Printer-MIB DEFINITIONS ::= BEGIN -- -- Microsoft extracted from RFC1759 and made one change only: -- line 3033 changed from MAX-ACCESS not-accessible to MAX-ACCESS read-only -- IMPORTS MODULE-IDENTITY,OBJECT-TYPE,experimental,Counter32,Integer32,TimeTicks,NOTIFICATION-TYPE,OBJECT-IDENTITY FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE,OBJECT-GROUP FROM SNMPv2-CONF hrDeviceIndex,hrStorageIndex FROM HOST-RESOURCES-MIB; printmib MODULE-IDENTITY LAST-UPDATED "9411250000Z" ORGANIZATION "IETF Printer MIB Working Group" CONTACT-INFO " Steven Waldbusser Postal: Carnegie Mellon University 4910 Forbes Ave Pittsburgh, PA, 15213 Tel: 412-268-6628 Fax: 412-268-4987 E-mail: waldbusser@cmu.edu" DESCRIPTION "The MIB module for management of printers." ::= { mib-2 43 } -- Textual conventions for this MIB module MediaUnit ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Units of measure for media dimensions." -- This is a type 1 enumeration. SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4) } CapacityUnit ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Units of measure for media capacity." -- This is a type 1 enumeration. SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4), sheets(8), feet(16), meters(17) } SubUnitStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Status of a printer sub-unit. The SubUnitStatus is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Transitioning. These values are: Availability value Available and Idle 0 000'b Available and Standby 2 010'b Available and Active 4 100'b Available and Busy 6 110'b Unavailable and OnRequest 1 001'b Unavailable because Broken 3 011'b Unknown 5 101'b Non-Critical No Non-Critical Alerts 0 Non-Critical Alerts 8 Critical No Critical Alerts 0 Critical Alerts 16 On-Line Intended state is On-Line 0 Intended state is Off-Line 32 Transitioning At intended state 0 Transitioning to intended state 64 " SYNTAX INTEGER (0..126) PresentOnOff ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Presence and configuration of a device or feature." -- This is a type 1 enumeration. SYNTAX INTEGER { other(1), on(3), off(4), notPresent(5) } CodedCharSet ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A coded character set value that specifies both a set of characters that may be used and an encoding (as one or more octets) that is used to represent the characters in the set. These values are to be used to identify the encoding employed for strings in the MIB where this is not fixed by the MIB. Some objects that allow a choice of coded character set are: the prtLocalizationCharacterSet object in the LocalizationTable and prtInterpreterDefaultCharSetIn. The prtGeneralCurrentLocalization and prtConsoleLocalization objects in turn contain the index in the LocalizationTable of the current localization (country, language, and coded character set) of the `description' objects and the console, respectively. The space of the coded character set enumeration has been divide into three regions. The first region (3-999) consists of coded character sets that have been standardized by some standard setting organization. This region is intended for standards that do not have subset implementations. The second region (1000-1999) is for the Unicode and ISO/IEC 10646 coded character sets together with a specification of a (set of) sub-repetoires that may occur. The third region (>1999) is intended for vendor specific coded character sets. NOTE: Unicode and ISO 10646 character coded data may be processed and stored in either Big Endian (most significant octet first) or Little Endian (least significant octet first) order. Intel x86, VAX, and Alpha/AXP architectures are examples of Little Endian processor architectures. Furthermore, in environments where either order may occur, so-called Unicode BYTE ORDER MARK (BOM) character (which is ISO 10646 ZERO WIDTH NO BREAK SPACE), coded as FEFF in two octets and 0000FEFF in four octets is used at the beginning of the data as a signature to indicate the order of the following data (See ISO 10646 Annex F). Thus either ordering and BOM may occur in print data streams sent to the interpreter. However, ISO 8824/8825 (ASN.1/BER) used by SNMP is quite clear that Big Endian order shall be used and BOM shall NOT be used in transmission in the protocol. Transmitting Unicode in Big Endian order in SNMP should not prove to be a hardship for Little Endian machines, since SNMP ASN.1/BER requires integers to be transmitted in Big Endian order as well. So SNMP implementations on Little Endian machines are already reversing the order of integers to make them Big Endian for transmission via SNMP. Also Unicode characters are usually treated as two-octet integers, not short text strings, so that it will be straightforward for Little Endian machines to reverse the order of Unicode character octets as well before transmitting them and after receiving them via the SNMP protocol. Where a given coded character set may be known by more than one name, the most commonly known name is used as the name of the enumeration and other names are shown in the comments. The comments also indicate where to find detailed information on the coded character set and briefly characterize its relationship to other similar coded character sets. The current list of character sets and their enumerated values used to reference them is contained in the IANA Character Set registry. The enum value is indicated by the MIBenum entry in the registry. The enum symbol is indicated by the Alias that starts with `cs' for character set. The IANA character sets registry is available via anonymous ftp. The ftp server is ftp.isi.edu. The subdirectory is /in-notes/iana/assignments/. The file name is character-sets. To add a character set to the IANA Registry: 1. Format an entry like those in the current list, omitting the MIBenum value. 2. Send the entry with a request to add the entry to the character set list to iana@ISI.EDU. 3. The IANA will supply a unique MIBenum value and update the list." -- This is a type 3 enumeration. SYNTAX INTEGER { other(1) -- used if the designated coded -- character set is not currently in -- the enumeration -- See IANA Registry for standard character sets in the -- MIBenum range of 3-999. -- See IANA Registry for Unicode and vendor-supplied -- combinations of ISO collections and character sets based -- on Unicode in the MIBenum range of 1000-1999. -- See IANA Registry for vendor developed character sets -- in the MIBenum range of 2000-xxxx. } -- The General Printer Group -- -- The general printer sub-unit is responsible for the overall control -- and status of the printer. There is exactly one general printer -- sub-unit in a printer. -- -- Implementation of every object in this group is mandatory. prtGeneral OBJECT IDENTIFIER ::= { printmib 5 } prtGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of general information per printer. Objects in this table are defined in various places in the MIB, nearby the groups to which they apply. They are all defined here to minimize the number of tables that would otherwise need to exist." ::= { prtGeneral 1 } prtGeneralEntry OBJECT-TYPE SYNTAX PrtGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry exists in this table for each device entry in the hostmib device table who's type is `printer'" INDEX { hrDeviceIndex } ::= { prtGeneralTable 1 } PrtGeneralEntry ::= SEQUENCE { -- Note that not all of the objects in this sequence are in the -- general printer group. prtGeneralConfigChanges Counter32, prtGeneralCurrentLocalization Integer32, prtGeneralReset INTEGER, prtGeneralCurrentOperator OCTET STRING, prtGeneralServicePerson OCTET STRING, prtInputDefaultIndex Integer32, prtOutputDefaultIndex Integer32, prtMarkerDefaultIndex Integer32, prtMediaPathDefaultIndex Integer32, prtConsoleLocalization Integer32, prtConsoleNumberOfDisplayLines Integer32, prtConsoleNumberOfDisplayChars Integer32, prtConsoleDisable INTEGER } prtGeneralConfigChanges OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counts configuration changes that change the capabilities of a printer, such as the addition/deletion of input/output bins, the addition/deletion of interpreters, or changes in media size. Such changes will often affect the capability of the printer to service certain types of print jobs. Management applications may cache infrequently changed configuration information about sub-units on the printer. This object should be incremented whenever the agent wishes such applications to invalidate that cache and re-download all of this configuration information, thereby signalling a change in the printer's configuration. For example, if an input tray that contained paper of different dimensions was added, this counter would be incremented. As an additional example, this counter would not be incremented when an input tray is removed or the level of an input device changes." ::= { prtGeneralEntry 1 } prtGeneralCurrentLocalization OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the prtLocalizationIndex corresponding to the current language, country, and character set to be used for localized string values that are identified as being dependent on the value of this object. Note that this object does not apply to localized strings in the prtConsole group or any object that is not identified as above." ::= { prtGeneralEntry 2 } prtGeneralReset OBJECT-TYPE -- This value is a type 3 enumeration SYNTAX INTEGER { notResetting(3), powerCycleReset(4), -- Cold Start resetToNVRAM(5), -- Warm Start resetToFactoryDefaults(6) -- Reset contents of -- NVRAM to factory defaults } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this value to `powerCycleReset', `resetToNVRAM', or `resetToFactoryDefaults' will result in the resetting of the printer. When read, this object will always have the value `notResetting(3)', and a SET of the value `notResetting' shall have no effect on the printer. Some of the defined values are optional. However, every implementation must support at least the values `notResetting' and resetToNVRAM'." ::= { prtGeneralEntry 3 } -- The Cover Table -- -- The cover portion of the General print sub-unit describes the -- covers and interlocks of the printer. The Cover Table has an -- entry for each cover and interlock. prtCover OBJECT IDENTIFIER ::= { printmib 6 } prtCoverTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtCoverEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the covers and interlocks of the printer." ::= { prtCover 1 } prtCoverEntry OBJECT-TYPE SYNTAX PrtCoverEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a cover or interlock. Entries may exist in the table for each device index whose device type is `printer'." INDEX { hrDeviceIndex, prtCoverIndex } ::= { prtCoverTable 1 } PrtCoverEntry ::= SEQUENCE { prtCoverIndex Integer32, prtCoverDescription OCTET STRING, prtCoverStatus INTEGER } prtCoverIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this Cover sub-unit. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new cover sub-units to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtCoverEntry 1 } prtCoverDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The manufacturer provided cover sub-mechanism name in the localization specified by prtGeneralCurrentLocalization." ::= { prtCoverEntry 2 } prtCoverStatus OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX INTEGER { other(1), doorOpen(3), doorClosed(4), interlockOpen(5), interlockClosed(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of this cover sub-unit." ::= { prtCoverEntry 3 } -- The Localization Table -- -- The localization portion of the General printer sub-unit is -- responsible for identifying the natural language, country, and -- character set in which character strings are expressed. There -- may be one or more localizations supported per printer. The -- available localizations are represented by the Localization table. prtLocalization OBJECT IDENTIFIER ::= { printmib 7 } prtLocalizationTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtLocalizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The available localizations in this printer." ::= { prtLocalization 1 } prtLocalizationEntry OBJECT-TYPE SYNTAX PrtLocalizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A description of a localization. Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtLocalizationIndex } ::= { prtLocalizationTable 1 } PrtLocalizationEntry ::= SEQUENCE { prtLocalizationIndex Integer32, prtLocalizationLanguage OCTET STRING, prtLocalizationCountry OCTET STRING, prtLocalizationCharacterSet CodedCharSet } prtLocalizationIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this localization entry. Although these values may change due to a major reconfiguration of the device (e.g., the addition of new Cover sub-units to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtLocalizationEntry 1 } prtLocalizationLanguage OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "A two character language code from ISO 639. Examples EN, GB, CA, FR, DE." ::= { prtLocalizationEntry 2 } prtLocalizationCountry OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "A two character country code from ISO 3166, a blank string (two space characters) shall indicate that the country is not defined. Examples: US, FR, DE, ..." ::= { prtLocalizationEntry 3 } prtLocalizationCharacterSet OBJECT-TYPE SYNTAX CodedCharSet MAX-ACCESS read-only STATUS current DESCRIPTION "The coded character set used for this localization." ::= { prtLocalizationEntry 4 } -- The System Resources Tables -- The Printer MIB makes use of the Host MIB to -- define system resources by referencing the storage -- and device groups of the print group. In order to -- determine, amongst multiple printers serviced by -- one agent, which printer owns a particular -- resource, the prtStorageRef and prtDeviceRef tables -- associate particular storage and device entries to -- printers. prtStorageRefTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtStorageRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtGeneral 2 } prtStorageRefEntry OBJECT-TYPE SYNTAX PrtStorageRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table will have an entry for each entry in the host MIB storage table that represents storage associated with a printer managed by this agent." INDEX { hrStorageIndex, prtStorageRefSeqNumber } ::= { prtStorageRefTable 1 } PrtStorageRefEntry ::= SEQUENCE { prtStorageRefSeqNumber Integer32, prtStorageRefIndex Integer32 } prtStorageRefSeqNumber OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This value will be unique amongst all entries with a common value of hrStorageIndex. This object allows a storage entry to point to the multiple printer devices with which it is associated." ::= { prtStorageRefEntry 1 } prtStorageRefIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the hrDeviceIndex of the printer device that this storageEntry is associated with." ::= { prtStorageRefEntry 2 } prtDeviceRefTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDeviceRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtGeneral 3 } prtDeviceRefEntry OBJECT-TYPE SYNTAX PrtDeviceRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table will have an entry for each entry in the host MIB device table that represents a device associated with a printer managed by this agent." INDEX { hrDeviceIndex, prtDeviceRefSeqNumber } ::= { prtDeviceRefTable 1 } PrtDeviceRefEntry ::= SEQUENCE { prtDeviceRefSeqNumber Integer32, prtDeviceRefIndex Integer32 } prtDeviceRefSeqNumber OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This value will be unique amongst all entries with a common value of hrDeviceIndex. This object allows a device entry to point to the multiple printer devices with which it is associated." ::= { prtDeviceRefEntry 1 } prtDeviceRefIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the hrDeviceIndex of the printer device that this deviceEntry is associated with." ::= { prtDeviceRefEntry 2 } -- The Responsible Party group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtGeneralCurrentOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the current human operator responsible for operating this printer. It is suggested that this string include information that would enable other humans to reach the operator, such as a phone number." ::= { prtGeneralEntry 4 } prtGeneralServicePerson OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the last human responsible for servicing this printer. It is suggested that this string include information that would enable other humans to reach the service person, such as a phone number." ::= { prtGeneralEntry 5 } -- The Input Group -- -- Input sub-units are managed as a tabular, indexed collection of -- possible devices capable of providing media for input to the printing -- process. Input sub-units typically have a location, a type, an -- identifier, a set of constraints on possible media sizes and -- potentially other media characteristics, and may be capable of -- indicating current status or capacity. -- -- Implementation of every object in this group is mandatory. prtInput OBJECT IDENTIFIER ::= { printmib 8 } prtInputDefaultIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtInputIndex corresponding to the default input sub-unit: that is, this object selects the default source of input media." ::= { prtGeneralEntry 6 } prtInputTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the devices capable of providing media for input to the printing process." ::= { prtInput 2 } prtInputEntry OBJECT-TYPE SYNTAX PrtInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Attributes of a device capable of providing media for input to the printing process. Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtInputIndex } ::= { prtInputTable 1 } PrtInputEntry ::= SEQUENCE { prtInputIndex Integer32, prtInputType INTEGER, prtInputDimUnit MediaUnit, prtInputMediaDimFeedDirDeclared Integer32, prtInputMediaDimXFeedDirDeclared Integer32, prtInputMediaDimFeedDirChosen Integer32, prtInputMediaDimXFeedDirChosen Integer32, prtInputCapacityUnit CapacityUnit, prtInputMaxCapacity Integer32, prtInputCurrentLevel Integer32, prtInputStatus SubUnitStatus, prtInputMediaName OCTET STRING, prtInputName OCTET STRING, prtInputVendorName OCTET STRING, prtInputModel OCTET STRING, prtInputVersion OCTET STRING, prtInputSerialNumber OCTET STRING, prtInputDescription OCTET STRING, prtInputSecurity PresentOnOff, prtInputMediaWeight Integer32, prtInputMediaType OCTET STRING, prtInputMediaColor OCTET STRING, prtInputMediaFormParts Integer32 } prtInputIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this input sub-unit. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new input sub-units to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtInputEntry 1 } prtInputType OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX INTEGER { other(1), unknown(2), sheetFeedAutoRemovableTray(3), sheetFeedAutoNonRemovableTray(4), sheetFeedManual(5), continuousRoll(6), continuousFanFold(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of technology (discriminated primarily according to feeder mechanism type) employed by the input sub-unit. Note, the Optional Input Class provides for a descriptor field to further qualify the other choice." ::= { prtInputEntry 2 } prtInputDimUnit OBJECT-TYPE SYNTAX MediaUnit MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measurement for use calculating and relaying dimensional values for this input sub-unit." ::= { prtInputEntry 3 } prtInputMediaDimFeedDirDeclared OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object provides the value of the declared dimension, in the feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The feed direction is the direction in which the media is fed on this sub-unit. This dimension is measured in input sub-unit dimensional units (prtInputDimUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests. Otherwise, the value may be changed. The value (-1) means other and specifically means that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown." ::= { prtInputEntry 4 } prtInputMediaDimXFeedDirDeclared OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object provides the value of the declared dimension, in the cross feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The cross feed direction is ninety degrees relative to the feed direction associated with this sub-unit. This dimension is measured in input sub-unit dimensional units (prtInputDimUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests. Otherwise, the value may be changed. The value (-1) means other and specifically means that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown." ::= { prtInputEntry 5 } prtInputMediaDimFeedDirChosen OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The printer will act as if media of the chosen dimension (in the feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. Feed dimension measurements are taken parallel relative to the feed direction associated with that sub-unit and are in input sub-unit dimensional units (DimUnit). If the printer supports the declared dimension, the granted dimension is the same as the declared dimension. If not, the granted dimension is set to the closest dimension that the printer supports when the declared dimension is set. The value (-1) means other and specifically indicates that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown." ::= { prtInputEntry 6 } prtInputMediaDimXFeedDirChosen OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The printer will act as if media of the chosen dimension (in the cross feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. The cross feed direction is ninety degrees relative to the feed direction associated with this sub-unit. This dimension is measured in input sub-unit dimensional units (DimUnit). If the printer supports the declared dimension, the granted dimension is the same as the declared dimension. If not, the granted dimension is set to the closest dimension that the printer supports when the declared dimension is set. The value (-1) means other and specifically indicates that this sub-unit places no restriction on this parameter. The value (-2) indicates unknown." ::= { prtInputEntry 7 } prtInputCapacityUnit OBJECT-TYPE SYNTAX CapacityUnit MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measurement for use in calculating and relaying capacity values for this input sub-unit." ::= { prtInputEntry 8 } prtInputMaxCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum capacity of the input sub-unit in input sub-unit capacity units (CapacityUnit). There is no convention associated with the media itself so this value reflects claimed capacity. If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Contol Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown." ::= { prtInputEntry 9 } prtInputCurrentLevel OBJECT-TYPE SYNTAX Integer32 -- in capacity units (CapacityUnit). MAX-ACCESS read-write STATUS current DESCRIPTION "The current capacity of the input sub-unit in input sub-unit capacity units (CapacityUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Contol Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. The value (-3) means that the printer knows that at least one unit remains." ::= { prtInputEntry 10 } prtInputStatus OBJECT-TYPE SYNTAX SubUnitStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of this input sub-unit." ::= { prtInputEntry 11 } prtInputMediaName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "A description of the media contained in this input sub-unit; This description is intended for display to a human operator. This description is not processed by the printer. It is used to provide information not expressible in terms of the other media attributes (e.g. prtInputMediaDimFeedDirChosen, prtInputMediaDimXFeedDirChosen, prtInputMediaWeight, prtInputMediaType). An example would be `legal tender bond paper'." ::= { prtInputEntry 12 } -- INPUT MEASUREMENT -- -- _______ | | -- ^ | | -- | | | | -- | |_ _ _ _ _ _ _ _ _ _ _| _________________ |direction -- | | | ^ v -- MaxCapacity | | | -- | | Sheets left in tray | CurrentLevel -- | | | | -- v | | v -- _______ +_____________________+ _______ -- The Extended Input Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtInputName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name assigned to this input sub-unit." ::= { prtInputEntry 13 } prtInputVendorName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor name of this input sub-unit." ::= { prtInputEntry 14 } prtInputModel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The model name of this input sub-unit." ::= { prtInputEntry 15 } prtInputVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of this input sub-unit." ::= { prtInputEntry 16 } prtInputSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number assigned to this input sub-unit." ::= { prtInputEntry 17 } prtInputDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A free-form text description of this input sub-unit in the localization specified by prtGeneralCurrentLocalization." ::= { prtInputEntry 18 } prtInputSecurity OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if this input sub-unit has some security associated with it." ::= { prtInputEntry 19 } -- The Input Media Group -- -- The Input Media Group supports identification of media installed -- or available for use on a printing device. Medium resources are -- identified by name, and include a collection of characteristic -- attributes that may further be used for selection and management -- of them. The Input Media group consists of a set of optional -- "columns" in the Input Table. In this manner, a minimally -- conforming implementation may choose to not support reporting -- of media resources if it cannot do so. -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtInputMediaWeight OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The weight of the medium associated with this input sub-unit in grams / per meter squared. The value (-2) means unknown." ::= { prtInputEntry 20 } prtInputMediaType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the type of medium associated with this input sub-unit. This name need not be processed by the printer; it might simply be displayed to an operator. The standardized string values from ISO 10175 (DPA) and ISO 10180 (SPDL) are: stationery Separately cut sheets of an opaque material transparency Separately cut sheets of a transparent material envelope Envelopes that can be used for conventional mailing purposes envelope-plain Envelopes that are not preprinted and have no windows envelope-window Envelopes that have windows for addressing purposes continuous-long Continuously connected sheets of an opaque material connected along the long edge continuous-short Continuously connected sheets of an opaque material connected along the short edge tab-stock Media with tabs multi-part-form Form medium composed of multiple layers not pre-attached to one another; each sheet may be drawn separately from an input source labels Label stock multi-layer Form medium composed of multiple layers which are pre-attached to one another; e.g., for use with impact printers" ::= { prtInputEntry 21 } prtInputMediaColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the color of the medium associated with this input sub-unit using standardized string values from ISO 10175 (DPA) and ISO 10180 (SPDL) which are: other unknown white pink yellow buff goldenrod blue green transparent Implementors may add additional string values. The naming conventions in ISO 9070 are recommended in order to avoid potential name clashes." ::= { prtInputEntry 22 } prtInputMediaFormParts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of parts associated with the medium associated with this input sub-unit if the medium is a multi-part form. The value (-1) means other and specifically indicates that the device places no restrictions on this parameter. The value (-2) means unknown." ::= { prtInputEntry 23 } -- The Output Group -- -- Output sub-units are managed as a tabular, indexed collection of -- possible devices capable of receiving media delivered from the -- printing process. Output sub-units typically have a location, -- a type, an identifier, a set of constraints on possible media -- sizes and potentially other characteristics, and may be capable -- of indicating current status or capacity. -- -- Implementation of every object in this group is mandatory. prtOutput OBJECT IDENTIFIER ::= { printmib 9 } prtOutputDefaultIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtOutputIndex corresponding to the default output sub-unit; that is, this object selects the default output destination." ::= { prtGeneralEntry 7 } prtOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the devices capable of receiving media delivered from the printing process." ::= { prtOutput 2 } prtOutputEntry OBJECT-TYPE SYNTAX PrtOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Attributes of a device capable of receiving media delivered from the printing process. Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtOutputIndex } ::= { prtOutputTable 1 } PrtOutputEntry ::= SEQUENCE { prtOutputIndex Integer32, prtOutputType INTEGER, prtOutputCapacityUnit CapacityUnit, prtOutputMaxCapacity Integer32, prtOutputRemainingCapacity Integer32, prtOutputStatus SubUnitStatus, prtOutputName OCTET STRING, prtOutputVendorName OCTET STRING, prtOutputModel OCTET STRING, prtOutputVersion OCTET STRING, prtOutputSerialNumber OCTET STRING, prtOutputDescription OCTET STRING, prtOutputSecurity PresentOnOff, prtOutputDimUnit MediaUnit, prtOutputMaxDimFeedDir Integer32, prtOutputMaxDimXFeedDir Integer32, prtOutputMinDimFeedDir Integer32, prtOutputMinDimXFeedDir Integer32, prtOutputStackingOrder INTEGER, prtOutputPageDeliveryOrientation INTEGER, prtOutputBursting PresentOnOff, prtOutputDecollating PresentOnOff, prtOutputPageCollated PresentOnOff, prtOutputOffsetStacking PresentOnOff } prtOutputIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by this printer to identify this output sub-unit. Although these values may change due to a major reconfiguration of the sub-unit (e.g. the addition of new output devices to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtOutputEntry 1 } prtOutputType OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX INTEGER { other(1), unknown(2), removableBin(3), unRemovableBin(4), continuousRollDevice(5), mailBox(6), continuousFanFold(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of technology supported by this output sub-unit." ::= { prtOutputEntry 2 } prtOutputCapacityUnit OBJECT-TYPE SYNTAX CapacityUnit MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measurement for use in calculating and relaying capacity values for this output sub-unit." ::= { prtOutputEntry 3 } prtOutputMaxCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum capacity of this output sub-unit in output sub-unit capacity units (CapacityUnit). There is no convention associated with the media itself so this value essentially reflects claimed capacity. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be written (by a Remote Contol Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown." ::= { prtOutputEntry 4 } prtOutputRemainingCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The remaining capacity of the possible output sub-unit capacity in output sub-unit capacity units (CapacityUnit) of this output sub-unit. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be modified by management requests; otherwise, the value may be written (by a Remote Contol Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. The value (-3) means that the printer knows that there remains capacity for at least one unit." ::= { prtOutputEntry 5 } prtOutputStatus OBJECT-TYPE SYNTAX SubUnitStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of this output sub-unit." ::= { prtOutputEntry 6 } -- OUTPUT MEASUREMENT -- -- _______ | | _______ -- ^ | | ^ -- | | | | -- | | | RemainingCapacity -- MaxCapacity | | | -- | | | v ^ -- | |_ _ _ _ _ _ _ _ _ _ _| ___________________ |direction -- | | | | -- | | Sheets in output | -- v | | -- _______ +_____________________+ -- The Extended Output Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtOutputName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name assigned to this output sub-unit." ::= { prtOutputEntry 7 } prtOutputVendorName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor name of this output sub-unit." ::= { prtOutputEntry 8 } prtOutputModel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name assigned to this output sub-unit." ::= { prtOutputEntry 9 } prtOutputVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of this output sub-unit." ::= { prtOutputEntry 10 } prtOutputSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number assigned to this output sub-unit." ::= { prtOutputEntry 11 } prtOutputDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION " A free-form text description of this output sub-unit in the localization specified by prtGeneralCurrentLocalization." ::= { prtOutputEntry 12 } prtOutputSecurity OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if this output sub-unit has some security associated with it and if that security is enabled or not." ::= { prtOutputEntry 13 } -- The Output Dimensions Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtOutputDimUnit OBJECT-TYPE SYNTAX MediaUnit MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measurement for use in calculating and relaying dimensional values for this output sub-unit." ::= { prtOutputEntry 14 } prtOutputMaxDimFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum dimensions supported by this output sub-unit for measurements taken parallel relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations." ::= { prtOutputEntry 15 } prtOutputMaxDimXFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum dimensions supported by this output sub-unit for measurements taken ninety degrees relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations." ::= { prtOutputEntry 16 } prtOutputMinDimFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum dimensions supported by this output sub-unit for measurements taken parallel relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations." ::= { prtOutputEntry 17 } prtOutputMinDimXFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum dimensions supported by this output sub-unit for measurements taken ninety degrees relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed with management protocol operations." ::= { prtOutputEntry 18 } -- The Output Features Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtOutputStackingOrder OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { unknown(2), firstToLast(3), lastToFirst(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The current state of the stacking order for the associated output sub-unit. `FirstToLast' means that as pages are output the front of the next page is placed against the back of the previous page. `LasttoFirst' means that as pages are output the back of the next page is placed against the front of the previous page." ::= { prtOutputEntry 19 } prtOutputPageDeliveryOrientation OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { faceUp(3), faceDown(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The reading surface that will be `up' when pages are delivered to the associated output sub-unit. Values are Face-Up and Face-Down. (Note: interpretation of these values is in general context-dependent based on locale; presentation of these values to an end-user should be normalized to the expectations of the user)." ::= { prtOutputEntry 20 } prtOutputBursting OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates that the outputing sub-unit supports bursting, and if so, whether the feature is enabled. Bursting is the process by which continuous media is separated into individual sheets, typically by bursting along pre-formed perforations." ::= { prtOutputEntry 21 } prtOutputDecollating OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates that the output supports supports decollating, and if so, whether the feature is enabled. Decollating is the process by which the individual parts within a multi-part form are separated and sorted into separate stacks for each part." ::= { prtOutputEntry 22 } prtOutputPageCollated OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates that the output sub-unit supports page collation, and if so, whether the feature is enabled." ::= { prtOutputEntry 23 } prtOutputOffsetStacking OBJECT-TYPE SYNTAX PresentOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates that the output supports supports offset stacking, and if so, whether the feature is enabled." ::= { prtOutputEntry 24 } -- The Marker Group -- -- A marker is the mechanism that produces marks on the print media. The -- marker sub-units and their associated supplies are represented by the -- Marker Group in the model. A printer can contain one or more marking -- mechanisms. Some examples of multiple marker sub-units are: a printer -- with separate markers for normal and magnetic ink or an imagesetter -- that can output to both a proofing device and final film. Each marking -- device can have its own set of characteristics associated with it, -- such as marking technology and resolution. -- -- Implementation of every object in this group is mandatory. prtMarker OBJECT IDENTIFIER ::= { printmib 10 } prtMarkerDefaultIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtMarkerIndex corresponding to the default markersub-unit; that is, this object selects the default marker." ::= { prtGeneralEntry 8 } -- The printable area margins as listed below define an area of the print -- media which is guaranteed to be printable for all combinations of -- input, media paths, and interpreters for this marker. prtMarkerTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMarkerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtMarker 2 } prtMarkerEntry OBJECT-TYPE SYNTAX PrtMarkerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtMarkerIndex } ::= { prtMarkerTable 1 } PrtMarkerEntry ::= SEQUENCE { prtMarkerIndex Integer32, prtMarkerMarkTech INTEGER, prtMarkerCounterUnit INTEGER, prtMarkerLifeCount Counter32, prtMarkerPowerOnCount Counter32, prtMarkerProcessColorants Integer32, prtMarkerSpotColorants Integer32, prtMarkerAddressabilityUnit INTEGER, prtMarkerAddressabilityFeedDir Integer32, prtMarkerAddressabilityXFeedDir Integer32, prtMarkerNorthMargin Integer32, prtMarkerSouthMargin Integer32, prtMarkerWestMargin Integer32, prtMarkerEastMargin Integer32, prtMarkerStatus SubUnitStatus } prtMarkerIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this marking SubUnitStatus. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new marking sub-units to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtMarkerEntry 1 } prtMarkerMarkTech OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX INTEGER { other(1), unknown(2), electrophotographicLED(3), electrophotographicLaser(4), electrophotographicOther(5), impactMovingHeadDotMatrix9pin(6), impactMovingHeadDotMatrix24pin(7), impactMovingHeadDotMatrixOther(8), impactMovingHeadFullyFormed(9), impactBand(10), impactOther(11), inkjetAqueous(12), inkjetSolid(13), inkjetOther(14), pen(15), thermalTransfer(16), thermalSensitive(17), thermalDiffusion(18), thermalOther(19), electroerosion(20), electrostatic(21), photographicMicrofiche(22), photographicImagesetter(23), photographicOther(24), ionDeposition(25), eBeam(26), typesetter(27) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of marking technology used for this marking sub-unit." ::= { prtMarkerEntry 2 } prtMarkerCounterUnit OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4), characters(5), lines(6), impressions(7), sheets(8), dotRow(9), hours(11), feet(16), meters(17) } MAX-ACCESS read-only STATUS current DESCRIPTION "The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are provided for a device like a strip recorder that does not or cannot track the physical dimensions of the media and does not use characters, lines or sheets." ::= { prtMarkerEntry 3} prtMarkerLifeCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of the number of units of measure counted during the life of printer using units of measure as specified by CounterUnit." ::= { prtMarkerEntry 4 } prtMarkerPowerOnCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of the number of units of measure counted since the equipment was most recently powered on using units of measure as specified by CounterUnit." ::= { prtMarkerEntry 5 } prtMarkerProcessColorants OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of process colors supported by this marker. A process color of 1 implies monochrome. The value of this object and SpotColorants cannot both be 0. Must be 0 or greater." ::= { prtMarkerEntry 6 } prtMarkerSpotColorants OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of spot colors supported by this marker. The value of this object and ProcessColorants cannot both be 0. Must be 0 or greater." ::= { prtMarkerEntry 7 } prtMarkerAddressabilityUnit OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measure of distances." ::= { prtMarkerEntry 8 } prtMarkerAddressabilityFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of addressable marking positions in the feed direction per 10000 units of measure specified by AddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'." ::= { prtMarkerEntry 9 } prtMarkerAddressabilityXFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of addressable marking positions in the cross feed direction in 10000 units of measure specified by AddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'." ::= { prtMarkerEntry 10 } prtMarkerNorthMargin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The margin, in units identified by AddressabilityUnit, from the leading edge of the medium as the medium flows throught the marking engine with the side to be imaged facing the observer. The leading edge is the North edge and the other edges are defined by the normal compass layout of directions with the compass facing the observer. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown." ::= { prtMarkerEntry 11 } prtMarkerSouthMargin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The margin from the South edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown." ::= { prtMarkerEntry 12 } prtMarkerWestMargin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The margin from the West edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bouned by all four margins is guaranteed for all interpreters. The value (-2) means unknown." ::= { prtMarkerEntry 13 } prtMarkerEastMargin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The margin from the East edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown." ::= { prtMarkerEntry 14 } prtMarkerStatus OBJECT-TYPE SYNTAX SubUnitStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of this marker sub-unit." ::= { prtMarkerEntry 15 } prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 } prtMarkerSuppliesTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMarkerSuppliesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the marker supplies available on this printer." ::= { prtMarkerSupplies 1 } prtMarkerSuppliesEntry OBJECT-TYPE SYNTAX PrtMarkerSuppliesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Attributes of a marker supply. Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtMarkerSuppliesIndex } ::= { prtMarkerSuppliesTable 1 } PrtMarkerSuppliesEntry ::= SEQUENCE { prtMarkerSuppliesIndex Integer32, prtMarkerSuppliesMarkerIndex Integer32, prtMarkerSuppliesColorantIndex Integer32, prtMarkerSuppliesClass INTEGER, prtMarkerSuppliesType INTEGER, prtMarkerSuppliesDescription OCTET STRING, prtMarkerSuppliesSupplyUnit INTEGER, prtMarkerSuppliesMaxCapacity Integer32, prtMarkerSuppliesLevel Integer32 } prtMarkerSuppliesIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this marker supply. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new marker supplies to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtMarkerSuppliesEntry 1 } prtMarkerSuppliesMarkerIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of prtMarkerIndex corresponding to the marking sub-unit with which this marker supply sub-unit is associated." ::= { prtMarkerSuppliesEntry 2 } prtMarkerSuppliesColorantIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of prtMarkerColorantIndex corresponding to the colorant with which this marker supply sub-unit is associated. This value shall be 0 if there is no colorant table." ::= { prtMarkerSuppliesEntry 3 } prtMarkerSuppliesClass OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { other(1), supplyThatIsConsumed(3), receptacleThatIsFilled(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether this supply entity represents a supply container that is consumed or a receptacle that is filled." ::= { prtMarkerSuppliesEntry 4 } prtMarkerSuppliesType OBJECT-TYPE -- This value is a type 3 enumeration SYNTAX INTEGER { other(1), unknown(2), toner(3), wasteToner(4), ink(5), inkCartridge(6), inkRibbon(7), wasteInk(8), opc(9), developer(10), fuserOil(11), solidWax(12), ribbonWax(13), wasteWax(14) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of this supply." ::= { prtMarkerSuppliesEntry 5 } prtMarkerSuppliesDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The description of this supply container/receptacle in the localization specified by prtGeneralCurrentLocalization." ::= { prtMarkerSuppliesEntry 6 } prtMarkerSuppliesSupplyUnit OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4), thousandthsOfOunces(12), tenthsOfGrams(13), hundrethsOfFluidOunces(14), tenthsOfMilliliters(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "Unit of this marker supply container/receptacle." ::= { prtMarkerSuppliesEntry 7 } prtMarkerSuppliesMaxCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum capacity of this supply container/receptacle expressed in SupplyUnit. If this supply container/receptacle can reliably sense this value, the value is sensed by the printer and is read-only; otherwise, the value may be written (by a Remote Contol Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown." ::= { prtMarkerSuppliesEntry 8 } prtMarkerSuppliesLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The current level if this supply is a container; the remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is sensed by the printer and is read-only; otherwise, the value may be written (by a Remote Contol Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. A value of (-3) means that the printer knows that there is some supply/remaining space, respectively." ::= { prtMarkerSuppliesEntry 9 } -- The Marker Colorant Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 } prtMarkerColorantTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMarkerColorantEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of all of the colorants available on the printer." ::= { prtMarkerColorant 1 } prtMarkerColorantEntry OBJECT-TYPE SYNTAX PrtMarkerColorantEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Attributes of a colorant available on the printer. Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtMarkerColorantIndex } ::= { prtMarkerColorantTable 1 } PrtMarkerColorantEntry ::= SEQUENCE { prtMarkerColorantIndex Integer32, prtMarkerColorantMarkerIndex Integer32, prtMarkerColorantRole INTEGER, prtMarkerColorantValue OCTET STRING, prtMarkerColorantTonality Integer32 } prtMarkerColorantIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this colorant. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new colorants to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtMarkerColorantEntry 1 } prtMarkerColorantMarkerIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of prtMarkerIndex corresponding to the marker sub-unit with which this colorant entry is associated." ::= { prtMarkerColorantEntry 2 } prtMarkerColorantRole OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { -- Colorant Role other(1), process(3), spot(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The role played by this colorant." ::= { prtMarkerColorantEntry 3 } prtMarkerColorantValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the color of this The name of the color of this colorant using standardized string names from ISO 10175 (DPA) and ISO 10180 (SPDL) which are: other unknown white red green blue cyan magenta yellow black Implementors may add additional string values. The naming conventions in ISO 9070 are recommended in order to avoid potential name clashes" ::= { prtMarkerColorantEntry 4 } prtMarkerColorantTonality OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The distinct levels of tonality realizable by a marking sub-unit when using this colorant. This value does not include the number of levels of tonal difference that an interpreter can obtain by techniques such as half toning. This value must be at least 2." ::= { prtMarkerColorantEntry 5 } -- The Media Path Group -- -- The media paths encompass the mechanisms in the printer that move the -- media through the printer and connect all other media related sub- -- units: inputs, outputs, markers and finishers. A printer contains one -- or more media paths. These are represented by the Media Path Group in -- the model. The Media Path group has some attributes that apply to all -- paths plus a table of the separate media paths. prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 } prtMediaPathDefaultIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtMediaPathIndex corresponding to the default media path; that is, the selection of the default media path." ::= { prtGeneralEntry 9 } prtMediaPathTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMediaPathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtMediaPath 4 } prtMediaPathEntry OBJECT-TYPE SYNTAX PrtMediaPathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtMediaPathIndex } ::= { prtMediaPathTable 1 } PrtMediaPathEntry ::= SEQUENCE { prtMediaPathIndex Integer32, prtMediaPathMaxSpeedPrintUnit INTEGER, prtMediaPathMediaSizeUnit MediaUnit, prtMediaPathMaxSpeed Integer32, prtMediaPathMaxMediaFeedDir Integer32, prtMediaPathMaxMediaXFeedDir Integer32, prtMediaPathMinMediaFeedDir Integer32, prtMediaPathMinMediaXFeedDir Integer32, prtMediaPathType INTEGER, prtMediaPathDescription OCTET STRING, prtMediaPathStatus SubUnitStatus } prtMediaPathIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this media path. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new media paths to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtMediaPathEntry 1 } prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { tenThousandthsOfInchesPerHour(3), -- .0001/hour micrometersPerHour(4), charactersPerHour(5), linesPerHour(6), impressionsPerHour(7), sheetsPerHour(8), dotRowPerHour(9), feetPerHour(16), metersPerHour(17) } MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of measure used in specifying the speed of all media paths in the printer." ::= { prtMediaPathEntry 2 } prtMediaPathMediaSizeUnit OBJECT-TYPE SYNTAX MediaUnit MAX-ACCESS read-only STATUS current DESCRIPTION "The units of measure of media size for use in calculating and relaying dimensional values for all media paths in the printer." ::= { prtMediaPathEntry 3 } prtMediaPathMaxSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum printing speed of this media path expressed in prtMediaPathMaxSpeedUnit's. A value of (-1) implies 'other'." ::= { prtMediaPathEntry 4 } prtMediaPathMaxMediaFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum physical media size in the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-1) implies 'unlimited'. A value of (-2) implies 'unknown'" ::= { prtMediaPathEntry 5 } prtMediaPathMaxMediaXFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum physical media size across the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies 'unknown'." ::= { prtMediaPathEntry 6 } prtMediaPathMinMediaFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum physical media size in the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies 'unknown'." ::= { prtMediaPathEntry 7 } prtMediaPathMinMediaXFeedDir OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum physical media size across the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies 'unknown'." ::= { prtMediaPathEntry 8 } prtMediaPathType OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX INTEGER { other(1), unknown(2), longEdgeBindingDuplex(3), shortEdgeBindingDuplex(4), simplex(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the media path for this media path." ::= { prtMediaPathEntry 9 } prtMediaPathDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The manufacturer-provided description of this media path in the localization specified by prtGeneralCurrentLocalization." ::= { prtMediaPathEntry 10 } prtMediaPathStatus OBJECT-TYPE SYNTAX SubUnitStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of this media path." ::= { prtMediaPathEntry 11 } -- The Channel Group -- -- Implementation of every object in this group is mandatory. -- Channels are independent sources of print data. Here, -- print data is the term used for the information that is -- used to construct printed pages and may have both data -- and control aspects. The output of a channel is in a form -- suitable for input to one of the interpreters as a -- stream. A channel may be independently enabled (allowing -- print data to flow) or disabled (stopping the flow of -- print data). A printer may have one or more channels. -- -- Basically, the channel abstraction is intended to cover -- all the aspects of getting the print data to an -- interpreter. This might include transporting the data -- from one place to another, it might include (invisible) -- compression, it might include encoding or packetizing to -- provide multiple information sources over a single -- physical interface and it might include filtering -- characters that were destined for another kind of -- channel. All of these aspects are hidden in the channel -- abstraction.(Note some Page Description Languages have -- compression built into them so "invisible" compression -- refers to compression done by the transport medium and -- removed before the data is presented to the interpreter.) -- -- There are many kinds of channels;some of which are based -- on networks and others which are not. For example, a -- channel can be a serial (or parallel) connection; it can -- be a service, such as the Unix Line Printer Daemon (LPD), -- offering itself over a network connection (interface); or -- it could be a disk drive into which a floppy disks with -- the print data is inserted. Each channel is typically -- identified by the electronic path and/or service protocol -- used to deliver print data to the printer. -- -- Channel example Implementation -- -- serial port channel bi-directional data channel -- parallel port channel often uni-directional channel -- IEEE 1284 port channel bi-directional channel -- SCSI port channel bi-directional -- Apple PAP channel may be based on Local-, Ether-or -- TokenTalk -- LPD Server channel typically TCP/IP based, port 515 -- Novell Remote Printer typically SPX/IPX based channel -- Novell Print Server typically SPX/IPX based channel -- port 9100 channel HP and friends -- Adobe AppSocket(9101) channel a bi-directional extension of LPD -- -- It is easy to note that this is a mixed bag. There are -- some physical connections over which no (or very meager) -- protocols are run (e.g. the serial or old parallel ports) -- and there are services which often have elaborate -- protocols that run over a number of protocol stacks. In -- the end what is important is the delivery of print data -- thru the channel. -- -- The channel sub-units are represented by the Channel -- Group in the Model. It has a current Control Language -- which can be used to specify which interpreter is to be -- used for the print data and to query and change -- environment variables used by the interpreters (and -- Mangement Applications). There is also a default -- interpreter that is to be used if an interpreter is not -- explicitly specified using the Control Language. Channel -- sub-units are based on an underlying interface. -- The channel table and its underlying structure -- -- The first seven items in the Channel Table define the -- "channel" itself. A channel typically depends on other -- protocols and interfaces to provide the data that flows -- thru the channel. It is necessary to provide control of -- the (perhaps complex) process by which print data arrives -- at an interpreter. Control is largely limited to enabling -- or disabling the whole channel. It is likely, however, -- that more control of the process of accessing print data -- will be needed over time. Thus, the ChannelType will -- allow type specific data to be associated with each -- channel (using ChannelType specific groups in a fashion -- analogous to the media specific MIBs that are associated -- with the IANAIfType in the Interfaces Table). As a first -- step in this direction, each channel will identify the -- underlying Interface on which it is based. This is the -- eighth object in each row of the table. -- Some examples of the kind of control are where -- compression or encoding is used; and whether the data is -- filtered to remove file storage anomolies such as those -- created by using MS-DOS/PC-DOS LPT1:. -- -- The Channel Table -- -- The prtChannelTable represents the set of input data sources which -- can provide print data to one or more of the interpreters -- available on a printer prtChannel OBJECT IDENTIFIER ::= { printmib 14 } prtChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtChannel 1 } prtChannelEntry OBJECT-TYPE SYNTAX PrtChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtChannelIndex } ::= { prtChannelTable 1 } PrtChannelEntry ::= SEQUENCE { prtChannelIndex Integer32, prtChannelType INTEGER, prtChannelProtocolVersion OCTET STRING, prtChannelCurrentJobCntlLangIndex Integer32, prtChannelDefaultPageDescLangIndex Integer32, prtChannelState INTEGER, prtChannelIfIndex Integer32, prtChannelStatus SubUnitStatus } prtChannelIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this data channel. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new data channels to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtChannelEntry 1 } prtChannelType OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX INTEGER { other(1), chSerialPort(3), chParallelPort(4), chIEEE1284Port(5), chSCSIPort(6), chAppleTalkPAP(7), -- AppleTalk Printer Achess Protocol chLPDServer(8), chNetwareRPrinter(9), -- Netware chNetwarePServer(10), -- Netware chPort9100(11), chAppSocket(12), -- a bi-directional, LPD-like -- protocol using 9101 for -- control and 9100 for data. -- Adobe Systems, Inc. chFTP(13), -- FTP "PUT" to printer chTFTP(14), chDLCLLCPort(15), chIBM3270(16), chIBM5250(17), chFax(18), chIEEE1394(19), chTransport1(20), -- port 35 chCPAP(21), -- port 170 chDCERemoteProcCall(22), -- OSF chONCRemoteProcCall(23), -- Sun Microsystems chOLE(24), -- Microsoft chNamedPipe(25), chPCPrint(26), -- Banyan chServerMessageBlock(27), -- File/Print sharing protocol used by -- various network operating systems -- from IBM 3Com, Microsoft and others chDPMF(28), -- Distributed Print Mgt. Framework, IBM chDLLAPI(29), -- Microsoft chVxDAPI(30), -- Microsoft chSystemObjectManager(31), -- IBM chDECLAT(32), -- Digital Equipment Corp. chNPAP(33) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of this print data channel. This object provides the linkage to ChannelType-specific groups that may (conceptually) extend the prtChannelTable with additional details about that channel." ::= { prtChannelEntry 2 } prtChannelProtocolVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the protocol used on this channel. The format used for version numbering depends on prtChannelType." ::= { prtChannelEntry 3 } prtChannelCurrentJobCntlLangIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtInterpreterIndex corresponding to the Control Language Interpreter for this channel. This interpreter defines the syntax used for control functions, such as querying or changing environment variables and identifying job boundaries (e.g. PJL, PostScript, NPAP). Must be 1 or greater." ::= { prtChannelEntry 4 } prtChannelDefaultPageDescLangIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of prtInterpreterIndex corresponding to the Page Description Language Interpreter for this channel. This interpreter defines the default Page Description Language interpreter to be used for the print data unless the Control Language is used to select a specific interpreter (e.g., PCL, PostScript Language, auto-sense). Must be 1 or greater." ::= { prtChannelEntry 5 } prtChannelState OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { other(1), printDataAccepted(3), noDataAccepted(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The state of this print data channel. The value determines whether control information and print data is allowed through this channel or not." ::= { prtChannelEntry 6 } prtChannelIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of ifIndex (in the ifTable; see the interface section of MIB-2/RFC 1213) which corresponds to this channel. When more than one row of the ifTable is relevant, this is the index of the row representing the topmost layer in the interface hierarchy. A value of zero indicates that no interface is associated with this channel." ::= { prtChannelEntry 7 } prtChannelStatus OBJECT-TYPE SYNTAX SubUnitStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the channel." ::= { prtChannelEntry 8 } -- The Interpreter Group -- -- The interpreter sub-units are responsible for the conversion of a -- description of intended print instances into images that are to be -- marked on the media. A printer may have one or more interpreters. The -- interpreter sub-units are represented by the Interpreter Group in the -- Model. Each interpreter is generally implemented with software running -- on the System Controller sub-unit. The Interpreter Table has one entry -- per interpreter where the interpreters include both Page Description -- Language (PDL) Interpreters and Control Language Interpreters. -- -- Implementation of every object in this group is mandatory. prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 } -- Interpreter Table -- -- The prtInterpreterTable is a table representing the interpreters in -- the printer. An entry shall be placed in the interpreter table for -- each interpreter on the printer. prtInterpreterTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInterpreterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtInterpreter 1 } prtInterpreterEntry OBJECT-TYPE SYNTAX PrtInterpreterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtInterpreterIndex } ::= { prtInterpreterTable 1 } PrtInterpreterEntry ::= SEQUENCE { prtInterpreterIndex Integer32, prtInterpreterLangFamily INTEGER, prtInterpreterLangLevel OCTET STRING, prtInterpreterLangVersion OCTET STRING, prtInterpreterDescription OCTET STRING, prtInterpreterVersion OCTET STRING, prtInterpreterDefaultOrientation INTEGER, prtInterpreterFeedAddressability Integer32, prtInterpreterXFeedAddressability Integer32, prtInterpreterDefaultCharSetIn CodedCharSet, prtInterpreterDefaultCharSetOut CodedCharSet, prtInterpreterTwoWay INTEGER } prtInterpreterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value for each PDL or control language for which there exists an interpreter or emulator in the printer. The value is used to identify this interpreter. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new interpreters to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtInterpreterEntry 1 } prtInterpreterLangFamily OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX INTEGER { other(1), langPCL(3), -- PCL. Starting with PCL version 5, -- HP-GL/2 is included as part of the -- PCL language. -- PCL and HP-GL/2 are registered -- trademarks of Hewlett-Packard Company. langHPGL(4), -- Hewlett-Packard Graphics Language. -- HP-GL is a registered trademark of -- Hewlett-Packard Company. langPJL(5), -- Peripheral Job Language. Appears in the -- data stream between data intended for a -- page description language. -- Hewlett-Packard Co. langPS(6), -- PostScript Language (tm) -- Postscript - a trademark of Adobe -- Systems Incorporated which may be -- registered in certain jurisdictions langPSPrinter(42), -- The PostScript Language used for -- control (with any PDLs) -- Adobe Systems Incorporated langIPDS(7), -- Intelligent Printer Data Stream -- Bi-directional print data stream for -- documents consisting of data objects -- (text, image, graphics, bar codes), -- resources (fonts, overlays) and page, -- form and finishing instructions. -- Facilitates system level device -- control, document tracking and error -- recovery throughout the print process. -- Pennant Systems, IBM langPPDS(8), -- IBM Personal Printer Data Stream. -- Originally called IBM ASCII, the name -- was changed to PPDS when the Laser -- Printer was introduced in 1989. -- Lexmark International, Inc. langEscapeP(9), langEpson(10), langDDIF(11), -- Digital Document Interchange Format -- Digital Equipment Corp., Maynard MA langInterpress(12), langISO6429(13), -- ISO 6429. Control functions for Coded -- Character Sets (has ASCII control -- characters, plus additional controls for -- character imaging devices.) -- ISO Standard, Geneva, Switzerland langLineData(14), -- line-data: Lines of data as separate -- ASCII or EBCDIC records and containing -- no control functions (no CR, LF, HT, FF, -- etc.). For use with traditional line -- printers. May use CR and/or LF to -- delimit lines, instead of records. See -- ISO 10175 Document Printing Application -- (DPA) -- ISO standard, Geneva, Switzerland langMODCA(15), -- Mixed Object Document Content Architecture -- Definitions that allow the composition, -- interchange, and presentation of final -- form documents as a collection of data -- objects (text, image, graphics, bar -- codes), resources (fonts, overlays) and -- page, form and finishing instructions. -- Pennant Systems, IBM langREGIS(16), -- Remote Graphics Instruction Set, -- Digital Equipment Corp., Maynard MA langSCS(17), -- SNA Character String -- Bi-directional print data stream for SNA -- LU-1 mode of communications -- IBM langSPDL(18), -- ISO 10180 Standard Page Description -- Language -- ISO Standard langTEK4014(19), langPDS(20), langIGP(21), langCodeV(22), -- Magnum Code-V, Image and printer control -- language used to control impact/dot- -- matrix printers. -- QMS, Inc., Mobile AL langDSCDSE(23), -- DSC-DSE: Data Stream Compatible and -- Emulation Bi-directional print data -- stream for non-SNA (DSC) and SNA LU-3 -- 3270 controller (DSE) communications -- IBM langWPS(24), -- Windows Printing System, Resource based -- command/data stream used by Microsoft At -- Work Peripherals. -- Developed by the Microsoft Corporation. langLN03(25), -- Early DEC-PPL3, Digital Equipment Corp. langCCITT(26), langQUIC(27), -- QUIC (Quality Information Code), Page -- Description Language for laser printers. -- Included graphics, printer control -- capability and emulation of other well- -- known printer . -- QMS, Inc. langCPAP(28), -- Common Printer Access Protocol -- Digital Equipment Corp. langDecPPL(29), -- Digital ANSI-Compliant Printing Protocol -- (DEC-PPL) -- Digital Equipment Corp. langSimpleText(30),-- simple-text: character coded data, -- including NUL, CR , LF, HT, and FF -- control characters. See ISO 10175 -- Document Printing Application (DPA) -- ISO standard, Geneva, Switzerland langNPAP(31), -- Network Printer Alliance Protocol -- IEEE 1284.1 langDOC(32), -- Document Option Commands, Appears in the -- data stream between data intended for a -- page description . -- QMS, Inc. langimPress(33), -- imPRESS, Page description language -- originally developed for the ImageServer -- line of systems. A binary language -- providing representations for text, -- simple graphics (rules, lines, conic -- sections), and some large forms (simple -- bit-map and CCITT group 3/4 encoded).The -- language was intended to be sent over an -- 8-bit channel and supported early -- document preparation languages (e.g. TeX -- and TROFF). -- QMS, Inc. langPinwriter(34), -- 24 wire dot matrix printer for -- USA, Europe, and Asia except Japan. -- More widely used in Germany, and some -- Asian countries than in US. -- NEC langNPDL(35), -- Page printer for Japanese -- market. -- NEC langNEC201PL(36), -- Serial printer language used in the -- Japanese market. -- NEC langAutomatic(37), -- Automatic PDL sensing. Automatic -- sensing of the interpreter language -- family by the printer examining the -- document content. Which actual -- interpreter language families are sensed -- depends on the printer implementation. langPages(38), -- Page printer Advanced Graphic Escape Set -- IBM Japan langLIPS(39), -- LBP Image Processing System langTIFF(40), -- Tagged Image File Format (Aldus) langDiagnostic(41),-- A hex dump of the input to the -- interpreter langCaPSL(43), -- Canon Print Systems Language langEXCL(44), -- Extended Command Language -- Talaris Systems Inc. langLCDS(45), -- Line Conditioned Data Stream -- Xerox Corporation langXES(46) -- Xerox Escape Sequences -- Xerox Corporation } MAX-ACCESS read-only STATUS current DESCRIPTION "The family name of a Page Description Language (PDL) or control language which this interpreter in the printer can interpret or emulate. This type 2 list of enumerations requires review before additional entries are made." ::= { prtInterpreterEntry 2 } prtInterpreterLangLevel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "The level of the language which this interpreter is interpreting or emulating. This might contain a value like '5e' for an interpreter which is emulating level 5e of the PCL language. It might contain '2' for an interpreter which is emulating level 2 of the PostScript language. Similarly it might contain '2' for an interpreter which is emulating level 2 of the HPGL language." ::= { prtInterpreterEntry 3 } prtInterpreterLangVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date code or version of the language which this interpreter is interpreting or emulating." ::= { prtInterpreterEntry 4 } prtInterpreterDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A string to identify this interpreter in the localization specified by prtGeneralCurrentLocalization as opposed to the language which is being interpreted. It is anticipated that this string will allow manufacturers to unambiguously identify their interpreters." ::= { prtInterpreterEntry 5 } prtInterpreterVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date code, version number, or other product specific information tied to this interpreter. This value is associated with the interpreter, rather than with the version of the language which is being interpreted or emulated." ::= { prtInterpreterEntry 6 } prtInterpreterDefaultOrientation OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { other(1), portrait(3), landscape(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The current orientation default for this interpreter. This value may be overridden for a particular job (e.g., by a command in the input data stream)." ::= { prtInterpreterEntry 7 } prtInterpreterFeedAddressability OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnit s (see prtMarkerAddressabilityFeedDir ) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter." ::= { prtInterpreterEntry 8 } prtInterpreterXFeedAddressability OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum interpreter addressability in the cross feed direction in 10000 prtMarkerAddressabilityUnit s (see prtMarkerAddressabilityXFeedDir) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter." ::= { prtInterpreterEntry 9 } prtInterpreterDefaultCharSetIn OBJECT-TYPE SYNTAX CodedCharSet MAX-ACCESS read-write STATUS current DESCRIPTION "The default coded character set for input octets encountered outside a context in which the Page Description Language established the interpretation of the octets. This value shall be (2) if there is no default." ::= { prtInterpreterEntry 10 } prtInterpreterDefaultCharSetOut OBJECT-TYPE SYNTAX CodedCharSet MAX-ACCESS read-write STATUS current DESCRIPTION "The default character set for data coming from this interpreter through the printer's output channel. This value shall be (2) if there is no default." ::= { prtInterpreterEntry 11 } prtInterpreterTwoWay OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { yes(3), no(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not this interpreter returns information back to the host." ::= { prtInterpreterEntry 12 } -- The Console Group -- -- Many printers have a console on the printer, the operator console, -- that is used to display and modify the state of the printer. The -- console can be as simple as a few indicators and switches or as -- complicated as full screen displays and keyboards. There can be -- at most one such console. -- -- Implementation of every object in this group is mandatory. prtConsoleLocalization OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the prtLocalizationIndex corresponding to the language, country, and character set to be used for the console. This localization applies both to the actual display on the console as well as the encoding of these console objects in management operations." ::= { prtGeneralEntry 10 } prtConsoleNumberOfDisplayLines OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of lines on the printer's physical display. This value is 0 if there are no lines on the physical display or if there is no physical display" ::= { prtGeneralEntry 11 } prtConsoleNumberOfDisplayChars OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of characters per line displayed on the physical display. This value is 0 if there are no lines on the physical display or if there is no physical display" ::= { prtGeneralEntry 12 } prtConsoleDisable OBJECT-TYPE SYNTAX INTEGER { enabled(3), disabled(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables or disables manual input from the operators console." ::= { prtGeneralEntry 13 } -- The Display Buffer Table prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 } prtConsoleDisplayBufferTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtConsoleDisplayBufferEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtConsoleDisplayBuffer 5 } prtConsoleDisplayBufferEntry OBJECT-TYPE SYNTAX PrtConsoleDisplayBufferEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one entry for each physical line on the display. Lines cannot be added or deleted. Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtConsoleDisplayBufferIndex } ::= { prtConsoleDisplayBufferTable 1 } PrtConsoleDisplayBufferEntry ::= SEQUENCE { prtConsoleDisplayBufferIndex Integer32, prtConsoleDisplayBufferText OCTET STRING } prtConsoleDisplayBufferIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value for each console line in the printer. The value is used to identify this console line. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new console lines to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtConsoleDisplayBufferEntry 1 } prtConsoleDisplayBufferText OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The content of a line in the logical display buffer of the operator's console of the printer. When a write operation occurs, normally a critical message, to one of the LineText strings, the agent should make that line displayable if a physical display is present. Writing a zero length string clears the line. It is an implementation-specific matter as to whether the agent allows a line to be overwritten before it has been cleared. Printer generated strings shall be in the localization specified by ConsoleLocalization. Management Application generated strings should be localized by the Management Application." ::= { prtConsoleDisplayBufferEntry 2 } -- The Console Light Table prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 } prtConsoleLightTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtConsoleLightEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtConsoleLights 6 } prtConsoleLightEntry OBJECT-TYPE SYNTAX PrtConsoleLightEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtConsoleLightIndex } ::= { prtConsoleLightTable 1 } PrtConsoleLightEntry ::= SEQUENCE { prtConsoleLightIndex Integer32, prtConsoleOnTime Integer32, prtConsoleOffTime Integer32, prtConsoleColor INTEGER, prtConsoleDescription OCTET STRING } prtConsoleLightIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value used by the printer to identify this light. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new lights to the printer), values are expected to remain stable across successive printer power cycles." ::= { prtConsoleLightEntry 1 } prtConsoleOnTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The on time in milliseconds of blinking of this light; 0 indicates off always. If both prtConsoleOnTime and prtConsoleOffTime are 0, then the light is always off." ::= { prtConsoleLightEntry 2 } prtConsoleOffTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The off time in milliseconds of blinking of this light; 0 indicates on always. If both prtConsoleOnTime and prtConsoleOffTime are 0, then the light is always off." ::= { prtConsoleLightEntry 3 } prtConsoleColor OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX INTEGER { other(1), unknown(2), white(3), red(4), green(5), blue(6), cyan(7), magenta(8), yellow(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The color of this light." ::= { prtConsoleLightEntry 4 } prtConsoleDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor description or label of this light in the localization specified by prtConsoleLocalization." ::= { prtConsoleLightEntry 5 } -- The Alerts Group -- -- The prtAlertTable lists all the critical and non-critical alerts -- currently active in the printer. A critical alert is one that stops -- the printer from printing immediately and printing can not continue -- until the critical alert condition is eliminated. Non-critical -- alerts are those items that do not stop printing but may at some -- future time. -- The table contains information on the severity, component, detail -- location within the component, alert code and description of each -- critical alert that is currently active within the printer. See -- 2.2.13 for a more complete description of the alerts table and -- its management. -- -- Implementation of every object in this group is mandatory. prtAlert OBJECT IDENTIFIER ::= { printmib 18 } prtAlertTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtAlertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { prtAlert 1 } prtAlertEntry OBJECT-TYPE SYNTAX PrtAlertEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries may exist in the table for each device index who's device type is `printer'." INDEX { hrDeviceIndex, prtAlertIndex } ::= { prtAlertTable 1 } PrtAlertEntry ::= SEQUENCE { prtAlertIndex Integer32, prtAlertSeverityLevel INTEGER, prtAlertTrainingLevel INTEGER, prtAlertGroup INTEGER, prtAlertGroupIndex Integer32, prtAlertLocation Integer32, prtAlertCode INTEGER, prtAlertDescription OCTET STRING, prtAlertTime TimeTicks } prtAlertIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index value used to determine which alerts have been added or removed from the alert table. This is an incrementing integer starting from zero every time the printer is reset. When the printer adds an alert to the table, that alert is assigned the next higher integer value from the last item entered into the table. If the index value reaches its maximum value, the next item entered will cause the index value to roll over and start at zero again. The first event placed in the alert table after a reset of the printer shall have an index value of 1. NOTE: The management application will read the alert table when a trap or event notification occurs or at a periodic rate and then parse the table to determine if any new entries were added by comparing the last known index value with the current highest index value. The management application will then update its copy of the alert table. When the printer discovers that an alert is no longer active, the printer shall remove the row for that alert from the table and shall reduce the number of rows in the table. The printer may add or delete any number of rows from the table at any time. The management station can detect when binary alerts have been deleted by requesting an attribute of each alert, and noting alerts as deleted when that retrieval is not possible." ::= { prtAlertEntry 1 } prtAlertSeverityLevel OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { other(1), critical(3), warning(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The level of severity of this alert table entry. The printer determines the severity level assigned to each entry into the table." ::= { prtAlertEntry 2 } prtAlertTrainingLevel OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX INTEGER { other(1), unknown(2), untrained(3), trained(4), fieldService(5), management(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The level of training required to handle this alert. The training level is an enumeration that is determined and assigned by the printer manufacturer based on the information or the training required to handle this alert. The printer will break alerts into these different training levels. It is the responsibility of the management application in the system to determine how a particular alert is handled and how and to whom that alert is routed. The following are the four training levels of alerts: Field Service - Alerts that typically require advanced training and technical knowledge of the printer and its sub-units. An example of a technical person would be a manufacture's Field Service representative, or other person formally trained by the manufacturer or similar representative. Trained - Alerts that require an intermediate or moderate level of knowledge of the printer and its sub-units. A typical examples of alerts that a trained operator can handle is replacing toner cartridges. Untrained - Alerts that can be fixed without prior training either because the action to correct the alert is obvious or the printer can help the untrained person fix the problem. A typical example of such an alert is reloading paper trays and emptying output bins on a low end printer. Management - Alerts that have to do with overall operation of and configuration of the printer. Examples of management events are configuration change of sub-units." ::= { prtAlertEntry 3 } prtAlertGroup OBJECT-TYPE -- This value is a type 1 enumeration SYNTAX INTEGER { other(1), hostResourcesMIBStorageTable(3), hostResourcesMIBDeviceTable(4), generalPrinter(5), cover(6), localization(7), input(8), output(9), marker(10), markerSupplies(11), markerColorant(12), mediaPath(13), channel(14), interpreter(15), consoleDisplayBuffer(16), consoleLights(17) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of sub-units. Whereever possible, these enumerations match the sub-identifier that identifies the relevant table in the printmib." ::= { prtAlertEntry 4 } prtAlertGroupIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index of the row within the principle table in the group identified by prtAlertGroup that represents the sub-unit of the printer that caused this alert. The combination of the Group and the GroupIndex defines exactly which printer sub-unit caused the alert.; for example, Input #3, Output #2, and Marker #1. Every object in this MIB is indexed with hrDeviceIndex and optionally, another index variable. If this other index variable is present in the table that generated the alert, it will be used as the value for this object. Otherwise, this value shall be -1." ::= { prtAlertEntry 5 } prtAlertLocation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designated sub-unit. The location is used in conjunction with the Group and GroupIndex values; for example, there is an alert in Input #2 at location number 7." ::= { prtAlertEntry 6 } prtAlertCode OBJECT-TYPE -- This value is a type 2 enumeration SYNTAX INTEGER { other(1), unknown(2), -- codes common to serveral groups coverOpen(3), coverClosed(4), interlockOpen(5), interlockClosed(6), configurationChange(7), jam(8), -- general Printer group doorOpen(501), doorClosed(502), powerUp(503), powerDown(504), -- Input Group inputMediaTrayMissing(801), inputMediaSizeChange(802), inputMediaWeightChange(803), inputMediaTypeChange(804), inputMediaColorChange(805), inputMediaFormPartsChange(806), inputMediaSupplyLow(807), inputMediaSupplyEmpty(808), -- Output Group outputMediaTrayMissing(901), outputMediaTrayAlmostFull(902), outputMediaTrayFull(903), -- Marker group markerFuserUnderTemperature(1001), markerFuserOverTemperature(1002), -- Marker Supplies group markerTonerEmpty(1101), markerInkEmpty(1102), markerPrintRibbonEmpty(1103), markerTonerAlmostEmpty(1104), markerInkAlmostEmpty(1105), markerPrintRibbonAlmostEmpty(1106), markerWasteTonerReceptacleAlmostFull(1107), markerWasteInkReceptacleAlmostFull(1108), markerWasteTonerReceptacleFull(1109), markerWasteInkReceptacleFull(1110), markerOpcLifeAlmostOver(1111), markerOpcLifeOver(1112), markerDeveloperAlmostEmpty(1113), markerDeveloperEmpty(1114), -- Media Path Device Group mediaPathMediaTrayMissing(1301), mediaPathMediaTrayAlmostFull(1302), mediaPathMediaTrayFull(1303), -- interpreter Group interpreterMemoryIncrease(1501), interpreterMemoryDecrease(1502), interpreterCartridgeAdded(1503), interpreterCartridgeDeleted(1504), interpreterResourceAdded(1505), interpreterResourceDeleted(1506), interpreterResourceUnavailable(1507) } MAX-ACCESS read-only STATUS current DESCRIPTION "The code that describes the type of alert for this entry in the table. There are different codes for each sub-unit type: for example, Media Supply Low and Media Supply Empty are Aler codes for the Input sub-unit." ::= { prtAlertEntry 7} prtAlertDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A description of this alert entry in the localization specified by prtGeneralCurrentLocalization. The description is provided by the printer to further elaborate on the enumerated alert or provide information in the case where the code is classified ask `other' or `unknown'. The printer is required to return a description string but the string may be a null string." ::= { prtAlertEntry 8 } printerV1Alert OBJECT-IDENTITY STATUS current DESCRIPTION "The value of the enterprise-specific oid in a SNMPv1 trap sent signalling a critical event in the prtAlertTable." ::= { prtAlert 2 } printerV2AlertPrefix OBJECT IDENTIFIER ::= { printerV1Alert 0 } printerV2Alert NOTIFICATION-TYPE OBJECTS { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, prtAlertCode } STATUS current DESCRIPTION "This trap is sent whenever a critical event is added to the prtAlertTable." ::= { printerV2AlertPrefix 1 } -- Note that the SNMPv2 to SNMPv1 translation rules dictate that the -- preceding structure will result in SNMPv1 traps of the following -- form: -- -- printerAlert TRAP-TYPE -- ENTERPRISE printerV1Alert -- VARIABLES { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup, -- prtAlertGroupIndex, prtAlertLocation, prtAlertCode } -- DESCRIPTION -- "This trap is sent whenever a critical event is added to the -- prtAlertTable." -- ::= 1 -- The Alert Time Group -- -- This group is optional. However, to claim conformance to this -- group, it is necessary to implement every object in the group. prtAlertTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time that this alert was generated." ::= { prtAlertEntry 9 } -- Conformance Information prtMIBConformance OBJECT IDENTIFIER ::= { printmib 2 } -- compliance statements prtMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for agents that implement the printer MIB." MODULE -- this module MANDATORY-GROUPS { prtGeneralGroup, prtInputGroup, prtOutputGroup, prtMarkerGroup, prtMediaPathGroup, prtChannelGroup, prtInterpreterGroup, prtConsoleGroup, prtAlertTableGroup } OBJECT prtGeneralReset SYNTAX INTEGER { notResetting(3), resetToNVRAM(5) } DESCRIPTION "It is conformant to implement just these two states in this object. Any additional states are optional." OBJECT prtConsoleOnTime MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only." OBJECT prtConsoleOffTime MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only." -- the prtResponsiblePartyGroup, prtExtendedInputGroup, -- prtInputMediaGroup, prtExtendedOutputGroup, -- prtOutputDimensionsGroup, prtOutputFeaturesGroup, -- prtMarkerSuppliesGroup, prtMarkerColorantGroup, -- and the prtAlertTimeGroup are completely optional. ::= { prtMIBConformance 1 } prtMIBGroups OBJECT IDENTIFIER ::= { prtMIBConformance 2 } prtGeneralGroup OBJECT-GROUP OBJECTS { prtGeneralConfigChanges, prtGeneralCurrentLocalization, prtGeneralReset, prtCoverDescription, prtCoverStatus, prtLocalizationLanguage, prtLocalizationCountry, prtLocalizationCharacterSet, prtStorageRefIndex, prtDeviceRefIndex } STATUS current DESCRIPTION "The general printer group." ::= { prtMIBGroups 1 } prtResponsiblePartyGroup OBJECT-GROUP OBJECTS { prtGeneralCurrentOperator, prtGeneralServicePerson } STATUS current DESCRIPTION "The responsible party group contains contact information for humans responsible for the printer." ::= { prtMIBGroups 2 } prtInputGroup OBJECT-GROUP OBJECTS { prtInputDefaultIndex, prtInputType, prtInputDimUnit, prtInputMediaDimFeedDirDeclared, prtInputMediaDimXFeedDirDeclared, prtInputMediaDimFeedDirChosen, prtInputMediaDimXFeedDirChosen, prtInputCapacityUnit, prtInputMaxCapacity, prtInputCurrentLevel, prtInputStatus, prtInputMediaName } STATUS current DESCRIPTION "The input group." ::= { prtMIBGroups 3 } prtExtendedInputGroup OBJECT-GROUP OBJECTS { prtInputName, prtInputVendorName, prtInputModel, prtInputVersion, prtInputSerialNumber, prtInputDescription, prtInputSecurity } STATUS current DESCRIPTION "The extended input group." ::= { prtMIBGroups 4 } prtInputMediaGroup OBJECT-GROUP OBJECTS { prtInputMediaWeight, prtInputMediaType, prtInputMediaColor, prtInputMediaFormParts } STATUS current DESCRIPTION "The input media group." ::= { prtMIBGroups 5 } prtOutputGroup OBJECT-GROUP OBJECTS { prtOutputDefaultIndex, prtOutputType, prtOutputCapacityUnit, prtOutputMaxCapacity, prtOutputRemainingCapacity, prtOutputStatus } STATUS current DESCRIPTION "The output group." ::= { prtMIBGroups 6 } prtExtendedOutputGroup OBJECT-GROUP OBJECTS { prtOutputName, prtOutputVendorName, prtOutputModel, prtOutputVersion, prtOutputSerialNumber, prtOutputDescription, prtOutputSecurity } STATUS current DESCRIPTION "The extended output group." ::= { prtMIBGroups 7 } prtOutputDimensionsGroup OBJECT-GROUP OBJECTS { prtOutputDimUnit, prtOutputMaxDimFeedDir, prtOutputMaxDimXFeedDir, prtOutputMinDimFeedDir, prtOutputMinDimXFeedDir } STATUS current DESCRIPTION "The output dimensions group" ::= { prtMIBGroups 8 } prtOutputFeaturesGroup OBJECT-GROUP OBJECTS { prtOutputStackingOrder, prtOutputPageDeliveryOrientation, prtOutputBursting, prtOutputDecollating, prtOutputPageCollated, prtOutputOffsetStacking } STATUS current DESCRIPTION "The output features group." ::= { prtMIBGroups 9 } prtMarkerGroup OBJECT-GROUP OBJECTS { prtMarkerDefaultIndex, prtMarkerMarkTech, prtMarkerCounterUnit, prtMarkerLifeCount, prtMarkerPowerOnCount, prtMarkerProcessColorants, prtMarkerSpotColorants, prtMarkerAddressabilityUnit, prtMarkerAddressabilityFeedDir, prtMarkerAddressabilityXFeedDir, prtMarkerNorthMargin, prtMarkerSouthMargin, prtMarkerWestMargin, prtMarkerEastMargin, prtMarkerStatus } STATUS current DESCRIPTION "The marker group." ::= { prtMIBGroups 10 } prtMarkerSuppliesGroup OBJECT-GROUP OBJECTS { prtMarkerSuppliesMarkerIndex, prtMarkerSuppliesColorantIndex, prtMarkerSuppliesClass, prtMarkerSuppliesType, prtMarkerSuppliesDescription, prtMarkerSuppliesSupplyUnit, prtMarkerSuppliesMaxCapacity, prtMarkerSuppliesLevel } STATUS current DESCRIPTION "The marker supplies group." ::= { prtMIBGroups 11 } prtMarkerColorantGroup OBJECT-GROUP OBJECTS { prtMarkerColorantMarkerIndex, prtMarkerColorantRole, prtMarkerColorantValue, prtMarkerColorantTonality } STATUS current DESCRIPTION "The marker colorant group." ::= { prtMIBGroups 12 } prtMediaPathGroup OBJECT-GROUP OBJECTS { prtMediaPathDefaultIndex, prtMediaPathMaxSpeedPrintUnit, prtMediaPathMediaSizeUnit, prtMediaPathMaxSpeed, prtMediaPathMaxMediaFeedDir, prtMediaPathMaxMediaXFeedDir, prtMediaPathMinMediaFeedDir, prtMediaPathMinMediaXFeedDir, prtMediaPathType, prtMediaPathDescription, prtMediaPathStatus} STATUS current DESCRIPTION "The media path group." ::= { prtMIBGroups 13 } prtChannelGroup OBJECT-GROUP OBJECTS { prtChannelType, prtChannelProtocolVersion, prtChannelCurrentJobCntlLangIndex, prtChannelDefaultPageDescLangIndex, prtChannelState, prtChannelIfIndex, prtChannelStatus } STATUS current DESCRIPTION "The channel group." ::= { prtMIBGroups 14 } prtInterpreterGroup OBJECT-GROUP OBJECTS { prtInterpreterLangFamily, prtInterpreterLangLevel, prtInterpreterLangVersion, prtInterpreterDescription, prtInterpreterVersion, prtInterpreterDefaultOrientation, prtInterpreterFeedAddressability, prtInterpreterXFeedAddressability, prtInterpreterDefaultCharSetIn, prtInterpreterDefaultCharSetOut, prtInterpreterTwoWay } STATUS current DESCRIPTION "The interpreter group." ::= { prtMIBGroups 15 } prtConsoleGroup OBJECT-GROUP OBJECTS { prtConsoleLocalization, prtConsoleNumberOfDisplayLines, prtConsoleNumberOfDisplayChars, prtConsoleDisable, prtConsoleDisplayBufferText, prtConsoleOnTime, prtConsoleOffTime, prtConsoleColor, prtConsoleDescription } STATUS current DESCRIPTION "The console group." ::= { prtMIBGroups 16 } prtAlertTableGroup OBJECT-GROUP OBJECTS { prtAlertSeverityLevel, prtAlertTrainingLevel, prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, prtAlertCode, prtAlertDescription } STATUS current DESCRIPTION "The alert table group." ::= { prtMIBGroups 17 } prtAlertTimeGroup OBJECT-GROUP OBJECTS { prtAlertTime } STATUS current DESCRIPTION "The alert time group." ::= { prtMIBGroups 18 } END