0 RpcRuntime=0x2:FACILITY_RPC_RUNTIME RpcStubs=0x3:FACILITY_RPC_STUBS Io=0x4:FACILITY_IO_ERROR_CODE Joystick=0x7:FACILITY_JOYSTICK_ERROR_CODE )
MessageId=0x0003 Facility=Joystick Severity=Error SymbolicName=JOY_INSUFFICIENT_RESOURCES Language=English Not enough memory was available to allocate internal storage needed for the device %1. .
MessageId=0x0004 Facility=Joystick Severity=Error SymbolicName=JOY_REGISTERS_NOT_MAPPED Language=English The hardware locations for %1 could not be translated to something the memory management system could understand. .
MessageId=0x0005 Facility=Joystick Severity=Error SymbolicName=JOY_ADDRESS_CONFLICT Language=English The hardware addresses for %1 are already in use by another device. .
MessageId=0x0006 Facility=Joystick Severity=Error SymbolicName=JOY_NOT_ENOUGH_CONFIG_INFO Language=English Some registry configuration information was incomplete. .
MessageId=0x0007 Facility=Joystick Severity=Error SymbolicName=JOY_INVALID_CONFIG_INFO Language=English The registry parameters are invalid for this device. .
MessageId=0x000D Facility=Joystick Severity=Informational SymbolicName=JOY_USER_OVERRIDE Language=English User configuration data is overriding default configuration data. .
MessageId=0x000E Facility=Joystick Severity=Error SymbolicName=JOY_DEVICE_TOO_HIGH Language=English The user specified port is too high in physical memory. .
MessageId=0x000F Facility=Joystick Severity=Error SymbolicName=JOY_CONTROL_OVERLAP Language=English The control registers for the port overlaps with a previous ports control registers. .
MessageId=0x0013 Facility=Joystick Severity=Informational SymbolicName=JOY_DISABLED_PORT Language=English Disabling port %1 as requested by the configuration data. .
MessageId=0x0014 Facility=Joystick Severity=Error SymbolicName=JOY_DEVICE_DISCONNECTED Language=English No reponse within timeout suggests the device is unplugged %1. .
; ;#endif _JOYLOG_ ;
|