mirror of https://github.com/tongzx/nt5src
You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
395 lines
12 KiB
395 lines
12 KiB
REM
|
|
REM Generate msrdpcli.msi from msrdpcl_.msi
|
|
REM 1) create data.cab for client bins and stream that in
|
|
REM 2) stream in custom.dll (custom action)
|
|
REM 3) Update file table with new version and size info (for this build)
|
|
REM 4) Update product and package code for this build (every build is like a 'new product')
|
|
REM
|
|
REM Assumes i386 build env (we don't build tsclient MSI for any other archs)
|
|
REM Contact: nadima
|
|
REM
|
|
|
|
REM (need this switch for the BuildNum stuff below to work)
|
|
setlocal ENABLEDELAYEDEXPANSION
|
|
|
|
set MSIIDTDIR=%_NTPOSTBLD%\tsclient\win32\i386\idtdir
|
|
set MSINAME=.\msrdpcli.msi
|
|
|
|
REM make tempdirs
|
|
if exist .\tmpcab (
|
|
rmdir /q /s .\tmpcab
|
|
if errorlevel 1 call errmsg.cmd "err deleting tmpcab dir"& goto errend
|
|
)
|
|
if exist %MSIIDTDIR% (
|
|
rmdir /q /s %MSIIDTDIR%
|
|
if errorlevel 1 call errmsg.cmd "err deleting idtdir dir"& goto errend
|
|
)
|
|
|
|
mkdir .\tmpcab
|
|
if errorlevel 1 call errmsg.cmd "err creating .\tmpcab dir"& goto errend
|
|
|
|
mkdir %MSIIDTDIR%
|
|
if errorlevel 1 call errmsg.cmd "err creating %MSIIDTDIR% dir"& goto errend
|
|
|
|
|
|
REM verify source files
|
|
if not exist .\mstscax.dll (
|
|
call errmsg.cmd "mstscax.dll is missing for tscmsigen.cmd"
|
|
goto errend
|
|
)
|
|
if not exist .\mstsc.exe (
|
|
call errmsg.cmd "mstsc.exe is missing for tscmsigen.cmd"
|
|
goto errend
|
|
)
|
|
|
|
if not exist %_NTPOSTBLD%\mstsc.chm (
|
|
call errmsg.cmd "mstsc.chm is missing for tscmsigen.cmd"
|
|
goto errend
|
|
)
|
|
|
|
copy %_NTPOSTBLD%\mstsc.chm .\mstsc.chm
|
|
if errorlevel 1 call errmsg.cmd "err copying up help (mstsc.chm) from binaries root"& goto errend
|
|
|
|
if not exist .\msrdpcl_.msi (
|
|
call errmsg.cmd "msrdpcl_.msi is missing for tscmsigen.cmd"
|
|
goto errend
|
|
)
|
|
if not exist .\custom.dll (
|
|
call errmsg.cmd "custom.dll is missing for tscmsigen.cmd"
|
|
goto errend
|
|
)
|
|
if not exist .\wistream.vbs (
|
|
call errmsg.cmd "wistream.vbs is missing for tscmsigen.cmd"
|
|
goto errend
|
|
)
|
|
if not exist .\media.idt (
|
|
call errmsg.cmd "media.idt is missing for tscmsigen.cmd"
|
|
goto errend
|
|
)
|
|
|
|
|
|
REM rename files
|
|
copy .\mstsc.exe .\tmpcab\F1060_mstsc.exe
|
|
if errorlevel 1 call errmsg.cmd "err copying files to .\tmpcab"& goto errend
|
|
copy .\mstsc.chm .\tmpcab\F1061_mstsc.chm
|
|
if errorlevel 1 call errmsg.cmd "err copying files to .\tmpcab"& goto errend
|
|
copy .\mstscax.dll .\tmpcab\F1059_mstscax.dll
|
|
if errorlevel 1 call errmsg.cmd "err copying files to .\tmpcab"& goto errend
|
|
|
|
REM now generate the cab file
|
|
if exist .\data.cab (
|
|
del data.cab
|
|
)
|
|
REM Sequence of files MUST match Sequence field of MSI File table (see Sequence property in File table)
|
|
cabarc -s 6144 -m MSZIP -i 1 n .\data.cab .\tmpcab\F1060_mstsc.exe .\tmpcab\F1059_mstscax.dll .\tmpcab\F1061_mstsc.chm
|
|
if errorlevel 1 (
|
|
call errmsg.cmd "cabarc failed to generate .\data.cab"
|
|
goto errend
|
|
)
|
|
|
|
rmdir /q /s .\tmpcab
|
|
if errorlevel 1 call errmsg.cmd "err deleting tmpcab dir"& goto errend
|
|
|
|
REM *****************************************************
|
|
REM * Update the MSI *
|
|
REM *****************************************************
|
|
if exist %MSINAME% del %MSINAME%
|
|
copy .\msrdpcl_.msi msrdpcli.msi
|
|
if errorlevel 1 call errmsg.cmd "err copying msrdpcl_.msi to %MSINAME%" & goto errend
|
|
|
|
REM *****************************************************
|
|
REM * Stream in the client binaries (in cab form) *
|
|
REM *****************************************************
|
|
cscript.exe .\wistream.vbs %MSINAME% .\data.cab
|
|
if errorlevel 1 (
|
|
call errmsg.cmd "wistream failed to stream in .\data.cab"
|
|
goto errend
|
|
)
|
|
|
|
REM *****************************************************
|
|
REM * Stream in the update custom.dll *
|
|
REM *****************************************************
|
|
cscript.exe .\wistream.vbs %MSINAME% .\custom.dll Binary.New_Binary
|
|
if errorlevel 1 (
|
|
call errmsg.cmd "wistream failed to stream in .\custom.dll"
|
|
goto errend
|
|
)
|
|
|
|
REM *****************************************************
|
|
REM * Give every package that gets generated, a new *
|
|
REM * product and package code. MSI will always thing *
|
|
REM * its upgrading. *
|
|
REM *****************************************************
|
|
|
|
call :UpdateProductCode %MSINAME% %MSIIDTDIR%
|
|
call :UpdatePackageCode %MSINAME% %MSIIDTDIR%
|
|
call :SetUpgradeCode %MSINAME% %MSIIDTDIR%
|
|
|
|
REM *****************************************************
|
|
REM * Update the product version property *
|
|
REM *****************************************************
|
|
call :SetVersion %MSINAME% %MSIIDTDIR%
|
|
|
|
|
|
REM *****************************************************
|
|
REM * Update the filetable with file size and ver info *
|
|
REM * assumes the source files are in the same directory*
|
|
REM *****************************************************
|
|
call cscript.exe .\\wifilver.vbs /U %MSINAME%
|
|
if errorlevel 1 (
|
|
call errmsg.cmd "wifilver failed"
|
|
goto errend
|
|
)
|
|
REM *****************************************************
|
|
REM * Update the media table to reflect that the data.cab
|
|
REM * is a streamed in archive *
|
|
REM *****************************************************
|
|
copy .\media.idt %MSIIDTDIR%\media.idt
|
|
if errorlevel 1 call errmsg.cmd "err copying media.idt files to IDTDIR"& goto errend
|
|
|
|
call cscript.exe .\wiimport.vbs %MSINAME% %MSIIDTDIR% media.idt
|
|
if errorlevel 1 (
|
|
call errmsg.cmd "Import update media table failed"
|
|
goto errend
|
|
)
|
|
|
|
REM *****************************************************
|
|
REM * Patch the Control table to fix dev src lock problems
|
|
REM *****************************************************
|
|
msiquery.exe "UPDATE Control Set Attributes = 3 WHERE Type = 'RadioButtonGroup'" %MSINAME%
|
|
|
|
call logmsg.cmd "tscmsigen.cmd COMPLETED OK!"
|
|
REM we're done
|
|
endlocal
|
|
goto end
|
|
|
|
REM ******************SUBS START HERE********************
|
|
|
|
REM *****************************************************
|
|
REM * Update version sub *
|
|
REM * (updates version in the property table *
|
|
REM *****************************************************
|
|
|
|
:SetVersion
|
|
|
|
REM
|
|
REM Update the version in the Property table
|
|
REM and update the version in the Upgrade Table
|
|
REM
|
|
REM %1 is the msi file
|
|
REM %2 is the msiidt directory
|
|
|
|
set ntverp=%_NTBINDIR%\public\sdk\inc\ntverp.h
|
|
if NOT EXIST %ntverp% (echo Can't find ntverp.h.&goto :ErrEnd)
|
|
|
|
for /f "tokens=3 delims=, " %%i in ('findstr /c:"#define VER_PRODUCTMAJORVERSION " %ntverp%') do (
|
|
set /a ProductMajor="%%i"
|
|
set BuildNum=%%i
|
|
)
|
|
|
|
for /f "tokens=3 delims=, " %%i in ('findstr /c:"#define VER_PRODUCTMINORVERSION " %ntverp%') do (
|
|
set /a ProductMinor="%%i"
|
|
set BuildNum=!BuildNum!.%%i
|
|
)
|
|
|
|
for /f "tokens=6" %%i in ('findstr /c:"#define VER_PRODUCTBUILD " %ntverp%') do (
|
|
set /a ProductBuild="%%i"
|
|
set BuildNum=!BuildNum!.%%i
|
|
)
|
|
|
|
for /f "tokens=3" %%i in ('findstr /c:"#define VER_PRODUCTBUILD_QFE " %ntverp%') do (
|
|
set /a ProductQfe="%%i"
|
|
set BuildNum=!BuildNum!.%%i
|
|
)
|
|
|
|
|
|
call logmsg.cmd "Updating the msrdpcli.msi ProductVersion to !BuildNum! in prop table"
|
|
call cscript.exe .\\wiexport.vbs %1 %2 Property
|
|
|
|
copy %2\Property.idt %2\Property.idt.old > nul
|
|
del /f %2\Property.idt
|
|
|
|
for /f "tokens=1,2,* delims= " %%a in (%2\Property.idt.old) do (
|
|
if /i "%%a" == "ProductVersion" (
|
|
echo %%a !BuildNum!>>%2\Property.idt
|
|
) else (
|
|
if "%%c"=="" (
|
|
echo %%a %%b>>%2\Property.idt
|
|
) else (
|
|
echo %%a %%b %%c>>%2\Property.idt
|
|
)
|
|
)
|
|
)
|
|
|
|
REM Set the property that says if this is an x86 or a 64-bit package
|
|
if /i "%CurArch%" == "i386" (
|
|
echo Install32 ^1>>%2\Property.idt
|
|
)
|
|
if /i "%CurArch%" == "ia64" (
|
|
echo Install64 ^1>>%2\Property.idt
|
|
)
|
|
|
|
call cscript.exe .\\wiimport.vbs //nologo %1 %2 Property.idt
|
|
if errorlevel 1 (
|
|
call errmsg.cmd "Import of Property table in SetVersion back into msrdpcli.msi failed!"
|
|
goto errend
|
|
)
|
|
REM call logmsg.cmd "Finished updating the ProductVersion in the property table"
|
|
|
|
goto :EOF
|
|
|
|
|
|
REM *****************************************************
|
|
REM * Update product code sub *
|
|
REM *****************************************************
|
|
|
|
:UpdateProductCode
|
|
|
|
REM Update the product code GUID in the property table
|
|
REM
|
|
REM %1 is the msi file
|
|
REM %2 is the msi idt directory
|
|
|
|
call logmsg.cmd "Updating the product code GUID in the property table"
|
|
call cscript.exe .\\wiexport.vbs %1 %2 Property
|
|
|
|
copy %2\Property.idt %2\Property.idt.old > nul
|
|
del /f %2\Property.idt
|
|
|
|
uuidgen.exe -c -o%2\productguid
|
|
for /f "tokens=1" %%a in (%2\productguid) do (
|
|
set NewGuid=%%a
|
|
)
|
|
|
|
call logmsg.cmd "ProductCode GUID = !NewGuid!"
|
|
|
|
for /f "tokens=1,2,* delims= " %%a in (%2\Property.idt.old) do (
|
|
if /i "%%a" == "ProductCode" (
|
|
echo %%a {%NewGuid%}>>%2\Property.idt
|
|
) else (
|
|
if "%%c"=="" (
|
|
echo %%a %%b>>%2\Property.idt
|
|
) else (
|
|
echo %%a %%b %%c>>%2\Property.idt
|
|
)
|
|
)
|
|
)
|
|
|
|
call cscript.exe .\wiimport.vbs //nologo %1 %2 Property.idt
|
|
if errorlevel 1 (
|
|
call errmsg.cmd "Import of Property table in UpdateProductCode back into msrdpcli.msi failed!"
|
|
goto errend
|
|
)
|
|
call logmsg.cmd "Finished updating the product code GUID in the property table"
|
|
|
|
goto :EOF
|
|
|
|
REM *****************************************************
|
|
REM * Update package code sub *
|
|
REM *****************************************************
|
|
|
|
:UpdatePackageCode
|
|
|
|
REM
|
|
REM Update the guid for the package code in the _SummaryInformation table
|
|
REM %1 is the msi file
|
|
REM %2 is the msiidt directory
|
|
|
|
call logmsg.cmd "Updating the package code GUID in the _SummaryInformation table"
|
|
call cscript.exe .\\wiexport.vbs //nologo %1 %2 _SummaryInformation
|
|
|
|
copy %2\_SummaryInformation.idt %2\_SummaryInformation.idt.old > nul
|
|
del /f %2\_SummaryInformation.idt
|
|
|
|
uuidgen.exe -c -o%2\packageguid
|
|
for /f "tokens=1" %%a in (%2\packageguid) do (
|
|
set NewGuid=%%a
|
|
)
|
|
|
|
call logmsg.cmd "ProductCode GUID (package code) = !NewGuid!"
|
|
|
|
for /f "tokens=1,2 delims= " %%a in (%2\_SummaryInformation.idt.old) do (
|
|
if "%%a" == "9" (
|
|
echo %%a {%NewGuid%}>>%2\_SummaryInformation.idt
|
|
) else (
|
|
echo %%a %%b>>%2\_SummaryInformation.idt
|
|
)
|
|
)
|
|
|
|
call cscript.exe .\\wiimport.vbs //nologo %1 %2 _SummaryInformation.idt
|
|
|
|
goto :EOF
|
|
|
|
|
|
REM *****************************************************
|
|
REM * Set upgrade code to ease future upgrades *
|
|
REM *****************************************************
|
|
|
|
:SetUpgradeCode
|
|
|
|
REM Update the upgrade code GUID in the property table
|
|
REM
|
|
REM %1 is the msi file
|
|
REM %2 is the msi idt directory
|
|
|
|
call logmsg.cmd "Setting the upgrade code GUID in the property table"
|
|
call cscript.exe .\\wiexport.vbs //nologo %1 %2 Property
|
|
|
|
copy %2\Property.idt %2\Property.idt.old > nul
|
|
del /f %2\Property.idt
|
|
|
|
set CurUpgradeGUID=17258378-2B69-4900-9754-1CAD4D0FB7CC
|
|
|
|
call logmsg.cmd "!CurArch! Upgrade Code GUID = !CurUpgradeGUID!"
|
|
|
|
for /f "tokens=1,2,* delims= " %%a in (%2\Property.idt.old) do (
|
|
if /i "%%a" == "UpgradeCode" (
|
|
echo %%a {!CurUpgradeGuid!}>>%2\Property.idt
|
|
) else (
|
|
if "%%c"=="" (
|
|
echo %%a %%b>>%2\Property.idt
|
|
) else (
|
|
echo %%a %%b %%c>>%2\Property.idt
|
|
)
|
|
)
|
|
)
|
|
|
|
call cscript.exe .\\wiimport.vbs //nologo %1 %2 Property.idt
|
|
if errorlevel 1 (
|
|
call errmsg.cmd "Import of Property table in SetUpgradeCode back into msrdpcli.msi failed!"
|
|
goto errend
|
|
)
|
|
call logmsg.cmd "Finished updating the product code GUID in the property table"
|
|
|
|
REM Update the upgrade code GUID in the Upgrade table
|
|
call logmsg.cmd "Updating the upgrade code in the Upgrade table
|
|
|
|
call cscript.exe .\\wiexport.vbs //nologo %1 %2 Upgrade
|
|
|
|
copy %2\Upgrade.idt %2\Upgrade.idt.old > nul
|
|
del /f %2\Upgrade.idt
|
|
|
|
REM
|
|
REM Put the header to the file
|
|
REM Echo the first three lines to the file
|
|
set /a count=1
|
|
for /f "tokens=*" %%a in (%2\upgrade.idt.old) do (
|
|
if !count! LEQ 3 echo %%a>>%2\Upgrade.idt
|
|
set /a count=!count!+1
|
|
)
|
|
|
|
for /f "skip=3 tokens=1,2,3,4,5,6* delims= " %%a in (%2\Upgrade.idt.old) do (
|
|
echo {!CurUpgradeGuid!} %%b %%c %%d %%e %%f>>%2\Upgrade.idt
|
|
)
|
|
|
|
call cscript.exe .\\wiimport.vbs //nologo %1 %2 Upgrade.idt
|
|
call logmsg.cmd "Finished updating the Upgrade code in the upgrade table"
|
|
goto :EOF
|
|
|
|
:errend
|
|
goto :EOF
|
|
|
|
:end
|
|
seterror.exe 0
|
|
goto :EOF
|
|
|