Source code of Windows XP (NT5)
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

171 lines
5.3 KiB

;/*++ BUILD Version: 0001 // Increment this if a change has global effects
;
;Copyright (c) 1992, 1993 Microsoft Corporation
;
;Module Name:
;
; sermlog.mc
;
;Abstract:
;
; Constant definitions for the I/O error code log values.
;
;Revision History:
;
;--*/
;
;#ifndef _SERMLOG_
;#define _SERMLOG_
;
;//
;// Status values are 32 bit values layed out as follows:
;//
;// 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
;// 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
;// +---+-+-------------------------+-------------------------------+
;// |Sev|C| Facility | Code |
;// +---+-+-------------------------+-------------------------------+
;//
;// where
;//
;// Sev - is the severity code
;//
;// 00 - Success
;// 01 - Informational
;// 10 - Warning
;// 11 - Error
;//
;// C - is the Customer code flag
;//
;// Facility - is the facility code
;//
;// Code - is the facility's status code
;//
;
MessageIdTypedef=NTSTATUS
SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS
Informational=0x1:STATUS_SEVERITY_INFORMATIONAL
Warning=0x2:STATUS_SEVERITY_WARNING
Error=0x3:STATUS_SEVERITY_ERROR
)
FacilityNames=(System=0x0
RpcRuntime=0x2:FACILITY_RPC_RUNTIME
RpcStubs=0x3:FACILITY_RPC_STUBS
Io=0x4:FACILITY_IO_ERROR_CODE
Sermouse=0x5:FACILITY_SERMOUSE_ERROR_CODE
)
MessageId=0x0001 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_INSUFFICIENT_RESOURCES
Language=English
Not enough memory was available to allocate internal storage needed for the device %1.
.
MessageId=0x0002 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_NO_BUFFER_ALLOCATED
Language=English
Not enough memory was available to allocate the ring buffer that holds incoming data for %1.
.
MessageId=0x0003 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_REGISTERS_NOT_MAPPED
Language=English
The hardware locations for %1 could not be translated to something the memory management system understands.
.
MessageId=0x0004 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_RESOURCE_CONFLICT
Language=English
The hardware resources for %1 are already in use by another device.
.
MessageId=0x0005 Facility=Sermouse Severity=Informational SymbolicName=SERMOUSE_NOT_ENOUGH_CONFIG_INFO
Language=English
Some firmware configuration information was incomplete, so defaults were used.
.
MessageId=0x0006 Facility=Sermouse Severity=Informational SymbolicName=SERMOUSE_USER_OVERRIDE
Language=English
User configuration data is overriding firmware configuration data.
.
MessageId=0x0007 Facility=Sermouse Severity=Warning SymbolicName=SERMOUSE_NO_DEVICEMAP_CREATED
Language=English
Unable to create the device map entry for %1.
.
MessageId=0x0008 Facility=Sermouse Severity=Warning SymbolicName=SERMOUSE_NO_DEVICEMAP_DELETED
Language=English
Unable to delete the device map entry for %1.
.
MessageId=0x0009 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_NO_INTERRUPT_CONNECTED
Language=English
Could not connect the interrupt for %1.
.
MessageId=0x000A Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_INVALID_ISR_STATE
Language=English
The ISR has detected an internal state error in the driver for %1.
.
MessageId=0x000C Facility=Sermouse Severity=Informational SymbolicName=SERMOUSE_MOU_BUFFER_OVERFLOW
Language=English
The ring buffer that stores incoming mouse data has overflowed (buffer size is configurable via the registry).
.
MessageId=0x000D Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_INVALID_STARTIO_REQUEST
Language=English
The Start I/O procedure has detected an internal error in the driver for %1.
.
MessageId=0x000E Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_INVALID_INITIATE_STATE
Language=English
The Initiate I/O procedure has detected an internal state error in the driver for %1.
.
MessageId=0x0010 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_MOU_RESET_COMMAND_FAILED
Language=English
The mouse reset failed.
.
MessageId=0x0012 Facility=Sermouse Severity=Warning SymbolicName=SERMOUSE_MOU_RESET_RESPONSE_FAILED
Language=English
The device sent an incorrect response(s) following a mouse reset.
.
MessageId=0x0016 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_SET_SAMPLE_RATE_FAILED
Language=English
Could not set the mouse sample rate.
.
MessageId=0x0017 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_SET_RESOLUTION_FAILED
Language=English
Could not set the mouse resolution.
.
MessageId=0x0018 Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_MOU_ENABLE_XMIT
Language=English
Could not enable transmissions from the mouse.
.
MessageId=0x0019 Facility=Sermouse Severity=Warning SymbolicName=SERMOUSE_NO_SYMLINK_CREATED
Language=English
Unable to create the symbolic link for %1.
.
MessageId=0x001A Facility=Sermouse Severity=Warning SymbolicName=SERMOUSE_NO_SUCH_DEVICE
Language=English
The serial mouse does not exist or was not detected.
.
MessageId=0x001b Facility=Sermouse Severity=Informational SymbolicName=SERMOUSE_NOT_DETECTABLE
Language=English
Cannot detect surprise removal of the mouse on %1.
.
MessageId=0x001c Facility=Sermouse Severity=Error SymbolicName=SERMOUSE_ATTACH_DEVICE_FAILED
Language=English
Could not attach to the PnP device stack.
.
;#endif /* _SERMLOG_ */