mirror of https://github.com/tongzx/nt5src
You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
924 lines
30 KiB
924 lines
30 KiB
|
|
/*****************************************************************************\
|
|
|
|
MAIN.CPP
|
|
|
|
Microsoft Confidential
|
|
Copyright (c) Microsoft Corporation 1998
|
|
All rights reserved
|
|
|
|
Contains...
|
|
|
|
1/99 - JCOHEN
|
|
Created main program file.
|
|
|
|
\*****************************************************************************/
|
|
|
|
#include "precomp.h"
|
|
#include "msobmain.h"
|
|
#include "setupkey.h"
|
|
#include "resource.h"
|
|
|
|
#define ICWDESKTOPCHANGED L"DesktopChanged"
|
|
#define MAX_MESSAGE_LEN 256
|
|
#define ICWSETTINGSPATH L"Software\\Microsoft\\Internet Connection Wizard"
|
|
#define ICW_REGKEYCOMPLETED L"Completed"
|
|
#define REGSTR_PATH_SETUPKEY REGSTR_PATH_SETUP REGSTR_KEY_SETUP
|
|
#define REGSTR_PATH_SYSTEMSETUPKEY L"System\\Setup"
|
|
#define REGSTR_VALUE_CMDLINE L"CmdLine"
|
|
#define REGSTR_VALUE_SETUPTYPE L"SetupType"
|
|
#define REGSTR_VALUE_MINISETUPINPROGRESS L"MiniSetupInProgress"
|
|
#define REGSTR_PATH_IEONDESKTOP REGSTR_PATH_IEXPLORER L"\\AdvancedOptions\\BROWSE\\IEONDESKTOP"
|
|
static const WCHAR g_szRegPathWelcomeICW[] = L"Welcome\\ICW";
|
|
static const WCHAR g_szAllUsers[] = L"All Users";
|
|
static const WCHAR g_szConnectApp[] = L"ICWCONN1.EXE";
|
|
static const WCHAR g_szConnectLink[] = L"Connect to the Internet";
|
|
static const WCHAR g_szOEApp[] = L"MSINM.EXE";
|
|
static const WCHAR g_szOELink[] = L"Outlook Express";
|
|
static const WCHAR g_szRegPathICWSettings[] = L"Software\\Microsoft\\Internet Connection Wizard";
|
|
static const WCHAR g_szRegValICWCompleted[] = L"Completed";
|
|
|
|
WCHAR g_szShellNext [MAX_PATH+1] = L"\0nogood";
|
|
WCHAR g_szShellNextParams [MAX_PATH+1] = L"\0nogood";
|
|
HINSTANCE g_hInstance = NULL;
|
|
|
|
/*******************************************************************
|
|
|
|
NAME: RegisterComObjects
|
|
|
|
SYNOPSIS: App entry point
|
|
|
|
********************************************************************/
|
|
BOOL SelfRegisterComObject(LPWSTR szDll, BOOL fRegister)
|
|
{
|
|
HINSTANCE hModule = LoadLibrary(szDll);
|
|
BOOL bRet = FALSE;
|
|
|
|
if (hModule)
|
|
{
|
|
HRESULT (STDAPICALLTYPE *pfn)(void);
|
|
|
|
if (fRegister)
|
|
(FARPROC&)pfn = GetProcAddress(hModule, REG_SERVER);
|
|
else
|
|
(FARPROC&)pfn = GetProcAddress(hModule, UNREG_SERVER);
|
|
|
|
if (pfn && SUCCEEDED((*pfn)()))
|
|
bRet = TRUE;
|
|
|
|
FreeLibrary(hModule);
|
|
}
|
|
|
|
return bRet;
|
|
}
|
|
|
|
|
|
// This undoes what DoDesktopChanges did
|
|
void UndoDesktopChanges()
|
|
{
|
|
|
|
WCHAR szConnectTotheInternetTitle[MAX_PATH];
|
|
HKEY hkey;
|
|
|
|
// Verify that we really changed the desktop
|
|
if (ERROR_SUCCESS == RegOpenKeyEx(HKEY_CURRENT_USER,
|
|
ICWSETTINGSPATH,
|
|
0,
|
|
KEY_ALL_ACCESS,
|
|
&hkey))
|
|
{
|
|
DWORD dwDesktopChanged = 0;
|
|
DWORD dwTmp = sizeof(DWORD);
|
|
DWORD dwType = 0;
|
|
|
|
if (ERROR_SUCCESS == RegQueryValueEx(hkey,
|
|
ICWDESKTOPCHANGED,
|
|
NULL,
|
|
&dwType,
|
|
(LPBYTE)&dwDesktopChanged,
|
|
&dwTmp))
|
|
{
|
|
}
|
|
RegCloseKey(hkey);
|
|
|
|
// Bail if the desktop was not changed by us
|
|
if(!dwDesktopChanged)
|
|
{
|
|
return;
|
|
}
|
|
}
|
|
|
|
// Always nuke the Connect to the internet icon
|
|
HINSTANCE hInst = LoadLibrary(OOBE_MAIN_DLL);
|
|
|
|
if (!LoadString(hInst,
|
|
IDS_CONNECT_DESKTOP_TITLE,
|
|
szConnectTotheInternetTitle,
|
|
MAX_CHARS_IN_BUFFER(szConnectTotheInternetTitle)))
|
|
{
|
|
lstrcpy(szConnectTotheInternetTitle, g_szConnectLink);
|
|
}
|
|
|
|
RemoveDesktopShortCut(szConnectTotheInternetTitle);
|
|
}
|
|
|
|
void StartIE
|
|
(
|
|
LPWSTR lpszURL
|
|
)
|
|
{
|
|
WCHAR szIEPath[MAX_PATH];
|
|
HKEY hkey;
|
|
|
|
// first get the app path
|
|
if (RegOpenKeyEx(HKEY_LOCAL_MACHINE,
|
|
REGSTR_PATH_APPPATHS,
|
|
0,
|
|
KEY_READ,
|
|
&hkey) == ERROR_SUCCESS)
|
|
{
|
|
|
|
DWORD dwTmp = sizeof(szIEPath);
|
|
if(RegQueryValue(hkey, L"iexplore.exe", szIEPath, (PLONG)&dwTmp) != ERROR_SUCCESS)
|
|
{
|
|
ShellExecute(NULL, L"open",szIEPath,lpszURL,NULL,SW_NORMAL);
|
|
}
|
|
else
|
|
{
|
|
ShellExecute(NULL, L"open",L"iexplore.exe",lpszURL,NULL,SW_NORMAL);
|
|
|
|
}
|
|
RegCloseKey(hkey);
|
|
}
|
|
else
|
|
{
|
|
ShellExecute(NULL, L"open",L"iexplore.exe",lpszURL,NULL,SW_NORMAL);
|
|
}
|
|
|
|
}
|
|
|
|
void HandleShellNext()
|
|
{
|
|
DWORD dwVal = 0;
|
|
DWORD dwSize = sizeof(dwVal);
|
|
HKEY hKey = NULL;
|
|
|
|
if(RegOpenKeyEx(HKEY_CURRENT_USER,
|
|
ICWSETTINGSPATH,
|
|
0,
|
|
KEY_ALL_ACCESS,
|
|
&hKey) == ERROR_SUCCESS)
|
|
{
|
|
RegQueryValueEx(hKey,
|
|
ICW_REGKEYCOMPLETED,
|
|
0,
|
|
NULL,
|
|
(LPBYTE)&dwVal,
|
|
&dwSize);
|
|
|
|
RegCloseKey(hKey);
|
|
}
|
|
|
|
if (dwVal)
|
|
{
|
|
TRACE3(L"Starting IE because HKCU\\%s\\%s = %d", ICWSETTINGSPATH, ICW_REGKEYCOMPLETED, dwVal);
|
|
|
|
UndoDesktopChanges();
|
|
|
|
if (PathIsURL(g_szShellNext))
|
|
{
|
|
TRACE1(L"Navigating to %s", g_szShellNext);
|
|
StartIE(g_szShellNext);
|
|
}
|
|
else if(g_szShellNext[0] != L'\0')
|
|
{
|
|
// Let the shell deal with it
|
|
TRACE1(L"ShellExecuting %s", g_szShellNext);
|
|
ShellExecute(NULL, L"open",g_szShellNext,g_szShellNextParams,NULL,SW_NORMAL);
|
|
}
|
|
}
|
|
}
|
|
|
|
|
|
//+----------------------------------------------------------------------------
|
|
//
|
|
// Function: GetShellNextFromReg
|
|
//
|
|
// Synopsis: Reads the ShellNext key from the registry, and then parses it
|
|
// into a command and parameter. This key is set by
|
|
// SetShellNext in inetcfg.dll in conjunction with
|
|
// CheckConnectionWizard.
|
|
//
|
|
// Arguments: none
|
|
//
|
|
// Returns: none
|
|
//
|
|
// History: jmazner 7/9/97 Olympus #9170
|
|
//
|
|
//-----------------------------------------------------------------------------
|
|
BOOL GetShellNextFromReg
|
|
(
|
|
LPWSTR lpszCommand,
|
|
LPWSTR lpszParams
|
|
)
|
|
{
|
|
BOOL fRet = TRUE;
|
|
WCHAR szShellNextCmd [MAX_PATH] = L"\0";
|
|
DWORD dwShellNextSize = sizeof(szShellNextCmd);
|
|
LPWSTR lpszTemp = NULL;
|
|
HKEY hkey = NULL;
|
|
|
|
if( !lpszCommand || !lpszParams )
|
|
{
|
|
return FALSE;
|
|
}
|
|
|
|
if ((RegOpenKey(HKEY_CURRENT_USER, ICWSETTINGSPATH, &hkey)) == ERROR_SUCCESS)
|
|
{
|
|
if (RegQueryValueEx(hkey,
|
|
L"ShellNext",
|
|
NULL,
|
|
NULL,
|
|
(BYTE *)szShellNextCmd,
|
|
(DWORD *)&dwShellNextSize) != ERROR_SUCCESS)
|
|
{
|
|
fRet = FALSE;
|
|
goto GetShellNextFromRegExit;
|
|
}
|
|
}
|
|
else
|
|
{
|
|
fRet = FALSE;
|
|
goto GetShellNextFromRegExit;
|
|
}
|
|
|
|
//
|
|
// This call will parse the first token into lpszCommand, and set szShellNextCmd
|
|
// to point to the remaining tokens (these will be the parameters). Need to use
|
|
// the pszTemp var because GetCmdLineToken changes the pointer's value, and we
|
|
// need to preserve lpszShellNextCmd's value so that we can GlobalFree it later.
|
|
//
|
|
lpszTemp = szShellNextCmd;
|
|
GetCmdLineToken( &lpszTemp, lpszCommand );
|
|
|
|
lstrcpy( lpszParams, lpszTemp );
|
|
|
|
//
|
|
// it's possible that the shellNext command was wrapped in quotes for
|
|
// parsing purposes. But since ShellExec doesn't understand quotes,
|
|
// we now need to remove them.
|
|
//
|
|
if( L'"' == lpszCommand[0] )
|
|
{
|
|
//
|
|
// get rid of the first quote
|
|
// note that we're shifting the entire string beyond the first quote
|
|
// plus the terminating NULL down by one byte.
|
|
//
|
|
memmove( lpszCommand, &(lpszCommand[1]), BYTES_REQUIRED_BY_SZ(lpszCommand) );
|
|
|
|
//
|
|
// now get rid of the last quote
|
|
//
|
|
lpszCommand[lstrlen(lpszCommand) - 1] = L'\0';
|
|
}
|
|
|
|
GetShellNextFromRegExit:
|
|
if (hkey)
|
|
RegCloseKey(hkey);
|
|
return fRet;
|
|
}
|
|
|
|
|
|
//+----------------------------------------------------------------------------
|
|
//
|
|
// Function: RemoveShellNextFromReg
|
|
//
|
|
// Synopsis: deletes the ShellNext reg key if present. This key is set by
|
|
// SetShellNext in inetcfg.dll in conjunction with
|
|
// CheckConnectionWizard.
|
|
//
|
|
// Arguments: none
|
|
//
|
|
// Returns: none
|
|
//
|
|
// History: jmazner 7/9/97 Olympus #9170
|
|
//
|
|
//-----------------------------------------------------------------------------
|
|
void RemoveShellNextFromReg( void )
|
|
{
|
|
HKEY hkey;
|
|
|
|
if ((RegOpenKey(HKEY_CURRENT_USER, ICWSETTINGSPATH, &hkey)) == ERROR_SUCCESS)
|
|
{
|
|
RegDeleteValue(hkey, L"ShellNext");
|
|
RegCloseKey(hkey);
|
|
}
|
|
}
|
|
|
|
//GetShellNext
|
|
//
|
|
// 5/21/97 jmazner Olympus #4157
|
|
// usage: /shellnext c:\path\executeable [parameters]
|
|
// the token following nextapp will be shellExec'd at the
|
|
// end of the "current" path. It can be anything that the shell
|
|
// knows how to handle -- an .exe, a URL, etc.. If executable
|
|
// name contains white space (eg: c:\program files\foo.exe), it
|
|
// should be wrapped in double quotes, "c:\program files\foo.exe"
|
|
// This will cause us to treat it as a single token.
|
|
//
|
|
// all consecutive subsequent tokens will
|
|
// be passed to ShellExec as the parameters until a token is
|
|
// encountered of the form /<non-slash character>. That is to say,
|
|
// the character combination // will be treated as an escape character
|
|
//
|
|
// this is easiest to explain by way of examples.
|
|
//
|
|
// examples of usage:
|
|
//
|
|
// icwconn1.exe /shellnext "C:\prog files\wordpad.exe" file.txt
|
|
// icwconn1.exe /prod IE /shellnext msimn.exe /promo MCI
|
|
// icwconn1.exe /shellnext msimn.exe //START_MAIL /promo MCI
|
|
//
|
|
// the executeable string and parameter string are limited to
|
|
// a length of MAX_PATH
|
|
//
|
|
BOOL GetShellNextToken(LPWSTR szCmdLine, LPWSTR szOut)
|
|
{
|
|
if (lstrcmpi(szOut, CMD_SHELLNEXT)==0)
|
|
{
|
|
// next token is expected to be white space
|
|
GetCmdLineToken(&szCmdLine, szOut);
|
|
|
|
if (szOut[0])
|
|
{
|
|
ZeroMemory(g_szShellNext, sizeof(g_szShellNext));
|
|
ZeroMemory(g_szShellNextParams, sizeof(g_szShellNextParams));
|
|
|
|
// Read white space
|
|
GetCmdLineToken(&szCmdLine, szOut);
|
|
//this should be the thing to ShellExec
|
|
if(*szCmdLine != L'/')
|
|
{
|
|
// watch closely, this gets a bit tricky
|
|
//
|
|
// if this command begins with a double quote, assume it ends
|
|
// in a matching quote. We do _not_ want to store the
|
|
// quotes, however, since ShellExec doesn't parse them out.
|
|
if( L'"' != szOut[0] )
|
|
{
|
|
// no need to worry about any of this quote business
|
|
lstrcpy( g_szShellNext, szOut );
|
|
}
|
|
else
|
|
{
|
|
lstrcpy( g_szShellNext, &szOut[1] );
|
|
g_szShellNext[lstrlen(g_szShellNext) - 1] = L'\0';
|
|
}
|
|
TRACE1(L"g_szShellNext = %s", g_szShellNext);
|
|
|
|
// now read in everything up to the next command line switch
|
|
// and consider it to be the parameter. Treat the sequence
|
|
// "//" as an escape sequence, and allow it through.
|
|
// Example:
|
|
// the token /whatever is considered to be a switch to
|
|
// icwconn1, and thus will break us out of the whle loop.
|
|
//
|
|
// the token //something is should be interpreted as a
|
|
// command line /something to the the ShellNext app, and
|
|
// should not break us out of the while loop.
|
|
GetCmdLineToken(&szCmdLine, szOut);
|
|
while( szOut[0] )
|
|
{
|
|
if( L'/' == szOut[0] )
|
|
{
|
|
if( L'/' != szOut[1] )
|
|
{
|
|
// it's not an escape sequence, so we're done
|
|
break;
|
|
}
|
|
else
|
|
{
|
|
// it is an escape sequence, so store it in
|
|
// the parameter list, but remove the first /
|
|
lstrcat( g_szShellNextParams, &szOut[1] );
|
|
}
|
|
}
|
|
else
|
|
{
|
|
lstrcat( g_szShellNextParams, szOut );
|
|
}
|
|
|
|
GetCmdLineToken(&szCmdLine, szOut);
|
|
}
|
|
TRACE1(L"g_szShellNextParams = %s", g_szShellNextParams);
|
|
return TRUE;
|
|
}
|
|
}
|
|
}
|
|
return FALSE;
|
|
|
|
}
|
|
|
|
void ParseCommandLine(LPTSTR lpszCmdParam, APMD *pApmd, DWORD *pProp, int *pRmdIndx)
|
|
{
|
|
if(lpszCmdParam && pApmd && pProp && pRmdIndx)
|
|
{
|
|
WCHAR szOut[MAX_PATH];
|
|
GetCmdLineToken(&lpszCmdParam, szOut);
|
|
|
|
while (szOut[0])
|
|
{
|
|
if (0 == lstrcmpi(szOut, CMD_FULLSCREENMODE))
|
|
{ // For now, full screen => OEM OOBE mode
|
|
*pProp |= (PROP_FULLSCREEN | PROP_OOBE_OEM);
|
|
*pApmd = APMD_OOBE;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_RETAIL))
|
|
{ // retail => full screen => OOBE mode
|
|
*pProp |= PROP_FULLSCREEN;
|
|
*pProp &= ~PROP_OOBE_OEM;
|
|
*pApmd = APMD_OOBE;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_PRECONFIG))
|
|
{
|
|
*pApmd = APMD_MSN;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_OFFLINE))
|
|
{
|
|
*pApmd = APMD_MSN;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_SETPWD))
|
|
{
|
|
*pProp |= PROP_SETCONNECTIOD;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_OOBE))
|
|
{
|
|
*pApmd = APMD_OOBE;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_REG))
|
|
{
|
|
*pApmd = APMD_REG;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_ISP))
|
|
{
|
|
*pApmd = APMD_ISP;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_ACTIVATE))
|
|
{
|
|
*pApmd = APMD_ACT;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_1))
|
|
{
|
|
*pRmdIndx = 1;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_2))
|
|
{
|
|
*pRmdIndx = 2;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_3))
|
|
{
|
|
*pRmdIndx = 3;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_MSNMODE))
|
|
{
|
|
*pApmd = APMD_MSN;
|
|
*pProp |= PROP_CALLFROM_MSN;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_ICWMODE))
|
|
{
|
|
*pApmd = APMD_MSN;
|
|
}
|
|
else if (GetShellNextToken(lpszCmdParam, szOut))
|
|
{
|
|
//*pApmd = APMD_DEFAULT;
|
|
}
|
|
else if (0 == lstrcmpi(szOut, CMD_2NDINSTANCE))
|
|
{
|
|
*pProp |= PROP_2NDINSTANCE;
|
|
}
|
|
|
|
GetCmdLineToken(&lpszCmdParam, szOut);
|
|
}
|
|
}
|
|
}
|
|
|
|
void AutoActivation()
|
|
{
|
|
// See if we are in an unattend case
|
|
WCHAR File [MAX_PATH*2] = L"\0";
|
|
DWORD dwExit;
|
|
BOOL AutoActivate = FALSE;
|
|
|
|
TRACE( L"Starting AutoActivation");
|
|
if (GetCanonicalizedPath(File, INI_SETTINGS_FILENAME))
|
|
{
|
|
TRACE1( L"GetCanonicalizedPath: %s",File);
|
|
if (GetPrivateProfileInt(OPTIONS_SECTION,
|
|
L"IntroOnly",
|
|
0,
|
|
File) > 0)
|
|
{
|
|
TRACE( L"Found intro Only");
|
|
AutoActivate = TRUE;
|
|
}
|
|
}
|
|
if (AutoActivate)
|
|
{
|
|
// Since we did intro only call autoactivation. it checks
|
|
// if it should run.
|
|
ExpandEnvironmentStrings(
|
|
TEXT("%SystemRoot%\\System32\\oobe\\oobebaln.exe /S"),
|
|
File,
|
|
sizeof(File)/sizeof(WCHAR));
|
|
|
|
TRACE1( L"Launching:%s", File);
|
|
// Launch and wait.
|
|
// I tried without wait and the activation did not succeed.
|
|
InvokeExternalApplicationEx(NULL, File, &dwExit, INFINITE, TRUE);
|
|
}
|
|
TRACE( L"AutoActivation done");
|
|
}
|
|
|
|
VOID
|
|
RunFactory(
|
|
)
|
|
{
|
|
TCHAR szFileName[MAX_PATH + 32] = TEXT("");
|
|
DWORD dwExit;
|
|
|
|
|
|
if ( ( ExpandEnvironmentStrings(
|
|
TEXT("%SystemDrive%\\sysprep\\factory.exe"),
|
|
szFileName,
|
|
sizeof(szFileName) / sizeof(TCHAR)) == 0 ) ||
|
|
( szFileName[0] == TEXT('\0') ) ||
|
|
( GetFileAttributes(szFileName) == 0xFFFFFFFF ) )
|
|
{
|
|
// If this fails, there is nothing we can really do.
|
|
//
|
|
TRACE( L"Factory.exe not found");
|
|
|
|
} else {
|
|
|
|
InvokeExternalApplicationEx(
|
|
szFileName,
|
|
L"-oobe",
|
|
&dwExit,
|
|
INFINITE,
|
|
TRUE
|
|
);
|
|
}
|
|
}
|
|
|
|
void RemoveIntroOnly()
|
|
{
|
|
WCHAR File [MAX_PATH*2] = L"\0";
|
|
if (GetCanonicalizedPath(File, INI_SETTINGS_FILENAME))
|
|
{
|
|
WritePrivateProfileString(OPTIONS_SECTION,
|
|
L"IntroOnly",
|
|
L"0",
|
|
File);
|
|
}
|
|
}
|
|
|
|
INT WINAPI LaunchMSOOBE(HINSTANCE hInstance, HINSTANCE hPrevInstance, LPWSTR lpszCmdParam, INT nCmdShow)
|
|
{
|
|
HANDLE Mutex;
|
|
BOOL bRegisteredDlls = FALSE;
|
|
BOOL bUseOleUninitialize = FALSE;
|
|
int iReturn=1;
|
|
APMD Apmd = APMD_DEFAULT;
|
|
DWORD Prop = 0;
|
|
int RmdIndx = 0;
|
|
|
|
|
|
//
|
|
// We can't use TRACE() until this is called, so don't put anything before it.
|
|
//
|
|
SetupOobeInitDebugLog();
|
|
TRACE1( L"OOBE run with the following parameters: %s", lpszCmdParam );
|
|
|
|
OOBE_SHUTDOWN_ACTION osa = SHUTDOWN_NOACTION;
|
|
|
|
g_hInstance = hInstance;
|
|
|
|
// Parse the command line early. The out params are passed to CObMain to
|
|
// set the private members.
|
|
ParseCommandLine(lpszCmdParam, &Apmd, &Prop, &RmdIndx);
|
|
|
|
// If we are not the 2nd instance
|
|
if (!(Prop & PROP_2NDINSTANCE))
|
|
{
|
|
CheckDigitalID();
|
|
|
|
if (Apmd == APMD_OOBE) {
|
|
|
|
CSetupKey setupkey;
|
|
|
|
MYASSERT(setupkey.IsValid());
|
|
if ( Prop & PROP_OOBE_OEM ) {
|
|
// Remove IntroOnly, just in case it is still set from the original install.
|
|
RemoveIntroOnly();
|
|
|
|
// reset the SetupType so that OOBe can be restarted (OEM case)
|
|
if (ERROR_SUCCESS != setupkey.set_SetupType(SETUPTYPE_NOREBOOT)) {
|
|
return FALSE;
|
|
}
|
|
} else {
|
|
|
|
//
|
|
// In the retail OOBE case, clean up the registry early, in case we
|
|
// fail to run to completion for some reason. We need to make sure
|
|
// we get rid of the OobeInProgress key.
|
|
//
|
|
CleanupForLogon(setupkey);
|
|
}
|
|
}
|
|
|
|
// If we are the first instance, do the checking and register the DLLs
|
|
// If we are the 2nd instance this is not needed.
|
|
//Exit if MSN app window is aready running and push that window to front
|
|
HWND hWnd = FindWindow(OOBE_MAIN_CLASSNAME, NULL);
|
|
if(hWnd != NULL)
|
|
{
|
|
SetForegroundWindow(hWnd);
|
|
if (IsIconic(hWnd))
|
|
SendMessage(hWnd, WM_SYSCOMMAND, SC_RESTORE, NULL);
|
|
|
|
TRACE(L"OOBE is already running in this session.");
|
|
return 0;
|
|
}
|
|
|
|
// It's possible that OOBE is running in another session. If so, we need
|
|
// to bail out.
|
|
Mutex = CreateMutex( NULL, TRUE, TEXT("Global\\OOBE is running") );
|
|
if ( !Mutex || GetLastError() == ERROR_ALREADY_EXISTS ) {
|
|
|
|
WCHAR szTitle [MAX_PATH] = L"\0";
|
|
WCHAR szMsg [MAX_PATH] = L"\0";
|
|
|
|
HINSTANCE hInst = GetModuleHandle(OOBE_MAIN_DLL);
|
|
|
|
TRACE(L"OOBE is already running in another session.");
|
|
|
|
if(hInst) {
|
|
LoadString(hInst, IDS_APPNAME, szTitle, MAX_CHARS_IN_BUFFER(szTitle));
|
|
LoadString(hInst, IDS_ALREADY_RUNNING, szMsg, MAX_CHARS_IN_BUFFER(szMsg));
|
|
|
|
MessageBox( NULL, szMsg, szTitle, MB_OK | MB_ICONEXCLAMATION | MB_APPLMODAL );
|
|
}
|
|
if ( Mutex ) {
|
|
CloseHandle( Mutex );
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
if(!SelfRegisterComObject(OOBE_WEB_DLL, TRUE)) {
|
|
TRACE(L"SelfRegisterComObject() failed.");
|
|
return 1;
|
|
}
|
|
|
|
if(!SelfRegisterComObject(OOBE_SHELL_DLL, TRUE)) {
|
|
TRACE(L"SelfRegisterComObject() failed.");
|
|
return 1;
|
|
}
|
|
|
|
if(!SelfRegisterComObject(OOBE_COMM_DLL, TRUE)) {
|
|
TRACE(L"SelfRegisterComObject() failed.");
|
|
return 1;
|
|
}
|
|
bRegisteredDlls = TRUE;
|
|
}
|
|
|
|
//If CoInit fails something is seriously messed up, run away
|
|
if (!(Prop & PROP_FULLSCREEN))
|
|
{
|
|
bUseOleUninitialize = TRUE;
|
|
// Need to use OleInitialize to get Clipboard support or Ctrl+C (Copy) does not work
|
|
// in the edit controls on the OOBE pages.
|
|
if(FAILED(OleInitialize(NULL))) {
|
|
TRACE(L"OleInitialize() failed.");
|
|
return 1;
|
|
}
|
|
|
|
}
|
|
else
|
|
{
|
|
// Don't have the support in fullscreen OOBE.
|
|
if(FAILED(CoInitialize(NULL))) {
|
|
TRACE(L"CoInitialize() failed.");
|
|
return 1;
|
|
}
|
|
}
|
|
|
|
|
|
{
|
|
// DO NOT REMOVE THIS SCOPE BLOCK. It controls the scope of ObMain.
|
|
// ObMain must be initialized after CoInitialize is called and
|
|
// destroyed prior to calling CoUninitialize.
|
|
//
|
|
CObMain ObMain(Apmd, Prop, RmdIndx);
|
|
|
|
// If we are the 1st instance or
|
|
// if we are the second instance and we are in OOBE mode and in fullscreen mode
|
|
if (!ObMain.Is2ndInstance() ||
|
|
(ObMain.Is2ndInstance() && ObMain.FHasProperty(PROP_OOBE_OEM)))
|
|
{
|
|
// If not in safe mode proceed.
|
|
//
|
|
if (!InSafeMode())
|
|
{
|
|
BOOL fOemOobeMode = ObMain.InOobeMode() && ObMain.FHasProperty(PROP_OOBE_OEM);
|
|
|
|
// Start the fullscreen background
|
|
//
|
|
if (!ObMain.Is2ndInstance() && ObMain.FFullScreen())
|
|
{
|
|
ObMain.CreateBackground();
|
|
}
|
|
|
|
// Run factory.exe if we're in OEM mode.
|
|
//
|
|
if (fOemOobeMode && !ObMain.Is2ndInstance()) {
|
|
|
|
RunFactory();
|
|
}
|
|
|
|
// CObMain::Init contains critical initialization. DO NOT call any other
|
|
// CObMain methods prior to it.
|
|
//
|
|
if (ObMain.Init())
|
|
{
|
|
if (Prop & PROP_SETCONNECTIOD)
|
|
{
|
|
ObMain.SetConnectoidInfo();
|
|
}
|
|
else if ((osa = ObMain.DisplayReboot()) != SHUTDOWN_NOACTION)
|
|
{
|
|
// Either we ran minisetup or we're done.
|
|
//
|
|
if (osa == SHUTDOWN_REBOOT)
|
|
{
|
|
ObMain.PowerDown(TRUE);
|
|
}
|
|
}
|
|
else
|
|
{
|
|
if (!ObMain.Is2ndInstance())
|
|
{
|
|
// If we are the 1st instance, call syssetup
|
|
// and start the magnifier if needed.
|
|
// The 2nd instance does not need this.
|
|
|
|
SetupOobeInitPreServices( fOemOobeMode );
|
|
|
|
if (ObMain.FFullScreen())
|
|
{
|
|
WCHAR WinntPath[MAX_PATH];
|
|
WCHAR Answer[MAX_PATH];
|
|
|
|
// Check if we should run Magnifier
|
|
if(GetCanonicalizedPath(WinntPath, WINNT_INF_FILENAME))
|
|
{
|
|
if(GetPrivateProfileString( L"Accessibility",
|
|
L"AccMagnifier",
|
|
L"",
|
|
Answer,
|
|
sizeof(Answer)/sizeof(WCHAR),
|
|
WinntPath
|
|
))
|
|
{
|
|
if ( lstrcmpi( Answer, L"1") == 0)
|
|
{
|
|
InvokeExternalApplication(L"magnify.exe", L"", NULL);
|
|
}
|
|
}
|
|
}
|
|
|
|
}
|
|
}
|
|
else
|
|
{
|
|
//
|
|
// The first instance did the minisetup stuff, so
|
|
// we don't need to do it again.
|
|
//
|
|
SetupOobeInitPreServices(FALSE);
|
|
}
|
|
|
|
if(0 != ObMain.InitApplicationWindow())
|
|
{
|
|
// BUGBUG: Is the following true for NT?
|
|
// If we finish OOBE, we return 0 to let the machine boot,
|
|
// otherwise we return 1 and the machine shutsdown because
|
|
// the user canceled or there was a fatal error.
|
|
//
|
|
iReturn = ObMain.RunOOBE() ? 0 : 1;
|
|
}
|
|
|
|
if (!ObMain.InAuditMode())
|
|
{
|
|
// We need to remove this entry now, so ICWMAN (INETWIZ) does not
|
|
// pick it up later
|
|
RemoveShellNextFromReg();
|
|
|
|
HandleShellNext();
|
|
|
|
if (!ObMain.Is2ndInstance())
|
|
{
|
|
// Only the 1st instance can do this.
|
|
// it called SetupOobeInitPreServices
|
|
CSetupKey setupkey;
|
|
OOBE_SHUTDOWN_ACTION action;
|
|
|
|
// We want to clear the restart stuff before
|
|
// calling SetupOobeCleanup. SetupOobeCleanup
|
|
// enables System Restore, which creates a restore
|
|
// point immediately and the restore point would
|
|
// cause Winlogon to start OOBE.
|
|
|
|
ObMain.RemoveRestartStuff(setupkey);
|
|
|
|
// SHUTDOWN_POWERDOWN happens only if bad pid
|
|
// is entered or eula is declined. We don't want to call
|
|
// SetupOobeCleanup and enable system restore
|
|
// at this point. This has to be called after
|
|
// RemoveRestartStuff.
|
|
|
|
if ((setupkey.get_ShutdownAction(&action) != ERROR_SUCCESS) ||
|
|
(action != SHUTDOWN_POWERDOWN))
|
|
{
|
|
if (fOemOobeMode)
|
|
{
|
|
ObMain.CreateBackground();
|
|
SetupOobeCleanup( fOemOobeMode );
|
|
ObMain.StopBackgroundWindow();
|
|
}
|
|
else
|
|
{
|
|
SetupOobeCleanup( fOemOobeMode );
|
|
}
|
|
}
|
|
}
|
|
}
|
|
}
|
|
}
|
|
if (!ObMain.InAuditMode() && ObMain.FFullScreen())
|
|
{
|
|
// OOBE is done, let see if we should launch AutoActivation?
|
|
AutoActivation();
|
|
}
|
|
ObMain.Cleanup();
|
|
|
|
} else if (ObMain.InMode(APMD_ACT)) {
|
|
|
|
WCHAR szTitle [MAX_PATH] = L"\0";
|
|
WCHAR szMsg [MAX_PATH] = L"\0";
|
|
|
|
HINSTANCE hInst = GetModuleHandle(OOBE_MAIN_DLL);
|
|
|
|
TRACE(L"Desktop activation cannot be run in safe mode.");
|
|
|
|
if(hInst) {
|
|
LoadString(hInst, IDS_APPNAME, szTitle, MAX_CHARS_IN_BUFFER(szTitle));
|
|
LoadString(hInst, IDS_SAFEMODE, szMsg, MAX_CHARS_IN_BUFFER(szMsg));
|
|
|
|
MessageBox( NULL, szMsg, szTitle, MB_OK | MB_ICONEXCLAMATION | MB_APPLMODAL );
|
|
}
|
|
|
|
} else {
|
|
|
|
// we are in safemode and not running Activation.
|
|
// At least start the services.
|
|
SignalComputerNameChangeComplete();
|
|
}
|
|
}
|
|
// DO NOT REMOVE THIS SCOPE BLOCK. It controls the scope of ObMain.
|
|
// ObMain must be initialized after CoInitialize is called and
|
|
// destroyed prior to calling CoUninitialize.
|
|
//
|
|
}
|
|
|
|
if (bUseOleUninitialize)
|
|
{
|
|
OleUninitialize();
|
|
}
|
|
else
|
|
{
|
|
CoUninitialize();
|
|
}
|
|
|
|
if (bRegisteredDlls)
|
|
{
|
|
SelfRegisterComObject(OOBE_WEB_DLL, FALSE);
|
|
SelfRegisterComObject(OOBE_SHELL_DLL, FALSE);
|
|
SelfRegisterComObject(OOBE_COMM_DLL, FALSE);
|
|
CloseHandle( Mutex );
|
|
}
|
|
|
|
TRACE( L"OOBE has finished." );
|
|