#pragma namespace("\\\\.\\root")
instance of __namespace
{
Name = "pchealth";
};
#pragma namespace("\\\\.\\root\\pchealth")
instance of __Win32Provider as $DataProv
{
Name = "MS_VIEW_INSTANCE_PROVIDER";
ClsId = "{AA70DDF4-E11C-11D1-ABB0-00C04FD9159E}";
ImpersonationLevel = 1;
PerUserInitialization = "True";
};
instance of __InstanceProviderRegistration
{
Provider = $DataProv;
SupportsGet = True;
SupportsDelete = True;
SupportsEnumeration = True;
QuerySupportLevels = {"WQL:UnarySelect"};
};
instance of __MethodProviderRegistration
{
Provider = $DataProv;
};
//______________________________________________________________________________
//
// Name: PCH_ProgramGroup
// Synopsis: This is a View class.
// Mapped from Win32_ProgramGroup.
// Source Properties : GroupName, Name, UserName
// View Properties : Groupname, Name, UserName
// There is a change property a string with constant
// value = "SnapShot". This is required for delta computation.
// Missing Data: None
// Additional Data: None
// Created By: kalyanin
//______________________________________________________________________________
[
union,
ViewSources {"select GroupName, Name, UserName FROM Win32_ProgramGroup"},
ViewSpaces ("\\\\.\\root\\cimv2"),
dynamic, provider("MS_VIEW_INSTANCE_PROVIDER")
]
class PCH_ProgramGroup
{
[PropertySources{"GroupName"}]
string GroupName;
[key, PropertySources{"Name"}]
string Name;
[PropertySources{"UserName"}]
string UserName;
[PropertySources{""}]
string Change = "SnapShot";
};
//______________________________________________________________________________
//
// Name: PCH_NetWorkConnection
// Synopsis: This is a View class.
// Mapped from Win32_NetworkConnection.
// Source Properties : Name, LocalName, RemoteName,
// ResourceType, Status
// View Properties : Name, LocalName, RemoteName,
// Type, Status
// There is a change property a string with constant
// value = "SnapShot". This is required for delta computation.
// Missing Data: None
// Additional Data: Name
// Reasons: Name is a "key" property in win32_NetworkConnection
// class. All Key properties from the source class
// need to be present in the view class.
// Created By: kalyanin
//______________________________________________________________________________
[
union,
ViewSources {"select Name, LocalName, RemoteName, ResourceType, Status FROM Win32_NetworkConnection"},
ViewSpaces ("\\\\.\\root\\cimv2"),
dynamic, provider("MS_VIEW_INSTANCE_PROVIDER")
]
class PCH_NetworkConnection
{
[key, PropertySources{"Name"}]
string Name;
[PropertySources{"LocalName"}]
string LocalName;
[PropertySources{"RemoteName"}]
string RemoteName;
[PropertySources{"ResourceType"}]
string Type;
[PropertySources{"Status"}]
string Status;
[PropertySources{""}]
string Change = "SnapShot";
};
//______________________________________________________________________________
//
// Name: PCH_PrintJob
// Synopsis: This is a View class.
// Mapped from Win32_PrintJob.
// Source Properties : Name, Size, Status,
// TimeSubmitted, PagesPrinted
// View Properties : Name, Size, Status,
// TimeSubmitted, PagesPrinted
// There is a change property a string with constant
// value = "SnapShot". This is required for delta computation.
// Missing Data: None
// Additional Data: None
// Created By: kalyanin
//______________________________________________________________________________
[
union,
ViewSources {"select Name, Size, Status, TimeSubmitted, PagesPrinted FROM Win32_PrintJob"},
ViewSpaces ("\\\\.\\root\\cimv2"),
dynamic, provider("MS_VIEW_INSTANCE_PROVIDER")
]
class PCH_PrintJob
{
[key, PropertySources{"Name"}]
string Name;
[PropertySources{"Size"}]
Uint32 Size;
[PropertySources{"Status"}]
string Status;
[PropertySources{"TimeSubmitted"}]
DateTime TimeSubmitted;
[PropertySources{"PagesPrinted"}]
Uint32 PagesPrinted;
[PropertySources{""}]
string Change = "SnapShot";
};
//______________________________________________________________________________
//
// Name: PCH_NetworkProtocol
// Synopsis: This is a View class.
// Mapped from Win32_NetworkProtocol.
// Source Properties : Name, ConnectionlessService,
// GuaranteesDelivery,GuaranteesSequencing
// View Properties : Name, ConnectionlessService,
// GuaranteesDelivery, GuaranteesSequencing
// There is a change property a string with constant
// value = "SnapShot". This is required for delta computation.
// Missing Data: None
// Additional Data: None
// Created By: kalyanin
//______________________________________________________________________________
[
union,
ViewSources {"select Name, ConnectionlessService, GuaranteesDelivery, GuaranteesSequencing from Win32_NetworkProtocol"},
ViewSpaces ("\\\\.\\root\\cimv2"),
dynamic, provider("MS_VIEW_INSTANCE_PROVIDER")
]
class PCH_NetworkProtocol
{
[key, PropertySources{"Name"}]
string Name;
[PropertySources{"ConnectionLessService"}]
boolean ConnectionLessService ;
[PropertySources{"GuaranteesDelivery"}]
boolean GuaranteesDelivery;
[PropertySources{"GuaranteesSequencing"}]
boolean GuaranteesSequencing;
[PropertySources{""}]
string Change = "SnapShot";
};
//______________________________________________________________________________
//
// Name: PCH_Drive
// Synopsis: This is a View class.
// Mapped from Win32_LogicalDisk.
// Source Properties : DeviceID, FileSystem,
// FreeSpace, Size
// View Properties : DriveLetter, FileSystemType,
// FreeBytes, AvailBytes
// There is a change property a string with constant
// value = "SnapShot". This is required for delta computation.
// Missing Data: None
// Additional Data: None
// Created By: kalyanin
//______________________________________________________________________________
[ Union,
ViewSources {"select DeviceID, FileSystem, FreeSpace, Size FROM win32_LogicalDisk"},
ViewSpaces ("\\\\.\\root\\cimv2"),
dynamic, provider("MS_VIEW_INSTANCE_PROVIDER")
]
class PCH_Drive
{
[key, PropertySources{"DeviceID"}]
string DriveLetter;
[PropertySources{"FileSystem"}]
string FileSystemType ;
[PropertySources{"FreeSpace"}]
uint64 FreeBytes;
[PropertySources{"Size"}]
uint64 AvailBytes;
[PropertySources{""}]
string Change = "SnapShot";
};
//-----------------------------------------------------------------------------
// Created by : a-jammar
// Date : 04/14/1999
// Sypnosis : This creates a view class to map Win32_CODECFile.
// What we call "category" is the "group" field from
// Win32_CODECFile. What we call "group" is a registry
// key grouping the CODECs, and isn't in Win32_CODECFile.
//
// NOTE: SELECT * used because "Group" is a keyword.
//
// Missing data : Group, Key
//-----------------------------------------------------------------------------
[
union,
ViewSources {"SELECT * FROM Win32_CODECFile"},
ViewSpaces ("\\\\.\\root\\cimv2"),
dynamic, provider("MS_VIEW_INSTANCE_PROVIDER")
]
class PCH_CODEC
{
[PropertySources{""}]
string Change = "SnapShot";
[PropertySources{"description"}]
string Description;
[key, PropertySources{"name"}]
string CODECDriver;
[PropertySources{"version"}]
string Version;
[PropertySources{"group"}]
string Category;
[PropertySources{"creationdate"}]
datetime Date;
[PropertySources{"filesize"}]
uint64 SizeBytes;
[PropertySources{""}, Description("MISSING DATA")]
string Group = "MISSING";
[PropertySources{""}, Description("MISSING DATA")]
string Key = "MISSING";
};
//-----------------------------------------------------------------------------
// Created by : a-jammar
// Date : 04/06/1999
// Sypnosis : This creates a view class to map Win32_CDROMDrive.
// NOTE: TotalSpaceKB replaced with TotalSpace.
// NOTE: Removing the "device" property?
//
// Missing data : TransferFile, TransferSizeBytes, CPUUtilAt300KBS,
// IntegrityFile, IntegritySize, device(registry)
//-----------------------------------------------------------------------------
[
union,
ViewSources {"SELECT DeviceID, Drive, VolumeName, TransferRate, DriveIntegrity, "
"Description, SCSITargetId, Manufacturer, MaxMediaSize FROM Win32_CDROMDrive"},
ViewSpaces ("\\\\.\\root\\cimv2"),
dynamic, provider("MS_VIEW_INSTANCE_PROVIDER")
]
class PCH_CDROM
{
[PropertySources{""}]
string Change = "SnapShot";
[key, PropertySources{"DeviceID"}] // new property - a key in source class
string DeviceID;
[key, PropertySources{"Drive"}]
string DriveLetter;
[PropertySources{"VolumeName"}]
string VolumeName;
[PropertySources{"MaxMediaSize"}]
uint64 TotalSpace;
[PropertySources{"TransferRate"}]
real64 TransferRateKBS;
[PropertySources{"DriveIntegrity"}]
boolean DataTransferIntegrity;
[PropertySources{"Description"}]
string Description;
[PropertySources{"SCSITargetId"}]
uint16 SCSI;
[PropertySources{"Manufacturer"}]
string Manufacturer;
[PropertySources{""}, Description("MISSING DATA")]
string TransferFile = "MISSING";
[PropertySources{""}, Description("MISSING DATA")]
uint64 TransferSizeBytes = 0;
[PropertySources{""}, Description("MISSING DATA")]
uint32 CPUUtilAt300KBS = 0;
[PropertySources{""}, Description("MISSING DATA")]
string IntegrityFile = "MISSING";
[PropertySources{""}, Description("MISSING DATA")]
uint64 IntegritySize = 0;
};
//-----------------------------------------------------------------------------
// Created by : a-jammar
// Date : 04/06/1999
// Sypnosis : This creates a view class for startup items.
//
// Missing data : None.
//-----------------------------------------------------------------------------
[
union,
ViewSources {"SELECT User, Name, Location, Command FROM Win32_StartupCommand"},
ViewSpaces ("\\\\.\\root\\cimv2"),
dynamic, provider("MS_VIEW_INSTANCE_PROVIDER")
]
class PCH_Startup
{
[PropertySources{""}]
string Change = "SnapShot";
[key, PropertySources{"User"}] // new property - a key in source class
string User;
[key, PropertySources{"Name"}]
string Name;
[key, PropertySources{"Location"}]
string LoadedFrom;
[key, PropertySources{"Command"}]
string Command;
};
//-----------------------------------------------------------------------------
// Created by : a-jammar
// Date : 04/14/1999
// Sypnosis : This creates a view class to show RUNNING TASK.
// Note that this class uses two queries and a join between
// the cimv2 classes. The order of the strings is very
// important in the ViewSources, ViewSpaces and
// PropertySources constructs. The first string in the
// ViewSpaces corresponds to the namespace for the first
// SELECT in ViewSources. When specifying the properties
// in PropertySources, the first string corresponds to the
// results of the first SELECT, the second to the second
// SELECT.
//
// Missing data : PartOf, Address
//-----------------------------------------------------------------------------
[
JoinOn("Win32_Process.ExecutablePath = CIM_DataFile.Name"),
ViewSources {"SELECT Caption, ExecutablePath, Handle FROM Win32_Process",
"SELECT Name, Version, Description, Manufacturer, CreationDate FROM CIM_DataFile"},
ViewSpaces {"\\\\.\\root\\cimv2", "\\\\.\\root\\cimv2"},
dynamic, provider("MS_VIEW_INSTANCE_PROVIDER"),
EnumerateClasses{"Win32_Process"}
]
class PCH_RunningTask
{
[PropertySources{"", ""}]
string Change = "SnapShot";
[PropertySources{"Caption", ""}]
string Name;
[key, PropertySources{"ExecutablePath", "Name"}]
string Path;
[key, PropertySources{"Handle", ""}] // new property - a key in source class
string Handle;
[PropertySources{"", "Version"}]
string Version;
[PropertySources{"", "Description"}]
string Description;
[PropertySources{"", "Manufacturer"}]
string Manufacturer;
[PropertySources{"", "CreationDate"}]
datetime Date;
[PropertySources{"", ""}, Description("MISSING DATA")]
string PartOf = "MISSING";
[PropertySources{"", ""}, Description("MISSING DATA")]
string Address = "MISSING";
};