mirror of https://github.com/tongzx/nt5src
You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
325 lines
9.9 KiB
325 lines
9.9 KiB
#include <windows.h>
|
|
#include <ntverp.h>
|
|
#include <winbase.h> // for GetCommandLine
|
|
#include "datasrc.h"
|
|
#include "autorun.h"
|
|
#include "util.h"
|
|
#include "resource.h"
|
|
|
|
//////////////////////////////////////////////////////////////////////
|
|
// Construction/Destruction
|
|
//////////////////////////////////////////////////////////////////////
|
|
|
|
CDataSource::CDataSource()
|
|
{
|
|
m_iItems = 0;
|
|
}
|
|
|
|
CDataSource::~CDataSource()
|
|
{
|
|
}
|
|
|
|
CDataItem & CDataSource::operator[](int i)
|
|
{
|
|
return m_data[m_piScreen[i]];
|
|
}
|
|
|
|
/*
|
|
10.05.96 Shunichi Kajisa (shunk) Support NEC PC-98
|
|
|
|
1. Determine if autorun is running on PC-98 or regular PC/AT by:
|
|
|
|
bNEC98 = (HIBYTE(LOWORD(GetKeyboardType(1))) == 0x0D)? TRUE : FALSE;
|
|
|
|
Following description is from KB Q130054, and this can be applied on NT and Win95:
|
|
|
|
If an application uses the GetKeyboardType API, it can get OEM ID by
|
|
specifying "1" (keyboard subtype) as argument of the function. Each OEM ID
|
|
is listed here:
|
|
|
|
OEM Windows OEM ID
|
|
------------------------------
|
|
Microsoft 00H (DOS/V)
|
|
....
|
|
NEC 0DH
|
|
|
|
|
|
2. If autorun is running on PC-98, replace every "I386" resource with "PC98" at runtime,
|
|
regardless that autorun is running on NT or Win95.
|
|
|
|
|
|
Notes:
|
|
- NEC PC-98 is available only in Japan.
|
|
- NEC PC-98 uses x86 processor, but the underlaying hardware architecture is different.
|
|
The PC98 files is stored under CD:\pc98 directory instead of CD:\i386.
|
|
- There was an idea that we should detect PC-98 in SHELL32.DLL, and treat PC98 as a different
|
|
platform, like having [AutoRun.Pc98] section in NT CD's autorun.inf. We don't do this, since
|
|
Win95 doesn't support this, and we don't want to introduce the apps incompatibility.
|
|
In any case, if app has any dependency on the hardware and needs to do any special things,
|
|
the app should detect the hardware and OS. This is separate issue from Autorun.exe.
|
|
|
|
*/
|
|
BOOL CDataSource::IsNec98()
|
|
{
|
|
return ((GetKeyboardType(0) == 7) && ((GetKeyboardType(1) & 0xff00) == 0x0d00));
|
|
}
|
|
|
|
// Init
|
|
//
|
|
// For autorun we read all the items out of the resources.
|
|
BOOL CDataSource::Init(LPSTR pszCommandLine)
|
|
{
|
|
// read the text for the items from the resources
|
|
HINSTANCE hinst = GetModuleHandle(NULL);
|
|
TCHAR szModuleName[MAX_PATH];
|
|
|
|
szModuleName[0] = TEXT('\0'); // in case GetModuleFileName fails to initialize szModuleName
|
|
GetModuleFileName(hinst, szModuleName, ARRAYSIZE(szModuleName)); // ex: "e:\i386\autorun.exe" or "e:\setup.exe"
|
|
PathRemoveFilespec(szModuleName); // ex: "e:\i386\" or "e:\"
|
|
PathAppend(szModuleName, TEXT("winnt32.exe")); //
|
|
|
|
if ( PathFileExists(szModuleName) )
|
|
{
|
|
// we were launched from the platform directory, use szModuleName as the winnt32 path
|
|
}
|
|
else
|
|
{
|
|
// we were launched from the root. Append either "alpha", "i386", or "NEC98" to the path.
|
|
SYSTEM_INFO si;
|
|
|
|
PathRemoveFilespec(szModuleName);
|
|
GetSystemInfo(&si);
|
|
|
|
#if !(defined(_X86_) || defined(_AMD64_) || defined(_IA64_))
|
|
#error New architecture must be added to switch statement.
|
|
#endif
|
|
switch (si.wProcessorArchitecture)
|
|
{
|
|
case PROCESSOR_ARCHITECTURE_AMD64:
|
|
{
|
|
PathAppend(szModuleName, TEXT("amd64\\winnt32.exe"));
|
|
}
|
|
break;
|
|
|
|
case PROCESSOR_ARCHITECTURE_IA64:
|
|
{
|
|
PathAppend(szModuleName, TEXT("ia64\\winnt32.exe"));
|
|
}
|
|
break;
|
|
|
|
case PROCESSOR_ARCHITECTURE_INTEL:
|
|
default:
|
|
{
|
|
if (IsNec98())
|
|
{
|
|
PathAppend(szModuleName, TEXT("nec98\\winnt32.exe"));
|
|
}
|
|
else
|
|
{
|
|
PathAppend(szModuleName, TEXT("i386\\winnt32.exe"));
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
}
|
|
|
|
for (int i=0; i<MAX_OPTIONS; i++)
|
|
{
|
|
TCHAR szTitle[256];
|
|
TCHAR szConfig[MAX_PATH];
|
|
TCHAR szArgs[MAX_PATH];
|
|
|
|
LoadStringAuto(hinst, IDS_TITLE0+i, szTitle, ARRAYSIZE(szTitle));
|
|
|
|
// for INSTALL_WINNT and COMPAT_LOCAL we prepend the correct path to winnt32 in front of the string
|
|
if ( INSTALL_WINNT == i || COMPAT_LOCAL == i)
|
|
{
|
|
lstrcpy( szConfig, szModuleName );
|
|
if ( !PathFileExists(szModuleName) )
|
|
{
|
|
// we can't run the item if it's not there. This will prevent an
|
|
// alpha CD from trying to install on an x86 and vice versa.
|
|
m_data[i].m_dwFlags |= WF_DISABLED|WF_ALTERNATECOLOR;
|
|
}
|
|
}
|
|
else
|
|
{
|
|
LoadStringAuto(hinst, IDS_CONFIG0+i, szConfig, ARRAYSIZE(szConfig));
|
|
}
|
|
|
|
|
|
if (INSTALL_WINNT == i) // for INSTALL_WINNT we pass through the command line args to setup.exe
|
|
{
|
|
lstrcpy (szArgs, pszCommandLine);
|
|
}
|
|
else if (BROWSE_CD == i) // for BROWSE_CD we pass the directory as an argument to explorer.exe
|
|
{
|
|
lstrcpy( szArgs, szModuleName );
|
|
PathRemoveFilespec( szArgs );
|
|
PathRemoveFilespec( szArgs );
|
|
}
|
|
else
|
|
{
|
|
LoadStringAuto(hinst, IDS_ARGS0+i, szArgs, ARRAYSIZE(szArgs));
|
|
}
|
|
|
|
|
|
m_data[i].SetData( szTitle, szConfig, *szArgs?szArgs:NULL, 0, i);
|
|
}
|
|
|
|
// Should we display the "This CD contains a newer version" dialog?
|
|
OSVERSIONINFO ovi;
|
|
ovi.dwOSVersionInfoSize = sizeof ( OSVERSIONINFO );
|
|
if ( !GetVersionEx(&ovi) || ovi.dwPlatformId==VER_PLATFORM_WIN32s )
|
|
{
|
|
// We cannot upgrade win32s systems.
|
|
m_Version = VER_INCOMPATIBLE;
|
|
}
|
|
else if ( ovi.dwPlatformId==VER_PLATFORM_WIN32_WINDOWS )
|
|
{
|
|
if (ovi.dwMajorVersion > 3)
|
|
{
|
|
// we can always upgrade win98+ systems to NT
|
|
m_Version = VER_OLDER;
|
|
|
|
// Disable ARP. ARP is only enabled if the CD and the OS are the same version
|
|
m_data[LAUNCH_ARP].m_dwFlags |= WF_DISABLED|WF_ALTERNATECOLOR;
|
|
}
|
|
else
|
|
{
|
|
m_Version = VER_INCOMPATIBLE;
|
|
}
|
|
}
|
|
else if ((MAJOR > ovi.dwMajorVersion) ||
|
|
((MAJOR == ovi.dwMajorVersion) && ((MINOR > ovi.dwMinorVersion) || ((MINOR == ovi.dwMinorVersion) && (BUILD > ovi.dwBuildNumber)))))
|
|
{
|
|
// For NT to NT upgrades, we only upgrade if the version is lower
|
|
|
|
// For NT 3.51 we have some special case code
|
|
if ( ovi.dwMajorVersion == 3 )
|
|
{
|
|
// must be at least NT 3.51
|
|
if ( ovi.dwMinorVersion < 51 )
|
|
{
|
|
// On NT 3.1 we might be able to launch winnt32.exe
|
|
STARTUPINFO sinfo =
|
|
{
|
|
sizeof(STARTUPINFO),
|
|
};
|
|
PROCESS_INFORMATION pinfo;
|
|
BOOL b = CreateProcess(NULL,szModuleName,NULL,NULL,FALSE,0,NULL,NULL,&sinfo,&pinfo);
|
|
if (b)
|
|
{
|
|
CloseHandle(pinfo.hProcess);
|
|
CloseHandle(pinfo.hThread);
|
|
}
|
|
|
|
return FALSE;
|
|
}
|
|
}
|
|
|
|
m_Version = VER_OLDER;
|
|
|
|
// Disable ARP. ARP is only enabled if the CD and the OS are the same version
|
|
m_data[LAUNCH_ARP].m_dwFlags |= WF_DISABLED|WF_ALTERNATECOLOR;
|
|
}
|
|
else if ((MAJOR < ovi.dwMajorVersion) || (MINOR < ovi.dwMinorVersion) || (BUILD < ovi.dwBuildNumber))
|
|
{
|
|
m_Version = VER_NEWER;
|
|
|
|
// disable upgrade and ARP buttons and associated things
|
|
m_data[INSTALL_WINNT].m_dwFlags |= WF_DISABLED|WF_ALTERNATECOLOR;
|
|
m_data[COMPAT_LOCAL].m_dwFlags |= WF_DISABLED|WF_ALTERNATECOLOR;
|
|
m_data[LAUNCH_ARP].m_dwFlags |= WF_DISABLED|WF_ALTERNATECOLOR;
|
|
}
|
|
else
|
|
{
|
|
m_Version = VER_SAME;
|
|
}
|
|
|
|
if (m_Version == VER_SAME)
|
|
{
|
|
m_piScreen = c_aiWhistler;
|
|
m_iItems = c_cWhistler;
|
|
}
|
|
else
|
|
{
|
|
m_piScreen = c_aiMain;
|
|
m_iItems = c_cMain;
|
|
}
|
|
|
|
return TRUE;
|
|
}
|
|
|
|
void CDataSource::Invoke( int i, HWND hwnd )
|
|
{
|
|
i = m_piScreen[i];
|
|
// if this item is disalbled then do nothing
|
|
if ( m_data[i].m_dwFlags & WF_DISABLED )
|
|
{
|
|
MessageBeep(0);
|
|
return;
|
|
}
|
|
|
|
// otherwise we have already built the correct command and arg strings so just invoke them
|
|
switch (i)
|
|
{
|
|
case INSTALL_WINNT:
|
|
case LAUNCH_ARP:
|
|
case BROWSE_CD:
|
|
case COMPAT_WEB:
|
|
case COMPAT_LOCAL:
|
|
case HOMENET_WIZ:
|
|
case MIGRATION_WIZ:
|
|
case TS_CLIENT:
|
|
case VIEW_RELNOTES:
|
|
case INSTALL_CLR:
|
|
m_data[i].Invoke(hwnd);
|
|
break;
|
|
case SUPPORT_TOOLS:
|
|
m_piScreen = c_aiSupport;
|
|
m_iItems = c_cSupport;
|
|
PostMessage(m_hwndDlg, ARM_CHANGESCREEN, SCREEN_TOOLS, 0);
|
|
break;
|
|
|
|
case COMPAT_TOOLS:
|
|
m_piScreen = c_aiCompat;
|
|
m_iItems = c_cCompat;
|
|
PostMessage(m_hwndDlg, ARM_CHANGESCREEN, SCREEN_COMPAT, 0);
|
|
break;
|
|
|
|
case BACK:
|
|
if (m_Version == VER_SAME)
|
|
{
|
|
m_piScreen = c_aiWhistler;
|
|
m_iItems = c_cWhistler;
|
|
}
|
|
else
|
|
{
|
|
m_piScreen = c_aiMain;
|
|
m_iItems = c_cMain;
|
|
}
|
|
PostMessage(m_hwndDlg, ARM_CHANGESCREEN, SCREEN_MAIN, 0);
|
|
break;
|
|
|
|
default:
|
|
// Assert? Debug trace message?
|
|
break;
|
|
}
|
|
}
|
|
|
|
// Uninit
|
|
//
|
|
// This is a chance to do any required shutdown stuff, such as persisting state information.
|
|
void CDataSource::Uninit(DWORD dwData)
|
|
{
|
|
}
|
|
|
|
// ShowSplashScreen
|
|
//
|
|
// This hook is provided to allow the display of additional UI right after the main window is diaplyed.
|
|
// In our case we want to show a dialog asking if the user wants to upgrade.
|
|
void CDataSource::ShowSplashScreen(HWND hwnd)
|
|
{
|
|
m_hwndDlg = hwnd;
|
|
}
|