Source code of Windows XP (NT5)
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

193 lines
3.7 KiB

/*++
Copyright (c) 2000 Microsoft Corporation
Module Name:
IE5DOMSetup.cpp
Abstract:
This DLL fixes a problem with Internet Explorer's IE5DOM.EXE package. If
the command line contains /n:v, the package will replace the 128-bit
encryption modules that shipped with Win2K, which can cause serious harm -
no one can log on to the machine.
This shim simply removes /n:v from the command line so that the package
does not replace the encryption DLLs.
History:
02/01/2000 jarbats Created
--*/
#include "precomp.h"
IMPLEMENT_SHIM_BEGIN(IE5DOMSetup)
#include "ShimHookMacro.h"
APIHOOK_ENUM_BEGIN
APIHOOK_ENUM_END
VOID
StartSecondProcess(LPWSTR lpCommandLine)
{
PROCESS_INFORMATION ProcessInfo;
STARTUPINFOW StartupInfo;
LPWSTR FileName;
LPWSTR CurrentDir;
DWORD Size;
Size=GetCurrentDirectoryW(0,NULL);
CurrentDir=(LPWSTR)ShimMalloc(Size*sizeof(WCHAR));
if(NULL == CurrentDir)
{
//it is better to fail now then go on and bomb the system
ExitProcess(0);
}
GetCurrentDirectoryW(Size,CurrentDir);
FileName=(LPWSTR)ShimMalloc((MAX_PATH+2)*sizeof(WCHAR));
if(NULL == FileName)
{
ExitProcess(0);
}
GetModuleFileNameW(NULL, FileName, MAX_PATH+2);
StartupInfo.cb=sizeof(STARTUPINFO);
StartupInfo.lpReserved=NULL;
StartupInfo.lpDesktop=NULL;
StartupInfo.lpTitle=NULL;
StartupInfo.dwFlags=0;
StartupInfo.cbReserved2=0;
StartupInfo.lpReserved2=NULL;
CreateProcessW(
FileName,
lpCommandLine,
NULL,
NULL,
FALSE,
NORMAL_PRIORITY_CLASS,
NULL,
CurrentDir,
&StartupInfo,
&ProcessInfo
);
ExitProcess(0);
}
VOID CheckCommandLine()
{
LPWSTR lpCommandLine,lpNewCommandLine;
LPWSTR *lpArgV;
LPWSTR lpSwitch={L"/n:v"};
BOOL b;
INT nArgC=0;
DWORD nSwitch=1;
INT i, j;
lpCommandLine=GetCommandLineW();
if(NULL == lpCommandLine)
{
//without arguments this exe is harmless
return;
}
i = lstrlenW(lpCommandLine)+2;
lpNewCommandLine=(LPWSTR)ShimMalloc( i*sizeof(WCHAR) );
if(NULL == lpNewCommandLine)
{
ExitProcess(0);
}
lpArgV = _CommandLineToArgvW(lpCommandLine,&nArgC);
if(NULL == lpArgV)
{
//better to fail now
ExitProcess(0);
}
else
{
if( nArgC < 2)
{
//there isn't any chance for /n:v
ShimFree(lpNewCommandLine);
GlobalFree(lpArgV);
return;
}
}
b = FALSE;
for ( i=1; i<nArgC; i++ )
{
if(lstrcmpiW(lpArgV[i],lpSwitch))
{
wcscat(lpNewCommandLine,lpArgV[i]);
}
else
{
b = TRUE;
}
}
if (TRUE == b)
{
StartSecondProcess(lpNewCommandLine);
}
//never gets here because startsecondprocess doesn't return
}
/*++
Handle DLL_PROCESS_ATTACH and DLL_PROCESS_DETACH in your notify function
to do initialization and uninitialization.
IMPORTANT: Make sure you ONLY call NTDLL, KERNEL32 and MSVCRT APIs during
DLL_PROCESS_ATTACH notification. No other DLLs are initialized at that
point.
If your shim cannot initialize properly, return FALSE and none of the
APIs specified will be hooked.
--*/
BOOL
NOTIFY_FUNCTION(
DWORD fdwReason)
{
if (fdwReason == DLL_PROCESS_ATTACH)
{
CheckCommandLine();
}
return TRUE;
}
/*++
Register hooked functions
--*/
HOOK_BEGIN
CALL_NOTIFY_FUNCTION
HOOK_END