Source code of Windows XP (NT5)
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

267 lines
6.0 KiB

/*++
Copyright (c) 1999 Microsoft Corporation
Module Name:
Shutdown.c
Abstract:
This module contains the server side implementation for the Win32 remote
shutdown APIs, that is:
- BaseInitiateSystemShutdown
- BaseAbortSystemShutdown
- BaseInitiateSystemShutdownEx
Author:
Dragos C. Sambotin 18-May-1999
Notes:
These server side APIs are just stubs RPCalling in the winlogon's shutdown
interface. They are provided only for backward compatibility. When support
for older versions is dropped, these stubs can be removed.
Revision History:
--*/
#define UNICODE
#include <rpc.h>
#include "regrpc.h"
#include "shutinit.h"
#include "..\regconn\regconn.h"
ULONG
BaseInitiateSystemShutdown(
IN PREGISTRY_SERVER_NAME ServerName,
IN PUNICODE_STRING lpMessage OPTIONAL,
IN DWORD dwTimeout,
IN BOOLEAN bForceAppsClosed,
IN BOOLEAN bRebootAfterShutdown
)
/*++
Routine Description:
This routine is provided for backward compatibility. It does nothing
Arguments:
ServerName - Name of machine this server code is running on. (Ignored)
lpMessage - message to display during shutdown timeout period.
dwTimeout - number of seconds to delay before shutting down
bForceAppsClosed - Normally applications may prevent system shutdown.
- If this true, all applications are terminated unconditionally.
bRebootAfterShutdown - TRUE if the system should reboot. FALSE if it should
- be left in a shutdown state.
Return Value:
Returns ERROR_SUCCESS (0) for success; error-code for failure.
--*/
{
DWORD Result;
SHUTDOWN_CONTEXT ShutdownContext;
RPC_STATUS RpcStatus ;
//
// If we are here, we have been called by an NT4 or Win9x machine
// which doesn't know about the new interface
//
//
// Explicitly bind to the given server.
//
if (!ARGUMENT_PRESENT(ServerName)) {
return ERROR_SUCCESS;
}
RpcStatus = RpcImpersonateClient( NULL );
if ( RpcStatus != 0 )
{
return RpcStatus ;
}
//
// do it locally
//
ServerName = L"";
ShutdownContext.dwTimeout = dwTimeout;
ShutdownContext.bForceAppsClosed = (bForceAppsClosed != 0);
ShutdownContext.bRebootAfterShutdown = (bRebootAfterShutdown != 0);
//
// delegate the call to the new interface
//
Result = BaseBindToMachineShutdownInterface(ServerName,
NewShutdownCallback,
lpMessage,
&ShutdownContext);
RevertToSelf();
return Result;
}
ULONG
BaseInitiateSystemShutdownEx(
IN PREGISTRY_SERVER_NAME ServerName,
IN PUNICODE_STRING lpMessage OPTIONAL,
IN DWORD dwTimeout,
IN BOOLEAN bForceAppsClosed,
IN BOOLEAN bRebootAfterShutdown,
IN DWORD dwReason
)
/*++
Routine Description:
This routine is provided for backward compatibility. It does nothing
Arguments:
ServerName - Name of machine this server code is running on. (Ignored)
lpMessage - message to display during shutdown timeout period.
dwTimeout - number of seconds to delay before shutting down
bForceAppsClosed - Normally applications may prevent system shutdown.
- If this true, all applications are terminated unconditionally.
bRebootAfterShutdown - TRUE if the system should reboot. FALSE if it should
- be left in a shutdown state.
dwReason - Reason for initiating the shutdown. This reason is logged
in the eventlog #6006 event.
Return Value:
Returns ERROR_SUCCESS (0) for success; error-code for failure.
--*/
{
DWORD Result;
SHUTDOWN_CONTEXTEX ShutdownContext;
RPC_STATUS RpcStatus ;
//
// If we are here, we have been called by an NT4 or Win9x machine
// which doesn't know about the new interface
//
//
// Explicitly bind to the given server.
//
if (!ARGUMENT_PRESENT(ServerName)) {
return ERROR_SUCCESS;
}
RpcStatus = RpcImpersonateClient( NULL );
if ( RpcStatus != 0 )
{
return RpcStatus ;
}
// do it locally
ServerName = L"";
ShutdownContext.dwTimeout = dwTimeout;
ShutdownContext.bForceAppsClosed = (bForceAppsClosed != 0);
ShutdownContext.bRebootAfterShutdown = (bRebootAfterShutdown != 0);
ShutdownContext.dwReason = dwReason;
//
// delegate the call to the new interface
//
Result = BaseBindToMachineShutdownInterface(ServerName,
NewShutdownCallbackEx,
lpMessage,
&ShutdownContext);
RevertToSelf();
return Result;
}
ULONG
BaseAbortSystemShutdown(
IN PREGISTRY_SERVER_NAME ServerName
)
/*++
Routine Description:
This routine is provided for backward compatibility. It does nothing
Arguments:
ServerName - Name of machine this server code is running on. (Ignored)
Return Value:
Returns ERROR_SUCCESS (0) for success; error-code for failure.
--*/
{
DWORD Result;
RPC_BINDING_HANDLE binding;
RPC_STATUS RpcStatus ;
//
// If we are here, we have been called by an NT4 or Win9x machine
// which doesn't know about the new interface
//
//
// Explicitly bind to the given server.
//
if (!ARGUMENT_PRESENT(ServerName)) {
return ERROR_SUCCESS;
}
//
// Call the server
//
RpcStatus = RpcImpersonateClient( NULL );
if ( RpcStatus != 0 )
{
return RpcStatus ;
}
// do it locally
ServerName = L"";
//
// delegate the call to the new interface
//
Result = BaseBindToMachineShutdownInterface(ServerName,
NewAbortShutdownCallback,
NULL,
NULL);
RevertToSelf();
return Result;
}